Electrolux EQWP4510IK Manual page 35

Hide thumbs Also See for EQWP4510IK:
Table of Contents

Advertisement

Available languages

Available languages

x4
• Seal the gap between the worktop and
glass ceramic with silicone.
• Put some soapy water on the silicone.
8.5 The installation of more than one appliance
Added parts:connection bar(s), heat re-
sistant silicon, rubber shape, sealing
strap.
+
580 mm
360 mm
-
=
20 mm
920 mm
min. 20 mm
• Pull off the excess silicone with the
scraper.
Only use special a heat - resistant
silicon.
The worktop cut out
Distance from the wall : minimum 50 mm
Depth : 490 mm
Width : sum widths of all the appliances
to be built-in and subtract 20 mm (see al-
so "Overview of all appliance widths" )
The installation of more than one appli-
ance
1.
Put down the dimension of the work-
top cut out and saw it out.
2.
Put the appliances one at time on
some soft surface, a blanket for ex-
ample, with the bottom side up.
3.
Put the seal stripe around the lower
edge of the appliance along the outer
edge of the glass ceramic.
4.
Loosely screw the fixing plates into
the appropriate holes in the protec-
tive casing.
5.
Put the first appliance in the worktop
cut out. Put the connection bar in the
worktop cut out and push up half of
the width against the appliance.
ENGLISH
35
min.
30 mm
min.
2 mm

Advertisement

Table of Contents
loading

Table of Contents