Subsystem Details (Page 2 Of The Worksheet); Connection And Installation Considerations - IBM TotalStorage DS4000 Planning And Installation Manual

Alert manager appliance
Hide thumbs Also See for TotalStorage DS4000:
Table of Contents

Advertisement

Remote access permissions
Heartbeat access permissions

Subsystem details (page 2 of the worksheet)

The DS4000 Alert Manager Appliance can monitor up to four DS4000 storage
servers. If your initial installation monitors less than four storage servers, then you
can add monitoring for more storage servers in the future. (For more information,
see "Adding additional DS4000 storage servers to an existing DS4000 Alert
Manager Appliance configuration" on page 9.) Specify information about each of the
storage servers to be attached to the appliance in the table on page 2 of the
worksheet.
Attention:
server names used in IBM DS4000 Storage Manager.
Serial attachment cables are available in 16 ft. (4.8 m) and 50 ft. (15 m) lengths.
Indicate which length is needed to attach each storage server.
The "New or existing" column of the table is used when adding a new DS4000
storage server to an existing DS4000 Alert Manager Appliance. Indicate "Existing"
for the previously installed DS4000 storage server(s) and "New" for the storage
servers being added.
The following example shows sample details for three DS4000 storage servers.
Table 1. Subsystem details example
Machine type
1742-1RU
1722-6LU
1742-90U

Connection and installation considerations

The following connections are required when installing the DS4000 Alert Manager
Appliance. These connections should be provided at the installation site.
v Analog phone line – A dedicated analog phone line with long distance capabilities
2
IBM TotalStorage DS4000 Alert Manager Appliance: Planning and Installation Guide
Indicate whether the appliance is normally connected to a phone line and
whether IBM Service should contact your staff before connecting to the
appliance.
Note: If the appliance is not connected to a phone line, then monitoring of
problems cannot be performed. In this case, the appliance is used
only for remote access to a DS4000 storage server when a problem
has been reported to IBM Service.
Indicate whether heartbeat checks are permitted. During a heartbeat check,
IBM Service dials into the appliance to verify that the phone line and
appliance are operational. There is no access to any DS4000 storage
server during a heartbeat check. You may choose to permit or not permit
calls to the appliance to perform these checks.
The storage server names given should match precisely the storage
Serial
number
23A3040
23B0211
23A3110
is required. Document the phone number assigned to this line.
Subsystem
New or
name
existing
KeyBiscayne
New
KeyLargo
New
KeyWest
New
Length of
cables
Number of
needed
controllers
16
2
16
1
50
2

Advertisement

Table of Contents
loading

Table of Contents