14.3

SOS alerts

15. Power Management

The ZOLEO communicator has a sleep mode, designed to reduce unnecessary power
consumption. By default, the ZOLEO device checks for messages every 12 minutes or when
sending a message and then returns to sleep. This default can be changed in the
settings.
15.1

Power-saving settings

If you want to change this default setting, ensure that your ZOLEO communicator and ZOLEO
App are connected and navigate to Device Settings in the ZOLEO App.
Table: Power-saving options
Option
Always on
Periodic - 12 mins
Periodic - 24 mins
Periodic - 60 mins
Manual
15.2

Low-battery warning

When the charge remaining in the battery is less than 10%, a warning symbol appears on the
status bar of a connected ZOLEO App and the
light up amber and a descending tone will be emitted at regular intervals. If you intend to use,
or keep using, the ZOLEO communicator, you should recharge the battery as soon as possible.
Battery usage
Receive message
performance
worst
best
best
Messages are received as soon as they are sent
Check for messages every 12 minutes
Check for messages every 24 minutes
Check for messages every 60 minutes
Messages are only received when you:
worst
power LED
on the ZOLEO communicator will
Power-saving
Description
request a message check or
send a message.