2-29. E: 95. Compressor motor control error (Outdoor unit)

Wired remote
Indicator
controller
Check point 1. Check Noise from Compressor
Turn on Power and check operation noise.
→ If an abnormal noise show, replace compres-
sor.
Check point 2. Check connection of around the compressor components
For compressor terminal, main PCB
Check if connector is removed.
Check erroneous connection.
Check if cable is open. (Refer to inverter compressor in
52.)
→ Upon correcting the removed connector or mis-wiring, reset the power.
Check point . Replace main PCB
If Check point do not improve the symptom, change main PCB.
Check point . Replace compressor
If Check point do not improve the symptom, change compressor.