Download Print this page

HWH SPACEMAKER Operator's Manual

Hydraulic room extension systems
Hide thumbs Also See for SPACEMAKER:

Advertisement

Quick Links

OPERATOR'S MANUAL
HWH HYDRAULIC SPACEMAKER
ROOM EXTENSION SYSTEMS
Single / Multiple Room Extensions / Generator Slide
UNDERSTAND OPERATOR'S MANUAL BEFORE
UNDERSTAND OPERATOR'S MANUAL BEFORE
USING. KEEP PEOPLE AND OBSTRUCTIONS
USING. KEEP PEOPLE AND OBSTRUCTIONS
Ph: 800/321-3494 (or) 563/724-3396 | Fax: 563/724-3408
AP40086
H H
W
CORPORATION
R
FEATURING:
H
H
CORPORATION
CORPORATION
HYDRAULIC ROOM EXTENSION
HYDRAULIC ROOM EXTENSION
OFF
OFF
ON
ON
CAUTION!
CAUTION!
CLEAR OF ROOM WHEN OPERATING.
CLEAR OF ROOM WHEN OPERATING.
HWH CORPORATION
(On I-80, Exit 267 South)
2096 Moscow Road | Moscow, Iowa 52760
www.hwh.com
R
W
W
H
H
R
R
EXTEND
EXTEND
RETRACT
RETRACT
R R
ML40087/MP04.0281
05FEB07

Advertisement

loading

Summary of Contents for HWH SPACEMAKER

  • Page 1 CORPORATION OPERATOR’S MANUAL HWH HYDRAULIC SPACEMAKER ROOM EXTENSION SYSTEMS FEATURING: Single / Multiple Room Extensions / Generator Slide CORPORATION CORPORATION HYDRAULIC ROOM EXTENSION HYDRAULIC ROOM EXTENSION EXTEND EXTEND CAUTION! CAUTION! UNDERSTAND OPERATOR’S MANUAL BEFORE UNDERSTAND OPERATOR’S MANUAL BEFORE USING. KEEP PEOPLE AND OBSTRUCTIONS USING.
  • Page 2: How To Obtain Warranty Service

    HWH CORPORATION personnel will contact you to the problem quickly. If the dealer has difficulty solving determine whether or not your claim is valid. If it is, HWH the problem, he should immediately contact the Customer CORPORATION will authorize repair or replacement of the Service Department, at HWH CORPORATION.
  • Page 3: Control Identification

    CONTROL IDENTIFICATION ROOM OPERATOR’S PANEL CORPORATION HYDRAULIC ROOM EXTENSION EXTEND ROOM CONTROL KEY SWITCH SWITCH CAUTION! UNDERSTAND OPERATOR’S MANUAL BEFORE USING. KEEP PEOPLE AND OBSTRUCTIONS RETRACT CLEAR OF ROOM WHEN OPERATING. CONTROL FUNCTIONS KEY SWITCH: The KEY SWITCH controls power to the ROOM ROOM CONTROL SWITCH: The ROOM CONTROL SWITCH CONTROL SWITCH.
  • Page 4: Operating Procedures

    NOTE: If the vehicle is equipped with an HWH 225 series joystick leveling system, the on light on the leveling system panel MAY have to be on to operate a room extension.
  • Page 5 DO NOT reverse direction of the room, contact 3. Unlock all room-locking devices to include travel HWH Customer Service for assistance 1-800-321-3494. clamps/locks supplied by manufacturers other than HWH. NOTE: Releasing the ROOM CONTROL SWITCH will NOTE: If the MANUAL RETRACT WINCH is attached to halt the operation of the room.
  • Page 6 DO NOT reverse direction of the room, contact 1. The park brake must be set, if applicable. HWH Customer Service for assistance 1-800-321-3494. The room will not operate if the park brake is not set. NOTE: Releasing the ROOM CONTROL SWITCH will 2.
  • Page 7 When the slide is fully retracted, release the GENERATOR SLIDE CONTROL SWITCH. IN THE EVENT OF FAILURE OF THE GENERATOR SLIDE TO RETRACT, REFER TO THE MANAUAL ROOM AND GENERATOR SLIDE RETRACT PROCEDURES OR CONTACT HWH CORPORATION CUSTOMER SERVICE AT 1-319-724-3396 OR 1-800-321-3494 FOR ASSISTANCE. MP34.6100 07FEB07...
  • Page 8 Follow steps 2 and 3 and try pushing the room in. it to the room according to the vehicle manufacturer’s Contact the vehicle manufacturer or HWH Customer instructions. To extend the WINCH STRAP firmly grasp Service at 1-800-321-3494 or 563-724-3396 for assistance.
  • Page 9 BREATHER IMPORTANT: If at any stage something is not CAP-DIP understood or if the room begins to bind DO NOT force STICK the room, contact HWH Customer Service for assistance 1-800-321-3494. HYDRAULIC PUMP/MANIFOLD LEVELING SYSTEM MANIFOLD NOT SHOWN Thumb Screw...
  • Page 10 IMPORTANT: If at any stage something is not CAP-DIP understood or if the room begins to bind DO NOT force STICK the room, contact HWH Customer Service for assistance 1-800-321-3494. HYDRAULIC PUMP/MANIFOLD LEVELING SYSTEM MANIFOLD NOT SHOWN Manual Retraction Bolt Thumb Screw MP34.9552...
  • Page 11 VALVE IMPORTANT: If at any stage something is not RELEASE understood or if the room begins to bind DO NOT force the room, contact HWH Customer Service for assistance 1-800-321-3494. BREATHER CAP-DIP NOTE: Leave the solenoid valves open and the...
  • Page 12 VALVE IMPORTANT: If at any stage something is not RELEASE understood or if the room begins to bind DO NOT force the room, contact HWH Customer Service for assistance 1-800-321-3494. BREATHER CAP-DIP NOTE: Leave the solenoid valves open and the...
  • Page 13 RELEASE VALVE IMPORTANT: If at any stage something is not RELEASE understood or if the room begins to bind DO NOT force the room, contact HWH Customer Service for assistance 1-800-321-3494. BREATHER CAP-DIP STICK NOTE: Leave the solenoid valves open and the threaded rods in place until the room has been serviced.
  • Page 14 4. Follow MANUAL ROOM RETRACT PROCEDURES. VALVE (ML36687/MP35.956D) RELEASE IMPORTANT: If at any stage something is not understood or if the room begins to bind DO NOT force the room, contact HWH Customer Service for assistance BREATHER CAP-DIP 1-800-321-3494. STICK HYDRAULIC PUMP/MANIFOLD...
  • Page 15 IMPORTANT: If at any stage something is not manual room retraction procedures. understood or if the room begins to bind DO NOT force the room, contact HWH Customer Service for assistance 1. Start both threaded rods until resistance is met, one for 1-800-321-3494.
  • Page 16 BREATHER CAP - DIPSTICK - 1/4" NUT DRIVER 1 1/2" DIAMETER VALVE RELEASE SOLENOID VALVE NOTE: DO NOT turn the valve release nut more than 4 and 1/2 (four and one half) turns counter clockwise. Damage to the valve may result. VALVE RELEASE PLASTIC PLUG 2 1/4"...