NCR SelfServ™ 84 Walk‐Up ATM Site Preparation
Site Requirements
TEMPERATURE AND HUMIDITY
Continuous operating at or near the range limits, or in a location where the
temperature and humidity change beyond the specification, should be avoided.
If installing though an exterior wall, the site must meet the requirements of
both the Interior and Exterior environments.
Note: For exterior through the wall ATMs the humidity inside the building is
restricted to a maximum of 30% at an outside temperature of ‐35°C
(‐31°F), with a linear relationship between temperature and humidity to
a maximum humidity at 0°C (32°F).
Normal Operating Range (Interior Environment)
Temperature: 0°C to 40°C (32°F to 104°F)
Relative Humidity: 20% to 80%
Dew Point Temperature Restriction: 26°C (79°F) maximum
Normal Operating Range (Exterior Environment)
Temperature:
without Passbook Printer: ‐35°C to 50°C (‐31°F to 122°F)
with Passbook Printer: 0°C to 40°C (32°F to 104°F)
Relative Humidity:
without Passbook Printer: 10% to 100%
with Passbook Printer fitted: 10% to 80%
Dew Point Temperature Restriction: 26°C (79°F) maximum
Storage Range (Up To Three Months)
Temperature: ‐10°C to 50°C (14°F to 122°F)
Relative Humidity: 10% to 90%
Transit Range (Up To One Week)
Temperature: ‐40°C to 60°C (‐40°F to 140°F)
Relative Humidity: 5% to 95%
Extreme Power On Range (Up To One Hour)
Temperature: 0°C to 45°C (32°F to 113°F)
Relative Humidity: 10% to 95%
NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2017, 2018 by NCR Corporation, Atlanta, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved
BAROMETRIC PRESSURE
Operating/Transit Limits: 105 kPa (15.2 lbf/in
Equivalent Altitude: Up to a maximum of 3000 m (9842.52 ft)
2
2
.) to 70 kPa (10.2 lbf/in
.)
5 ‐ 2
B006‐7519‐G000