  • Page 1 NCR SelfServ  34 Drive‐Up ATM Site Preparation ™   B006‐7206‐E000...
  • Page 2  NCR SelfServ™ 34 Drive‐Up ATM Site Preparation The product described in this document is a licensed product of NCR  Corporation.  NCR and NCR SelfServ are trademarks of NCR Corporation. Other product  names mentioned in this publication may be trademarks or registered  trademarks of their respective companies and are hereby acknowledged. Where creation of derivative works, modifications or copies of this NCR  copyrighted documentation is permitted under the terms and conditions of an  agreement you have with NCR, NCR's copyright notice must be included. It is the policy of NCR Corporation (NCR) to improve products as new  technology, components, software, and firmware become available. NCR,  therefore, reserves the right to change specifications without prior notice. All features, functions, and operations described herein may not be marketed  by NCR in all parts of the world. In some instances, photographs are of  equipment prototypes. Therefore, before using this document, consult with  your NCR representative or NCR office for information that is applicable and  current. NCR Proprietary Information ‐ not to be disclosed or reproduced without  written consent. © 2013, 2014, 2015 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.  All Rights Reserved   B006‐7206‐E000...
  • Page 3: Table Of Contents

    With Pressurisation ............... 10 ‐ 2 Power Cable..................7 ‐ 3 Emission Standards................3 ‐ 1 Cable Entry ..................10 ‐ 2 Additional Requirements for 220V ‐ 240V Units ......3 ‐ 1 Accessibility ..................3 ‐ 1 Security Bolts..................10 ‐ 2 Decals NCR Optimum Height ..............3 ‐ 1 Bolt Holes ................... 10 ‐ 2 Card Orientation Window ..............8 ‐ 1 Lowered Heights................3 ‐ 1 Facia Items ..................10 ‐ 3 Advert Window ..................8 ‐ 1 Heights and Depths ............... 10 ‐ 3 Advert Window ................8 ‐ 1 Distance for Voice Guidance ............10 ‐ 3 Product Overview...
  • Page 4  NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Contents Facia Items..................11 ‐ 3 Heights and Depths ...............11 ‐ 3 Distance for Voice Guidance ............11 ‐ 3 Servicing Areas ‐ Optimum ..............11 ‐ 4 Servicing Areas ‐ Minimum..............11 ‐ 4 Clearances ‐ Corridor ................11 ‐ 5 Clearances ‐ Exterior Wall..............11 ‐ 5 Standard Collar ................11 ‐ 5 Advert Collar..................11 ‐ 5 Internal Space Constraint for Third‐Party Camera ......11 ‐ 5 Variant Details ‐ UL, Standard Sleeve Package Dimensions ................12 ‐ 1 ATM Dimensions.................12 ‐ 1 Collar Dimensions ................12 ‐ 1 Standard ..................12 ‐ 1 Advert ....................12 ‐ 1 Hole in the Wall ..................12 ‐ 1 Weight and Floor Loading..............12 ‐ 1 Security Bolts ..................12 ‐ 2 Bolt Holes....................12 ‐ 2 Cable Entry..................12 ‐ 2 Facia Items..................12 ‐ 3 Heights and Depths ...............12 ‐ 3 Distance for Voice Guidance ............12 ‐ 3 Servicing Areas ‐ Optimum ..............12 ‐ 4...
  • Page 5: Audience

    Date Revision Pages Reason for Change site prior to the arrival of the ATM. screens. Each section has been structured to fit the maximum amount of  March 2013 All New manual to cover SelfServ 34 Drive-up variant. information on the minimum number of pages yet still be readable when  Includes all requirements from NCR SelfServ™ 32, 34, printed on A3 size paper. Printing on smaller paper sizes may reduce readability  and 38 Site Preparation Requirements, B006-6670 and but will make handling easier. updated security bolts specification.
  • Page 6: Customer Responsibilities

    Provide storage or service areas as required.  and equipment other than those specified by NCR. Such  to be comprehensive, and in no way modifies, alters, or limits the responsibility  Make sure the environmental requirements of the system/unit are met.  unauthorized modifications, substitutions, or attachments may  of the customer for all aspects of adequate site preparation. Provide floor coverings and environmental systems that limit or control   void the user’s authority to operate the equipment. The correction  static electricity build‐up and discharge. NCR staff will be available to answer questions relating to the contents of this  of interference caused by such unauthorized modifications,  document but, except where: Install the product at a height which meets the accessibility regulations  substitutions, or attachments will be the responsibility of the user.  of the relevant country. a. the customer has been notified that a full or partial consultancy service  is available and/or that NCR will be willing to undertake a preliminary or  final site survey and b. the customer shall have entered into a formal contract with NCR for  provision of the same no comment, suggestion or advice offered or not offered about preparation of  the site nor any inspection of the site whether before or after preparation is to  be taken as approval of the location of the site and equipment or of its  preparation and NCR will not be liable in respect of any comment, suggestion or  advice given by its staff or in respect of any failure to give advice. Finally, only the customer can know the full extent of damage which   may be caused to his business by reason of failure of the equipment  which is to be installed. For this reason it is the customer’s responsibility  to ascertain the extent of any such possible damage to his existing or  planned business, and to effect, full insurance in respect of it. NCR Proprietary Information ‐ not to be disclosed or reproduced without written consent. © 2013, 2014, 2015 by NCR Corporation, Duluth, Georgia, U.S.A. http://www.ncr.com.All Rights Reserved B006‐7206‐E000...
  • Page 7: Standards Compliance

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Standards Compliance 3 ‐ 1 RADIO FREQUENCY INTERFERENCE ELECTROMAGNETIC COMPATIBILITY (EMC) ACCESSIBILITY FCC Radio Frequency Interference Statement Immunity Standards NCR Optimum Height This equipment has been tested and found to comply with the limits for a Class  The ATM complies with the following requirements for radiated and conducted  This height assures the best display viewability for able‐bodied people. It does  A digital device, pursuant to Part 15 of the Federal Communications  immunity:  NOT comply with the lowered height regulations listed in the next section. Commission (FCC) Rules. These limits are designed to provide reasonable  EN 55024  protection against harmful interference when the equipment is operated in a  Lowered Heights As per the requirements of EN55024, the ATM complies with the requirements  commercial environment. This equipment generates, uses, and can radiate  of the following normative Immunity Standard:  radio frequency energy and, if not installed and used in accordance with the  The lowered installation heights are designed to meet the regulations below  instruction manual, may cause harmful interference to radio communications.  and therefore accommodate use by both able‐bodied and disabled people. EN 61000‐4‐2 Electrostatic Discharge  Operation of this equipment in a residential area is likely to cause harmful  EN 61000‐4‐3 Radiated RF  Lowered heights are specified for the following regulations: interference in which case you, the customer, will be required to correct the  EN 61000‐4‐4 Electrical Fast Transient/Burst  interference at your own expense. (UK) Access to ATMs: UK Design Guidelines 2002, Centre for Accessible   EN 61000‐4‐5 Surge ...
  • Page 8: Product Overview

     location.  68 dB(A) when operating (see note).  However, the following configurations will affect the sound levels as shown in  ™ NCR SelfServ XX the table below: Class: XXXX Model: XXXX NCR Global Solutions Ltd. XX - XXXXXXXX Serial: Tracer: XX - XX Configuration Acoustic sound power when operating Vãc: XXX - XXXv Hz: 50/60 A: X.X...
  • Page 9: Site Requirements

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Site Requirements 5 ‐ 1 POSITIONING THE ATM WALL Collar Tolerance The collar has a tolerance of +/‐ 4 mm (0.2 in. (+/‐ 0.5°)) at the top and bottom,  The ATM may be installed through any suitable exterior wall or vestibule  A 25 mm (1.0 in.) wide smooth surface is required around the edge of the wall  with 0 mm (0.0 in. (0°)) at its centre.  location. opening to enable a good weather seal. The collar cannot accommodate large dips or depressions in the wall. Make  The ATM must also be positioned away from heat sources or any air  sure the wall is smooth and even. conditioning equipment. Wall Cavity Bright lights and windows behind the user may degrade camera performance.  Any cavity in the wall must be sealed to provide a flush surface that does not  Position the ATM away from direct sunlight. +/- 4 mm extend into the wall opening. Leave the gap between the ATM sleeve and the  (0.16 in.) wall opening clear to allow air at room temperature to circulate. Allow sufficient room for installation and servicing requirements. Seal any cavity 0.0 mm Do not block air gaps (0.0 in.) FLOOR The ATM must be installed on a level, even, concrete or other noncombustible ...
  • Page 10: Temperature And Humidity

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Site Requirements 5 ‐ 2 TEMPERATURE AND HUMIDITY  BAROMETRIC PRESSURE  Continuous operating at or near the range limits, or in a location where the  Operating/Transit Limits: 105 kPa (15.2 lb.F/in.) to 70 kPa (10.2 lb.F/in.)   temperature and humidity change beyond the specification, should be avoided. Equivalent Altitude: Up to a maximum of 3000 m (9842.52 ft)  If installing though an exterior wall, the site must meet the requirements of  both the Interior and Exterior environments. Note: For exterior through the wall ATMs the humidity inside the building is  restricted to a maximum of 30% (20% if Tilting Display fitted) at an  outside temperature of ‐35°C(‐31°F), with a linear relationship between  temperature and humidity to a maximum humidity at 0°C (32°F). Normal Operating Range (Interior Environment) Temperature:  without Severe Environment: 10 C to 40 C (50 F to 104  with Severe Environment fitted: 0 C to 40 C (32 F to 104  Relative Humidity: 20% to 80%  Dew Point Temperature Restriction: 26 C (79 F) maximum  If a pressurisation unit is fitted then minimum operating temperature is  C (50 F) even with severe environment fitted.
  • Page 11: Power Requirements

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Power Requirements 6 ‐ 1 AC POWER REQUIREMENTS GROUNDING TRANSIENT PROTECTION The maximum current requirements are: The ATM operates from a single phase, 3 wire supply: live, neutral and ground. In the process of power distribution, transient electrical energy (including, but  not limited to, lightning strikes, intermittent short circuits, and switching  10A at 120V The ATM power requirements will normally permit it to operate within existing   transients) can be introduced on to power lines. Such transient energy can be  wiring configurations and from existing mains outlets provided that: 6.3A at 230V.  very damaging to electronic hardware and can also cause data corruption.  the branch circuit of the distribution panel supporting the ATM is not  Under these circumstances, NCR recommends the use of AC power transient  The maximum inrush current is 100A.  also used to support equipment with heavy inductive loads such as air  suppressors and data (communication) line transient suppressors. Such  NCR does not recommend running an ATM with deposit devices without an  conditioners or AC motors. protective devices are intended to guard against power and data line transients  Uninterruptible Power Supply (UPS). Without a UPS, there is the potential for  that can result in hardware damage and various system or program errors. other branch circuits on the same distribution panel do not support   customer’s cash to be retained in the device if there is a power failure. such equipment. Improvement of any deficiencies in power quality is a customer responsibility.  the installation meets or exceeds the regulatory and local guidelines   Malfunction and/or component failure as a result of power quality problems  with regard to electrical safety and all conductor sizing. INPUT VOLTAGE SETTING are/is not covered by NCR Corporation Maintenance Agreement. NCR accepts ...
  • Page 12: Cable Requirements

    When producing cables allow for 2.2 m (7.22 ft) of cable within the ATM. DATA LINE TRANSIENT PROTECTION 1. Connector, 9 way (NCR part no. 006-0010488). 1. Connector, 25 Way (NCR part no. 006-0005897) 2. Terminal wire, female (NCR part no. 009-0002640). 2. Terminal, wire, male (NCR part no. 009-0002642) Voltage transients, line noise, surges, sags, impulses, and spikes may be  3. Cable, shielded multiconductor (NCR part no. 007-8907033).
  • Page 13: Alarm Interface Cables

    12V +/‐ 2V dc  200mA maximum  1. Connector, 25 Way (NCR part no. 006-0005896) 1. Connector, 25 Way (NCR part no. 006-0005896) Ripple, 5% maximum. 2. Terminal, wire, female (NCR part no. 009-0002640) 2. Terminal, wire, female (NCR part no. 009-0002640) ...
  • Page 14: Remote Status Monitor

    220‐240V ATMs are supplied with an unterminated power cable. Information  1, 2 about suitable power connectors is supplied with the accessories. The power cable supplied is 3 m (9.84 ft) in length. If it is necessary to increase  this length to meet site requirements, then the extension must satisfy local or  country regulations.  1. Connector, 2 way Mate-N-Lock (NCR part no. 007-9814285). WARNING This equipment must be earthed. 2. Terminal wire, male (NCR part no. 007-2009663). 3. Cable, multiconductor (NCR part no. 006-5800006). 4. Connector (determined by remote device). Remove a 20 mm (0.8 in.) section of the outer sleeve, 125 mm (4.9 in.) from the ...
  • Page 15: Decals

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Decals 8 ‐ 1 CARD ORIENTATION WINDOW ENTRY/EXIT DECALS DECAL PLACEMENT An industry standard credit card can be placed behind the card orientation  Entry/Exit decals should be a maximum of 0.5 mm (0.02 in.) thick. NCR  NCR recommends placing entry/exit decals above or below the entry/exit slots,  window. The card or decal should be a maximum of 0.75 mm (0.0295 in.) thick. recommends they be made from textured polycarbonate with 3M 467 High  determined by the space available near the slot. Performance MP adhesive. Cash Blank Window decal and Card Orientation Window decal/card are placed  Decals should provide good contrast, at least 70%, between foreground (text/ on the inside of the window. icon) and background.  Advert window decals can be placed on either the front or the inside of the  A sans serif typeface should be used (Tiresias is recommended). The text size  window. 15 mm should be at least 14 point, and larger where possible. Where tactile decals are  (0.59 in.) Coin required they should be designed in line with specific country requirements. Suggested icon designs and wording are shown below: 86 mm 70 mm 48 mm (3.39 in.) (2.76 in.) (1.89 in.)
  • Page 16: Variant Details - Cen, Short Sleeve

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ CEN, Short Sleeve 9 ‐ 1 PACKAGE DIMENSIONS COLLAR DIMENSIONS With Pressurisation 773 mm (30.43 in.) 977 mm Standard 1435 mm (38.46 in.) 47 mm (56.50 in.) (1.85 in.) 63 mm 800 mm 725 mm 1088 mm (2.48 in.) (31.50 in.) (28.54 in.) (42.83 in.) 65 mm...
  • Page 17: Weights And Floor Loading

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ CEN, Short Sleeve 9 ‐ 2 WEIGHTS AND FLOOR LOADING CABLE ENTRY BOLT HOLES The ATM should be bolted to the floor or plinth, through all the holes marked  770 mm ‘A’, using four bolts with anchor washers. (30.31 in.) Without Pressurisation The ‘B’ hole enables an alarm to be fitted (CEN III security enclosures only). Standard Security Enclosures 770 mm CEN grade L CEN grade III 403 mm 65 mm (30.3 in.) (15.87 in.) 888 kg 985 kg (2.66 in.) Maximum weight 170 mm 500 mm (1958 lb.)
  • Page 18: Facia Items

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ CEN, Short Sleeve 9 ‐ 3 FACIA ITEMS Heights and Depths Distance for Voice Guidance Height Depth Facia Item from base from front of ATM of collar Distance from Facia Item 1120 mm 36 mm No. 5 Key Statement Exit (44.09 in.) (1.42 in.) 7 6 5 1124 mm...
  • Page 19: Servicing Areas - Optimum

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ CEN, Short Sleeve 9 ‐ 4 SERVICING AREAS ‐ OPTIMUM SERVICING AREAS ‐ MINIMUM The optimum servicing area provides the best access to the ATM for all  This is the minimum area required for operating and servicing the ATM. servicing and operation tasks. Wherever possible the ATM should be installed within the optimum servicing  Wherever possible the ATM should be installed within the optimum servicing  area. Installing the ATM in the minimum servicing area may increase the  area. servicing and/or upgrading time.  If the optimum area is not available then refer to Servicing Areas ‐ Minimum.  If the minimum area is not available then consult your local service  However note that installing the ATM in the minimum servicing area may  representative. Every site is different and you may still be able to install the  increase the servicing and/or upgrading time over a ATM installed using the  ATM but with further increases to servicing and/or upgrading time. optimum area.  If you install in the minimum area then note that doors can open, and devices  Always leave as much space as possible around the ATM to facilitate safe  rack out, beyond the area shown. Always leave as much space as possible  operation and servicing. around the ATM to facilitate safe operation and servicing. 1780 mm Minimum clearance (70.08 in.) Additional clearances required for: 525 mm 25 mm (20.67 in.) (0.98 in.)
  • Page 20: Clearances - Corridor

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ CEN, Short Sleeve 9 ‐ 5 CLEARANCES ‐ CORRIDOR CLEARANCES ‐ EXTERIOR WALL CLEARANCE ‐ PRESSURISATION FAN The dimensions shown assume the ATM is being moved using equipment that  The illustration below shows the minimum height clearance required for the  does not extend beyond the ATM or packaging. installation, removal, and replacement of the pressurisation fan. Standard Collar A surrounding clearance of 6 mm (0.24 in.) has been allowed in the dimensions. 350 mm 493 mm 10 mm (13.8 in.) (19.4 in.) (0.39 in.) 45 mm (1.77 in.) 30 mm 30 mm (1.18 in.) (1.18 in.) Advert Collar Packaged ATM Packaged ATM...
  • Page 21: Variant Details - Cen, Standard Sleeve

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ CEN, Standard Sleeve 10 ‐ 1 PACKAGE DIMENSIONS COLLAR DIMENSIONS With Pressurisation 773 mm (30.4 in.) 977 mm Standard 1435 mm (38.46 in.) 47 mm (56.50 in.) (1.85 in.) 63 mm 800 mm 725 mm (2.48 in.) (31.5 in.) 1202 mm (28.54 in.) 65 mm 605 mm (47.3 in.)
  • Page 22: Weights And Floor Loading

    NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ CEN, Standard Sleeve 10 ‐ 2 WEIGHTS AND FLOOR LOADING CABLE ENTRY BOLT HOLES The ATM should be bolted to the floor or plinth, through all the holes marked  770 mm ‘A’, using four bolts with anchor washers. (30.31 in.) Without Pressurisation The ‘B’ hole enables an alarm to be fitted (CEN III security enclosures only). Standard Security Enclosures 770 mm CEN grade L CEN grade III 403 mm (30.31 in.) 65 mm (15.87 in.) 888 kg 985 kg (2.66 in.) Maximum weight 170 mm 500 mm (1958 lb.)
  • Page 23: Facia Items

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ CEN, Standard Sleeve 10 ‐ 3 FACIA ITEMS Heights and Depths Distance for Voice Guidance Height Depth Facia Item from base from front of ATM of collar Distance from Facia Item 1120 mm 36 mm No. 5 Key Statement Exit (44.09 in.) (1.42 in.) 7 6 5 1124 mm...
  • Page 24: Servicing Areas - Optimum

    NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ CEN, Standard Sleeve 10 ‐ 4 SERVICING AREAS ‐ OPTIMUM SERVICING AREAS ‐ MINIMUM The optimum servicing area provides the best access to the ATM for all  This is the minimum area required for operating and servicing the ATM. servicing and operation tasks. Wherever possible the ATM should be installed within the optimum servicing  Wherever possible the ATM should be installed within the optimum servicing  area. Installing the ATM in the minimum servicing area may increase the  area. servicing and/or upgrading time.  If the optimum area is not available then refer to Servicing Areas ‐ Minimum.  If the minimum area is not available then consult your local service  However note that installing the ATM in the minimum servicing area may  representative. Every site is different and you may still be able to install the  increase the servicing and/or upgrading time over a ATM installed using the  ATM but with further increases to servicing and/or upgrading time. optimum area.  If you install in the minimum area then note that doors can open, and devices  Always leave as much space as possible around the ATM to facilitate safe  rack out, beyond the area shown. Always leave as much space as possible  operation and servicing. around the ATM to facilitate safe operation and servicing. Minimum clearance 1780 mm Additional clearances required for: (70.08 in.) 525 mm 25 mm Cash Acceptor/Recycler or Scalable Deposit Module (LH side) (20.67 in.)
  • Page 25: Clearances - Corridor

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ CEN, Standard Sleeve 10 ‐ 5 CLEARANCES ‐ CORRIDOR CLEARANCES ‐ EXTERIOR WALL CLEARANCE ‐ PRESSURISATION FAN The dimensions shown assume the ATM is being moved using equipment that  The illustration below shows the minimum height clearance required for the  does not extend beyond the ATM or packaging. installation, removal, and replacement of the pressurisation fan. Standard Collar A surrounding clearance of 6 mm (0.24 in.) has been allowed in the dimensions. 350 mm 493 mm 10 mm (13.8 in.) (19.4 in.) (0.39 in.) 45 mm (1.77 in.) 30 mm 30 mm (1.18 in.) (1.18 in.) Advert Collar Packaged ATM Packaged ATM...
  • Page 26: Variant Details - Ul, Short Sleeve

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ UL, Short Sleeve 11 ‐ 1 PACKAGE DIMENSIONS COLLAR DIMENSIONS HOLE IN THE WALL It is the responsibility of the owning institution to ensure that the heights from  the sidewalk level to the facia items comply with any local regulations. Where  977 mm Standard 1435 mm (38.46 in.) no such regulations exist, the ATM can be installed at the NCR optimum height. 47 mm (56.50 in.) (1.85 in.) 63 mm For correct installation height you must consider the difference in height  725 mm (2.48 in.) between the sidewalk and the interior floor. If there is no difference then the  (28.54 in.) 38 mm plinth must have the height specified in the illustration below. (1.50 in.) 725 mm 1836 mm 625 mm (28.54 in.)
  • Page 27: Security Bolts

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ UL, Short Sleeve 11 ‐ 2 SECURITY BOLTS BOLT HOLES CABLE ENTRY Bolts and anchors must be supplied by the owning organisation. The ATM should be bolted to the floor or plinth, through all the holes marked  770 mm ‘A’, using four bolts with anchor washers. (30.31 in.) To meet security standards the ATM must be bolted to the floor, through all of  the bolt holes, using bolts with anchor washers as specified below. Bolts and  anchor washers are to be supplied by the owning organisation. 770 mm 165 mm (30.31 in.) (6.50 in.) Make sure that the floor or plinth is capable of withstanding the loading  408 mm 36 mm imposed by the anchor points for these bolts. Security Enclosure Ø 25 mm (16.06 in.) 30 mm (1.42 in.) (0.98 in.)
  • Page 28: Facia Items

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ UL, Short Sleeve 11 ‐ 3 FACIA ITEMS Heights and Depths Distance for Voice Guidance Height Depth Facia Item from base from front of ATM of collar Distance from Facia Item 1111 mm 36 mm No. 5 Key Statement Exit (43.75 in.) (1.42 in.) 7 6 5 1115 mm...
  • Page 29: Servicing Areas - Optimum

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ UL, Short Sleeve 11 ‐ 4 SERVICING AREAS ‐ OPTIMUM SERVICING AREAS ‐ MINIMUM  This is the minimum area required for operating and servicing the ATM. The optimum servicing area provides the best access to the ATM for all  servicing and operation tasks. Wherever possible the ATM should be installed within the optimum servicing  area. Installing the ATM in the minimum servicing area may increase the  Wherever possible the ATM should be installed within the optimum servicing  servicing and/or upgrading time.  area. If the minimum area is not available then consult your local service  If the optimum area is not available then refer to Servicing Areas ‐ Minimum.  representative. Every site is different and you may still be able to install the  However note that installing the ATM in the minimum servicing area may  ATM but with further increases to servicing and/or upgrading time. increase the servicing and/or upgrading time over a ATM installed using the  optimum area.  If you install in the minimum area then note that doors can open, and devices  rack out, beyond the area shown. Always leave as much space as possible  Always leave as much space as possible around the ATM to facilitate safe  around the ATM to facilitate safe operation and servicing. operation and servicing. 1780 mm Minimum clearance (70.08 in.) Additional clearances required for: 525 mm 25 mm (20.67 in.) (0.98 in.)
  • Page 30: Clearances - Corridor

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ UL, Short Sleeve 11 ‐ 5 CLEARANCES ‐ CORRIDOR CLEARANCES ‐ EXTERIOR WALL INTERNAL SPACE CONSTRAINT FOR THIRD‐PARTY CAMERA The dimensions shown assume the ATM is being moved using equipment that  If a third‐party camera is to be installed, it must fit within the space constraint  does not extend beyond the ATM or packaging. shown below.  Standard Collar A surrounding clearance of 6 mm (0.24 in.) has been allowed in the dimensions. 10 mm (0.39 in.) 30 mm 60 mm (1.81 in.) (2.36 in.) 45 mm (1.77 in.) 30 mm 30 mm (1.18 in.) (1.18 in.) 60 mm 150 mm Advert Collar...
  • Page 31: Variant Details - Ul, Standard Sleeve

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ UL, Standard Sleeve 12 ‐ 1 PACKAGE DIMENSIONS COLLAR DIMENSIONS HOLE IN THE WALL It is the responsibility of the owning institution to ensure that the heights from  977 mm the sidewalk level to the facia items comply with any local regulations. Where  Standard 1435 mm (38.46 in.) no such regulations exist, the ATM can be installed at the NCR optimum height. 47 mm (56.50 in.) (1.85 in.) 63 mm For correct installation height you must consider the difference in height  725 mm (2.48 in.) (28.54 in.) between the sidewalk and the interior floor. If there is no difference then the  38 mm plinth must have the height specified in the illustrations below. (1.50 in.) 725 mm 1836 mm (28.54 in.)
  • Page 32: Security Bolts

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ UL, Standard Sleeve 12 ‐ 2 SECURITY BOLTS BOLT HOLES CABLE ENTRY Bolts and anchors must be supplied by the owning organisation. The ATM should be bolted to the floor or plinth, through all the holes marked  770 mm ‘A’, using four bolts with anchor washers. (30.31 in.) To meet security standards the ATM must be bolted to the floor, through all of  the bolt holes, using bolts with anchor washers as specified below. Bolts and  anchor washers are to be supplied by the owning organisation. 770 mm 165 mm (30.31 in.) (6.50 in.) Make sure that the floor or plinth is capable of withstanding the loading  408 mm 36 mm imposed by the anchor points for these bolts. Security Enclosure Ø 25 mm (16.06 in.) (1.42 in.) 30 mm (0.98 in.)
  • Page 33: Facia Items

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ UL, Standard Sleeve 12 ‐ 3 FACIA ITEMS Heights and Depths Distance for Voice Guidance Height Depth Facia Item from base from front of ATM of collar Distance from Facia Item 1111 mm 36 mm No. 5 Key Statement Exit (43.75 in.) (1.42 in.) 7 6 5 1115 mm...
  • Page 34: Servicing Areas - Optimum

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ UL, Standard Sleeve 12 ‐ 4 SERVICING AREAS ‐ OPTIMUM SERVICING AREAS ‐ MINIMUM The optimum servicing area provides the best access to the ATM for all  This is the minimum area required for operating and servicing the ATM. servicing and operation tasks. Wherever possible the ATM should be installed within the optimum servicing  Wherever possible the ATM should be installed within the optimum servicing  area. Installing the ATM in the minimum servicing area may increase the  area. servicing and/or upgrading time.  If the optimum area is not available then refer to Servicing Areas ‐ Minimum.  If the minimum area is not available then consult your local service  However note that installing the ATM in the minimum servicing area may  representative. Every site is different and you may still be able to install the  increase the servicing and/or upgrading time over a ATM installed using the  ATM but with further increases to servicing and/or upgrading time. optimum area.  If you install in the minimum area then note that doors can open, and devices  Always leave as much space as possible around the ATM to facilitate safe  rack out, beyond the area shown. Always leave as much space as possible  operation and servicing. around the ATM to facilitate safe operation and servicing. Minimum clearance 1780 mm Additional clearances required for: (70.08 in.) 525 mm 25 mm Cash Acceptor/Recycler or Scalable Deposit Module (LH side) (20.67 in.)
  • Page 35: Clearances - Corridor

     NCR SelfServ™ 34 Drive‐Up ATM Site Preparation Variant Details ‐ UL, Standard Sleeve 12 ‐ 5 CLEARANCES ‐ CORRIDOR CLEARANCES ‐ EXTERIOR WALL INTERNAL SPACE CONSTRAINT FOR THIRD‐PARTY CAMERA The dimensions shown assume the ATM is being moved using equipment that  If a third‐party camera is to be installed, it must fit within the space constraint  does not extend beyond the ATM or packaging. shown below.  Standard Collar  A surrounding clearance of 6 mm (0.24 in.) has been allowed in the dimensions. 10 mm (0.39 in.) 30 mm 60 mm (1.81 in.) (2.36 in.) 45 mm (1.77 in.) 30 mm 30 mm (1.18 in.) (1.18 in.) 60 mm 180 mm Advert Collar...