Installation - for contractors
9. Preparations
» Flush the water line thoroughly.
Water installation
A safety valve is not required.
Taps
» Use suitable taps (see chapter "Appliance descrip-
tion / Accessories").
Note
Fitting the special aerator supplied provides an op-
timum water jet.
10. Installation
10.1 Installation site
Install the appliance in a room free from the risk of frost
and near the draw-off tap.
Ensure that the lateral fixing screws for the cover are
always accessible.
The appliance is suitable for undersink installation (water
connections at the top) and oversink installation (water
connections at the bottom).
DANGER Electrocution
The adjusting screw for setting the flow rate is 'live',
and the IP25 protection is only given when the appli-
ance back panel is fitted.
» Always fit the appliance back panel.
34
10.2 Installation options
10.2.1 Undersink installation
Non-pressurised, with non-pressurised tap
Pressure-tested, with pressure-tested tap