Baier 50VA Instruction Manual

24v motor control box

Advertisement

Quick Links

INSTRUCTIONMANUAL
24V 50VA Motor control box
Product group:
Version:
Language:
Orig. Language:
Document:
Sliding doors, - windows, - shutters
1.0
english
german (deutsch)
------
Baier GmbH
Reiersbacher Strasse 28
D-77871 Renchen-Ulm
Tel. +49 (0) 78 43 / 94 76 - 0
Fax +49 (0) 78 43 / 94 76 - 33
info@baier-gmbh.de
www.baier-gmbh.de

Advertisement

Table of Contents
loading

Summary of Contents for Baier 50VA

  • Page 1 INSTRUCTIONMANUAL 24V 50VA Motor control box Product group: Sliding doors, - windows, - shutters Baier GmbH Reiersbacher Strasse 28 Version: D-77871 Renchen-Ulm Language: english Tel. +49 (0) 78 43 / 94 76 - 0 Fax +49 (0) 78 43 / 94 76 - 33 Orig.
  • Page 2 +49 (0) 78 43 / 94 76 - 0 +49 (0) 78 43 / 94 76 - 33 info@baier-gmbh.de www.baier-gmbh.de Document information Document type: Instruction Manual Title: 24V 50VA Motor control box Product group: Sliding doors, sliding windows, sliding shutters Version: Language: english Orig. language: german (deutsch)
  • Page 3: Table Of Contents

    Configuration ..................14 6.1.1 Automatic closing delay time 6.1.2 Tolerance of power operated shutdown 6.1.3 Configuration Switch Steps during initial operation............. 17 Behavior after a power cut ..............18 24V 50VA Motor control box - Instruction Manual 3/20 Version 1.0...
  • Page 4: About This Document

    Additional documents like guidelines, standards and laws for products of this kind, have to be considered. Hint The fabricator has an increased duty to advice the customer. The relevant guidelines, standards and laws have to be considered. 4/20 Instruction Manual 24V 50VA Motor control box - Version 1.0...
  • Page 5: Used Symbols

    Lists 1. symbolizes a list or instruction in specific order  symbolizes an action Instructions  symbolizes a reference  symbolizes the result of the action 24V 50VA Motor control box - Instruction Manual 5/20 Version 1.0...
  • Page 6: Safety

    Read the instruction manual before doing any work on the motor control box. 2.1.1 Environmental conditions The 24V 50VA motor control box is designed for use in dry interior. 2.2 Proper use This product is a motor control device for 24V DC motors of the manufacturer. It is powered by an internal 24V power supply.
  • Page 7: Functional Description

    3 Functional description 3.1 General description Hint This document describes the functionality of the 24V 50VA motor control box. Instruction manuals for the installation of the mechanical part of the sliding door, window or shutter are available in separate documents.
  • Page 8: Modes Of Operation

    24 V DC output and optionally two potential free relay outputs. For configuration of special functions or application examples, please contact the manufacturer. 8/20 Instruction Manual 24V 50VA Motor control box - Version 1.0...
  • Page 9: Cabling

    50 m (160 ft): 2 x 0,25 mm² (22 AWG) Appliance, configurable IOs Dependent on requirements up to 50 m (160 ft): Table 1 – Cable requirements 24V 50VA Motor control box - Instruction Manual 9/20 Version 1.0...
  • Page 10: Mounting And Electrical Connection

    A 10 A automatic circuit breaker must be installed in the power path of the motor control box. 5.2.2 Power line connection diagram 10 A circuit breaker (on site) All-pole mains switch (on site) Motor control box 10/20 Instruction Manual 24V 50VA Motor control box - Version 1.0...
  • Page 11: Electrical Connection

     Connect potential free on-site actuator (terminals 7, 9, 10).  Connect appliances dependent on requirements.  Motor control box connected successfully. Motor control box terminals Motor cable color coding 24V 50VA Motor control box - Instruction Manual 11/20 Version 1.0...
  • Page 12: Exemplary Connection Of On-Site Actuators

    Output NO (potential free) Ground Open Ground Power supply input +24V DC When a motion detector is used, the motor control device must be set to automatic operation mode. 12/20 Instruction Manual 24V 50VA Motor control box - Version 1.0...
  • Page 13: Initial Operation

    Potentiometer P1 and P2 Configuration switch LED „Configuration“ LED „Close“ Reset key LED „Open“ Service key „Close“ (ZU) Service key „Open“ (AUF) LED „24V OK“ Figure 2 Service elements 24V 50VA Motor control box - Instruction Manual 13/20 Version 1.0...
  • Page 14: Configuration

     Door stays open for a longer time. Reduce automatic  Turn potentiometer 1 (P1) counterclockwise closing delay time  Door stays open for a shorter time. 14/20 Instruction Manual 24V 50VA Motor control box - Version 1.0...
  • Page 15: Tolerance Of Power Operated Shutdown

    Decrease tolerance  Turn potentiometer 2 (P2) counterclockwise  Drive switches off sooner Hint After a maximum operating time of 5 minutes, the drive switches off in any case. 24V 50VA Motor control box - Instruction Manual 15/20 Version 1.0...
  • Page 16: Configuration Switch

    When enabled, the drive will operate generally in low speed mode. Closing and opening speed are reduced. Switch 7: The combination of switches 7 and 8 sets the maximum speed of the drive. (Refer to table 2). 16/20 Instruction Manual 24V 50VA Motor control box - Version 1.0...
  • Page 17: Steps During Initial Operation

     For electrical connection refer to chapter 5.3.  For configuration refer to chapter 6.1.  Repeat initial operation, if necessary.  Initial operation is completed, when function is correct. 24V 50VA Motor control box - Instruction Manual 17/20 Version 1.0...
  • Page 18: Behavior After A Power Cut

     Motor shuts down and red LED stops blinking.  Normal operation is restored. Hint After a power cut, no further initial operation is necessary. The operation parameters are saved permanently during initial operation. 18/20 Instruction Manual 24V 50VA Motor control box - Version 1.0...
  • Page 19 . b a i e r - g m b h . d e Initial operation 24V 50VA Motor control box - Instruction Manual 19/20 Version 1.0...
  • Page 20 Bei uns erhalten Sie bewährte Qualität: Baier GmbH Reiersbacher Strasse 28 D-77871 Renchen-Ulm Tel. +49 (0) 78 43 / 94 76 - 0 Fax +49 (0) 78 43 / 94 76 - 33 info@baier-gmbh.de www.baier-gmbh.de...

Table of Contents