TYPICAL WIRING DIAGRAM
NOTE: Larger versions of the Typical Wiring Diagrams are available in the products' operator manuals, refer to DSE
Publication: 057-310 DSE8910 Operator Manual & 057-311 DSE8920 Operator Manual, both available from
www.deepseaelectronics.com.
Deep Sea Electronics Ltd.
Tel: +44 (0)1723 890099
Email: support@deepseaelectronics.com
Web: www.deepseaelectronics.com
Deep Sea Electronics Inc.
Tel: +1 (815) 316 8706
Email: USAsupport@deepseaelectronics.com
Web: www.deepseaelectronics.com
D E E P S E A E L E C T R O N I C S
DSE8910 & DSE8920 Installation Instructions
ACCESSING THE MAIN CONFIGURATION EDITOR
NOTE: The available parameters within the Main Configuration Edtior differ depending if the DSE8910 or DSE8920 software
application is selected. For a list of available configuration parameters, refer to DSE Publication: 057-310 DSE8910 Operator
Manual & 057-311 DSE8920 Operator Manual, both available from www.deepseaelectronics.com.
Ensure the engine is at rest and the module by pressing the Stop/Reset Mode
button.
Press the Stop/Reset Mode
and Tick
buttons together to enter the main
configuration editor.
If a module security PIN has been set, the PIN request is then shown.
Press the Tick
button, the first '#' changes to '0'. Press the Up
Press the Right
button when the first digit is correctly entered. The digit previously entered now shows as '#' for security.
Repeat this process for the other digits of the PIN number. Press the Left
digits.
When the Tick
button is pressed after editing the final PIN digit, the PIN is checked for validity. If the number is not correct, the
PIN must be re-entered.
If the PIN has been successfully entered (or the module PIN has not been enabled), the editor is displayed.
ACCESSING THE RUNNING CONFIGURATION EDITOR
The Running Configuration Editor is accessible without stopping the generator. All protections remain active whilst the 'Running
Configuration Editor is accessed.
Press and hold the Tick
button to enter the Running Configuration Editor.
EDITING A PARAMETER
NOTE: If the editor is left inactive for the duration of the Page Timer, it is automatically exited to ensure security.
Enter either editor as described above.
Press the Up
or Down
buttons to select the section to view/change. The current selected section highlights in green.
Press the Left
or Right
buttons to select the Subsection/Parameter to be edited. The current selected item highlights in
green.
To edit the parameter, press the Tick
button to enter the edit mode. The parameter is no longer highlighted green to indicate
editing.
Press the Up
or Down
buttons to change the parameter to the required value.
Press the Tick
button to save the value. The parameter highlights green to indicate that it has been saved.
To exit the editor and save the changes, press and hold the Tick
SELECTING THE DSE8910 OR DSE8920 SOFTWARE APPLICATION
Ensure the generator is at rest and the module by pressing the Stop/Reset Mode
Enter the Running Configuration Editor as described above.
Press the Up
or Down
buttons to navigate to the MODEL TYPE section. The section highlights in green when selected.
Press the Right
button to select the MODEL SELECTION parameter. The parameter highlights in green when selected.
To edit the parameter, press the Tick
button to enter the edit mode. The parameter is no longer highlighted green to indicate
editing.
Press the Up
or Down
buttons to change between DSE8910 and DSE8920, by default DSE8920 is selected.
Press the Tick
button to change the software application, a confirmation box appears.
Press the Left
or Right
buttons to select YES to confirm software application change. When prompted, remove the power
supply to the module and then reapply the power supply. The module powers up in the newly selected software application.
053-248
ISSUE: 2
or Down
buttons to adjust it to the correct value.
button to move back to adjust one of the previous
button.
button.

Advertisement

loading

Summary of Contents for DEEP SEA ELECTRONICS DSE8910

  • Page 1 ACCESSING THE MAIN CONFIGURATION EDITOR NOTE: The available parameters within the Main Configuration Edtior differ depending if the DSE8910 or DSE8920 software application is selected. For a list of available configuration parameters, refer to DSE Publication: 057-310 DSE8910 Operator Manual &...