Table of Contents

Advertisement

Quick Links

TM
NCR SelfServ
32 ATM
Site Preparation
B006-6585-B000
0808

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SelfServ 32 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NCR SelfServ 32

  • Page 1 NCR SelfServ 32 ATM Site Preparation B006-6585-B000 0808...
  • Page 2: Federal Communications Commission (Fcc) Radio Frequency Interference Statement

    If this equipment does cause interference, which can be determined by turning the equipment off and on, the user is encouraged to consult an NCR service representative immediately.
  • Page 3: Table Of Contents

    Table of Contents NCR SelfServ 32 ATM Site Preparation INTRODUCTION .......................1 How to Use This Site Preparation Bookset ..............2 Purpose and Audience ....................2 Site Compliance......................2 Customer Responsibilities ....................3 Product Identification .....................4 PACKAGE DIMENSIONS....................5 Manoeuvring the ATM Into Position................6 Manoeuvring an Unpackaged Front Access ATM ............7 Manoeuvring an Unpackaged Rear Access ATM............8...
  • Page 4 Facia Opening Clearance ..................24 Hot Air Outlets - Front Access ..................25 Hot Air Outlets - Rear Access ..................26 REQUIREMENTS FOR THE FLOOR................27 Floor Covering ......................27 Floor Loading .......................27 BOLT HOLE LOCATIONS .....................28 Front Access .........................28 UL Security Enclosure Bolt Hole Locations............28 CEN Security Enclosure Bolt Hole Locations............29 Rear Access........................30 UL Security Enclosure Bolt Hole Locations............30...
  • Page 5: Introduction

    NCR SelfServ 32 ATM Site Preparation INTRODUCTION The NCR SelfServ 32 Automated Teller Machine (ATM) is a freestanding interior ATM that is available in front or rear access variants. In all illustrations within this manual, the front access will be used, except where the text relates specifically to the rear access.
  • Page 6: How To Use This Site Preparation Bookset

    How to Use This Site Preparation Bookset The site preparation is part of the NCR SelfServ 32 ATMs Site Preparation Bookset. It acts both as a specifications book, and also as a gateway to the other book in the bookset,...
  • Page 7: Customer Responsibilities

    NCR will not be liable in respect of any comment, suggestion or advice given by its staff or in respect of any failure to give advice.
  • Page 8: Product Identification

    NCR SelfServ 32 ATM Site Preparation Provide floor coverings and environmental systems that limit or control static electricity build-up and discharge. Install the product at a height which meets the accessibility regulations of the relevant country. Product Identification The product is identified by the class number, 6632, and a 4 digit model number, which is printed on a label fixed inside the top-box of the ATM.
  • Page 9: Package Dimensions

    NCR SelfServ 32 ATM Site Preparation PACKAGE DIMENSIONS The dimensions of a packaged ATM, with and without the carton and lid, are shown below. 977 mm 1435 mm (38.5 in.) (56.5 in.) 1836 mm (72.3 in.) 1779 mm (70.0 in.)
  • Page 10: Manoeuvring The Atm Into Position

    NCR SelfServ 32 ATM Site Preparation Manoeuvring the ATM Into Position Ensure that doorways and corridors leading to your point of installation are wide enough to allow the package to pass through, or make arrangements to unpack the ATM in an area with sufficient access and then move it to the installation site.
  • Page 11: Manoeuvring An Unpackaged Front Access Atm

    NCR SelfServ 32 ATM Site Preparation Manoeuvring an Unpackaged Front Access ATM The following table gives the minimum dimensions for doorways, corridors with right angle corners and the space required to rotate an unpackaged ATM on its axis. Note 1: The dimensions assume the ATM is being moved using equipment that does not extend beyond the ATM or packaging.
  • Page 12: Manoeuvring An Unpackaged Rear Access Atm

    NCR SelfServ 32 ATM Site Preparation Manoeuvring an Unpackaged Rear Access ATM The following table gives the minimum dimensions for doorways, corridors with right angle corners and the space required to rotate an unpackaged ATM on its axis. Note 1: The dimensions assume the ATM is being moved using equipment that does not extend beyond the ATM or packaging.
  • Page 13: Atm Dimensions

    NCR SelfServ 32 ATM Site Preparation ATM DIMENSIONS The following illustrations show dimensions for ATMs configured with CEN Grade L, CEN Grade I, CEN Grade III, CEN Grade IV Spanish Certified and UL 291 Level 1 security enclosures. Refer to page 28 for the dimensions of the cable access hole.
  • Page 14: Front Access With Extended Rear Panel

    NCR SelfServ 32 ATM Site Preparation Front Access with Extended Rear Panel For some front access configurations, such as with the Dual Roll Receipt Printer, the rear panel has an extra extension increasing the overall depth of the ATM. The illustration...
  • Page 15: Rear Access

    NCR SelfServ 32 ATM Site Preparation Rear Access UL Security Enclosure The illustration below shows the dimensions for a rear access ATM configured with a UL security enclosure. 65 mm (2.5 in.) 7 mm 217 mm (0.3 in.) (8.5 in.) 1636 mm (64.4 in.)
  • Page 16: Cen Security Enclosure

    NCR SelfServ 32 ATM Site Preparation CEN Security Enclosure The illustration below shows the dimensions for a rear access ATM configured with a CEN Grade L, CEN Grade I, CEN Grade III or CEN Grade IV Spanish Certified security enclosure.
  • Page 17: Privacy Panels

    NCR SelfServ 32 ATM Site Preparation Privacy Panels The illustration below shows the ATM with privacy panels fitted to either side of the facia. The dimensions are the same for ATMs configured with a CEN Grade L, CEN Grade I, CEN Grade III, CEN Grade IV Spanish Certified or UL Level 1 security enclosure.
  • Page 18: Access For All

    NCR SelfServ 32 ATM Site Preparation ACCESS FOR ALL The ATM has been designed to meet the height and reach requirements of both the able- bodied and the disabled. For wheelchair users, the ATM offers optimised parallel approach, providing easy access, security and private space if installed according to the specifications detailed in this document.
  • Page 19 NCR SelfServ 32 ATM Site Preparation 954 mm 121 mm Contactless Card Reader (37.6 in.) (4.8 in.) 1039 mm 152 mm Card Reader (40.9 in.) (6.0 in.) 1154 mm 170 mm Receipt (45.4 in.) (6.7 in.) 1193 mm 193 mm Statement Exit or Passbook Entry and Exit (47.0 in.)
  • Page 20: Topmost Viewable Facia Item

    NCR SelfServ 32 ATM Site Preparation Topmost Viewable Facia Item The following illustration shows the projected angle from the front of the ATM facia to the topmost viewable facia item. ° Statement B006-6585-B000...
  • Page 21: Facia Item Locations For Voice Guidance

    NCR SelfServ 32 ATM Site Preparation Facia Item Locations for Voice Guidance Facia Item Distance from No. 5 Key Clock Face Position 232 mm Fingerprint Reader (9.1 in.) Cash Exit and/or Entry or Envelope Exit and/ 152 mm or Entry (6.0 in.)
  • Page 22: Task Lighting

    NCR SelfServ 32 ATM Site Preparation 310 mm Audio Jack Plug (12.2 in.) Cash Exit or 177 mm Envelope Exit and/or Entry (7.0 in.) Task Lighting A minimum of 200 LUX is required for task lighting. Wheelchair Clearance The following illustration shows the clearance required for wheelchair approach and turning circle.
  • Page 23: Installation And Service Clearances

    NCR SelfServ 32 ATM Site Preparation INSTALLATION AND SERVICE CLEARANCES Important Notice to Users If it is likely that the ATM will be upgraded with new modules as they become available, you should use the optimum clearances. Note 1: Increasing the area around the ATM will improve service access.
  • Page 24: Optimum Clearances

    NCR SelfServ 32 ATM Site Preparation Optimum Clearances The following illustrations show the optimum areas required for installing and servicing the ATM. Front Access The illustration below shows the optimum clearance dimensions for a front access ATM configured with a UL or CEN security enclosure.
  • Page 25: Rear Access

    NCR SelfServ 32 ATM Site Preparation Rear Access The illustration below shows the optimum clearance dimensions for a rear access ATM configured with a UL or CEN security enclosure. 1856 mm (73.1 in.) 1285 mm (50.6 in.) 3015 mm (119.0 in.) 1730 mm (68.5 in.)
  • Page 26: Minimum Clearances

    NCR SelfServ 32 ATM Site Preparation Minimum Clearances The following illustrations show the minimum areas required for installing and servicing the ATM. Front Access The illustration below shows the minimum clearance dimensions for a front access ATM configured with a UL or CEN security enclosure.
  • Page 27: Rear Access

    NCR SelfServ 32 ATM Site Preparation Rear Access The illustration below shows the minimum clearance dimensions for a rear access ATM configured with a UL or CEN security enclosure. 1696 mm (66.8 in.) 1639 mm (64.5 in.) 1339 mm (52.7 in.) 1285 mm (50.6 in.)
  • Page 28: Facia Opening Clearance

    NCR SelfServ 32 ATM Site Preparation Facia Opening Clearance The illustration below shows the clearance required to open the facia. 857 mm 166 mm (33.7 in.) (6.5 in.) 216 mm (8.5 in.) Without Privacy Panels With Privacy Panels Front Access...
  • Page 29: Hot Air Outlets - Front Access

    NCR SelfServ 32 ATM Site Preparation Hot Air Outlets - Front Access The illustration below shows the position of the hot air outlets on the rear of the front access ATM. 529 mm (20.8 in.) 65 mm 89 mm (2.56 in.) (3.50 in.)
  • Page 30: Hot Air Outlets - Rear Access

    NCR SelfServ 32 ATM Site Preparation Hot Air Outlets - Rear Access The illustration below shows the position of the hot air outlets on the rear of the rear access ATM. 525 mm 125 mm (20.70 in.) (4.92 in.) 48 mm (1.89 in.)
  • Page 31: Requirements For The Floor

    NCR SelfServ 32 ATM Site Preparation REQUIREMENTS FOR THE FLOOR The ATM is suitable for mounting on a concrete or other non-combustible surface only. Floor Covering An antistatic floor covering should be used and must be of a type that will not generate dust or fluff.
  • Page 32: Bolt Hole Locations

    NCR SelfServ 32 ATM Site Preparation BOLT HOLE LOCATIONS The following illustrations show a plan of the base of the ATM (viewed from above). The plan should be used for pre-drilling bolt holes ‘A’ and illustrates the design of the steel plate, if used.
  • Page 33: Cen Security Enclosure Bolt Hole Locations

    NCR SelfServ 32 ATM Site Preparation CEN Security Enclosure Bolt Hole Locations The illustration below shows the dimensions for a front access ATM configured with a CEN security enclosure. 770 mm (30.3 in.) 774 mm (30.5 in.) 33 mm 65 mm (1.3 in.)
  • Page 34: Rear Access

    NCR SelfServ 32 ATM Site Preparation Rear Access UL Security Enclosure Bolt Hole Locations The illustration below shows the dimensions for a rear access ATM configured with a UL security enclosure. 770 mm (30.3 in.) 43 mm (1.7 in.) 33 mm 23 mm (1.3 in.)
  • Page 35: Cen Security Enclosure Bolt Hole Locations

    NCR SelfServ 32 ATM Site Preparation CEN Security Enclosure Bolt Hole Locations The illustration below shows the dimensions for a rear access ATM configured with a CEN security enclosure. 770 mm (30.3 in.) 65 mm 100 mm (2.6 in.) (3.9 in.)
  • Page 36: Security Bolts

    NCR SelfServ 32 ATM Site Preparation SECURITY BOLTS To meet security standards the ATM must be bolted to the floor, through the ‘A’ holes, using four bolts with anchor washers as specified below. The floor must be capable of withstanding the loading imposed by the anchor points for the bolts. Bolts and anchor washers are to be supplied by the owning organisation.
  • Page 37: Camera

    NCR SelfServ 32 ATM Site Preparation CAMERA Ambient Lighting If the ATM is fitted with a camera, it is strongly recommended that there is a minimum of 50 LUX lighting at floor level within the area illustrated below. 1000 mm (39.4 in.)
  • Page 38: Internal Space Constraint For Fitting A Third-Party Camera

    NCR SelfServ 32 ATM Site Preparation Internal Space Constraint for Fitting a Third-Party Camera If a third-party camera is to be installed, there is a space constraint to consider. The following illustration shows the space constraint dimensions. A list of cameras that will fit within this space constraint can be found in the ATMs Feature Descriptions (B006-6451) book.
  • Page 39: Decals

    NCR SelfServ 32 ATM Site Preparation DECALS This section provides specifications for the decals which you may wish to fit to the front of your ATM. Card Orientation Window If the window next to the Card Reader entry/exit slot is to be customised to indicate card orientation, the card/decal to be inserted into the window should be of the following dimensions.
  • Page 40: Standard Or Enhanced Advert Light

    NCR SelfServ 32 ATM Site Preparation Standard or Enhanced Advert Light The following illustrations show dimensions for an advert decal that can be placed on either the front or the inside of the window, depending on whether the window is opaque or clear.
  • Page 41: Entry/Exit Decals

    NCR SelfServ 32 ATM Site Preparation Entry/Exit Decals There are no recesses on the facia for entry/exit decals. However, if you wish to fit your own, the following are guidelines to the decal sizes, design and placement. Decal Size and Design The decals should be a maximum of 0.5 mm (0.02 in.) thick and it is recommended that...
  • Page 42: Decal Placement

    NCR SelfServ 32 ATM Site Preparation Decal Placement The recommended placement of the decals is above or below the entry/exit slots, determined by the space available near the slot. Cheque Deposit Statement Bulk Cheque Deposit Receipt Envelope Deposit Envelope Deposit...
  • Page 44 To help NCR maintain the quality of their publications, send comments on the accuracy, clarity, usability, navigation, organization, and value of this book. Address correspondence to: Surface mail address: NCR Financial Solutions Group Ltd Information Solutions Kingsway West Dundee Scotland...

Table of Contents