Page 1
NCR SelfServ ™ 28 ATM Site Preparation B006-6884-A000 April 2010...
Page 2
All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances, photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR office for information that is applicable and current.
Table of Contents NCR SelfServ 28 ATM Site Preparation INTRODUCTION .......................1 How to Use This Site Preparation Bookset ..............2 Purpose and Audience ....................2 Site Compliance......................2 Customer Responsibilities ....................3 Product Identification .....................4 ATM Location ........................4 PACKAGE DIMENSIONS....................5 Packaged ATM .......................5 Pallet, Carton and Lid ....................5 Pallet and Carton......................6...
Page 4
REQUIREMENTS FOR THE FLOOR................22 Floor Loading .......................22 BOLT AND CABLE ENTRY HOLE LOCATIONS ............23 Bolt Holes ........................23 Cable Entry Recess .......................24 SECURITY BOLTS ......................25 PROTECTION BOLLARDS ....................26 VIDEO CAMERA......................27 Ambient Lighting......................27 Internal Space Constraint for Fitting a Third-Party Video Camera......28 DECALS..........................29 Card Orientation Window.....................30 Advert Recess .......................31...
NCR SelfServ 28 ATM Site Preparation INTRODUCTION With Air Conditioner Without Air Conditioner The NCR SelfServ 28 is a free-standing, weatherised ATM designed for exterior use which is replenished from the front. Note: All dimensions are rounded to the nearest millimetre. B006-6884-A000...
How to Use This Site Preparation Bookset The site preparation is part of the NCR SelfServ 28 ATMs Site Preparation Bookset. It acts both as a specifications book, and also as a gateway to the other books in the bookset,...
NCR SelfServ 28 ATM Site Preparation Provide floor coverings and environmental systems that limit or control static electricity build-up and discharge. Install the product at a height which meets the accessibility regulations of the relevant country. Product Identification The illustration below shows the layout of the product identification label which is fixed inside the top-box of the ATM.
NCR SelfServ 28 ATM Site Preparation PACKAGE DIMENSIONS Packaged ATM The dimensions of a packaged ATM, with and without the carton and lid, are shown below. Pallet, Carton and Lid 805 mm 1420 mm (31.69 in.) (55.91 in.) AFFIX LABELS HERE...
NCR SelfServ 28 ATM Site Preparation Pallet and Carton 795 mm 1400 mm (31.30 in.) (55.12 in.) AFFIX LABELS HERE LPN No: Carton No: 445-0715704 SelfServ 1812 mm DO NOT STACK (71.34 in.) THIS WAY UP CONTENTS WILL BE CONTENTS WILL BE...
NCR SelfServ 28 ATM Site Preparation Manoeuvring the ATM into Position Ensure that doorways and corridors leading to your point of installation are wide enough to allow the package to pass through, or make arrangements to unpack the ATM in an area with sufficient access and then move it to the installation site.
NCR SelfServ 28 ATM Site Preparation Manoeuvring an Unpackaged ATM The following table gives the minimum dimensions for doorways, corridors with right angle corners and the space required to rotate on its axis an unpackaged ATM. Note 1: The dimensions assume the ATM is being moved using equipment that does not extend beyond the ATM or packaging.
NCR SelfServ 28 ATM Site Preparation ATM DIMENSIONS The following illustrations show dimensions for ATMs configured with a CEN Grade 1 or CEN Grade L security enclosure. Note: Cables enter the ATM through the hole in the base of the ATM security enclosure.
NCR SelfServ 28 ATM Site Preparation Without Air-conditioning Unit The illustration below shows the dimensions of the Selfserv 28 without the air- conditioning unit. 490 mm (19.29 in.) 814 mm (32.05 in.) 1552 mm 1535 mm (61.10 in.) (60.43 in.)
NCR SelfServ 28 ATM Site Preparation With Air-conditioning Unit The illustration below shows the admissions of the Selfserv 28 with the air-conditioning unit fitted. 104 mm 490 mm (4.09 in.) (19.29 in.) 389 mm (15.31 in.) 814 mm (32.05 in.) 122 mm (4.80 in.)
NCR SelfServ 28 ATM Site Preparation ACCESS FOR ALL The ATM has been designed to meet the height and reach requirements of both the able- bodied and the disabled. For wheelchair users, the ATM offers optimised parallel approach, providing easy access, security and private space if installed according to the specifications detailed in this document.
NCR SelfServ 28 ATM Site Preparation Height and Depth to Main Facia Items All height dimensions are calculated from the base of the ATM. Height Depth from Facia Item (CEN L and CEN I) front of shelf 1302 mm 203 mm 381 mm (15.0 in.)
NCR SelfServ 28 ATM Site Preparation Topmost Viewable Facia Item The following illustration shows the projected angle from the front of the ATM facia to the topmost viewable facia item. Touchscreen Display B006-6884-A000...
NCR SelfServ 28 ATM Site Preparation Facia Item Locations for Voice Guidance Facia Item Distance from No. 5 Key Clock Face Position 118 mm Receipt Exit (4.6 in.) 325 mm 381 mm (15.0 in.) Display - Top left-hand FDK (12.8 in.) 315 mm 307 mm (12.1 in.) Display - Top left-hand FDK...
NCR SelfServ 28 ATM Site Preparation Task Lighting A minimum of 200 lux is required for task lighting. Wheelchair Clearance The following illustration shows the clearance required for wheelchair approach and turning circle. 1550 mm (61.0 in.) 1550 mm (61.0 in.)
NCR SelfServ 28 ATM Site Preparation INSTALLATION AND SERVICE CLEARANCES Important Notice to Users The following illustrations shows the areas required for installing, servicing and replenishing the ATM. If it is likely that the ATM will be upgraded with new modules as they become available, you should use the stated clearances.
NCR SelfServ 28 ATM Site Preparation Without Air Conditioner The illustration below shows the area required for installing, servicing and replenishing the ATM with no air conditioner fitted. 712 mm (28.03 in.) 111 mm 111 mm (4.37 in.) (4.37 in.) 242 mm (9.53 in.)
NCR SelfServ 28 ATM Site Preparation With Air Conditioner The illustration below shows the area required for installing, servicing and replenishing the ATM with the air conditioner fitted. 712 mm (28.03 in.) 111 mm 111 mm (4.37 in.) (4.37 in.) 242 mm (9.53 in.)
NCR SelfServ 28 ATM Site Preparation Facia Clearance The following illustration shows the minimum clearance required to fully open the facia. 547 mm 238 mm (21.54 in.) (9.37 in.) 617 mm (24.29 in.) 92 mm (3.62 in.) 2214mm (87.17 in.) 631 mm (24.84 in.)
NCR SelfServ 28 ATM Site Preparation Air Vents The following illustrations show the position of the air vents on the ATM. Do not cover or block the vents. Without Air Conditioner 155 mm 202 mm 202 mm 274 mm (6.10 in.) (7.95 in.)
NCR SelfServ 28 ATM Site Preparation REQUIREMENTS FOR THE FLOOR The ATM is suitable for mounting on a concrete or other non-combustible surface only. The surface on which the ATM is to be sited should be level and even. Floor Loading The ATM must be installed on a floor capable of supporting the maximum weight.
NCR SelfServ 28 ATM Site Preparation BOLT AND CABLE ENTRY HOLE LOCATIONS Bolt Holes The following illustration shows a plan view of the base of the ATM which can be used for pre-drilling bolt holes. Bolt holes are marked ‘A’ and the cable entry hole marked ‘B’. The hole marked with ‘C’...
NCR SelfServ 28 ATM Site Preparation Cable Entry Recess Cables enter the ATM through a hole in the base of the security enclosure. There should be a cable entry recess, in the floor, of sufficient size to allow the cables to be coiled ready to be brought into the security enclosure.
NCR SelfServ 28 ATM Site Preparation SECURITY BOLTS To meet security standards the ATM must be bolted to the floor, through the ‘A’ holes shown in the illustrations in the bolt holes section, using six bolts with anchor washers as specified below.
NCR SelfServ 28 ATM Site Preparation PROTECTION BOLLARDS If protection bollards are to be fitted they should be positioned as shown in the illustration below. The bollards should be no wider than 102 mm (4.0 in) in diameter. The illustration below shows the position of the bollards relative to the ‘A’ bolt holes.
NCR SelfServ 28 ATM Site Preparation VIDEO CAMERA Ambient Lighting If the ATM is fitted with a video camera, it is strongly recommended that there is a minimum of 50 lux lighting at floor level within the area illustrated below.
NCR SelfServ 28 ATM Site Preparation Internal Space Constraint for Fitting a Third-Party Video Camera If a third-party video camera is to be installed within the ATM, there is a space constraint to consider. The following illustration shows the space constraint dimensions.
NCR SelfServ 28 ATM Site Preparation DECALS This section provides specifications for the decals which you may wish to fit to the front of your ATM. Advert Recess Card Orientation Window B006-6884-A000...
NCR SelfServ 28 ATM Site Preparation Card Orientation Window If the window next to the Card Reader entry/exit slot is to be customised to indicate card orientation, the card/decal to be inserted into the window should be of the following dimensions.
NCR SelfServ 28 ATM Site Preparation Advert Recess The following illustrations show dimensions for an advert decal that can be placed on the front of the product depending on whether the ATM is fitted with a camera. Recessed Area for Decal - with Camera Lens 10.7 mm...
NCR SelfServ 28 ATM Site Preparation Entry/Exit Slot Decal There are no recesses on the facia for entry/exit decals. However, if you wish to fit your own, the following are guidelines to the decal sizes, design and placement. Decal Size and Design The decals should be a maximum of 0.5 mm (0.02 in.) thick and it is recommended that...
NCR SelfServ 28 ATM Site Preparation Decal Placement The recommended placement of the decals is above or below the entry/exit slots, determined by the space available near the slot. Receipt Cash Dispense/Deposit B006-6884-A000...
Page 38
NCR SelfServ 28 ATM Site Preparation B006-6884-A000...
REVISION RECORD Date Page Description of Change March 10 New publication...
Page 40
To help NCR maintain the quality of our publications, please send feedback on the accuracy, clarity, usability, navigation, organization, and value of this book. Send your comments to: Email address: userfeedback@exchange.scotland.ncr.com Surface mail address: NCR Financial Solutions Group Ltd Information Solutions...
Need help?
Do you have a question about the SelfServ 28 and is the answer not in the manual?
Questions and answers