Setting The System; Part Setting The System; Unsetting The System; Resetting After An Alarm - GARDINER TECHNOLOGY GARDTEC 300 Series User Instructions

Table of Contents

Advertisement

GARDTEC
350
Users Manual
SETTING THE SYSTEM
To Fully Set the system proceed as follows:-
1)
2)
Enter a valid User code.
Leave the premises via the
authorised exit
route.
(The DAY LED will flash followed by the exit tone.
Any zones violated during exit will change the
exit tone and the appropriate L.E.D will indicate).
Note:
To abort setting during exit time re-enter the code.
PART SETTING THE SYSTEM
To Part Set the syste~ proceed as follows:-
1)
2)
3)
Enter a valid User code.
(The DAY LED will flash followed by the
exit tone)
.
If Part Set 1 is required Press 1 or
(The DAY LED will flash
slowly.
Zones
programmed as Part 1 will be removed)
If Part Set 2 is required Press 2 or
(The DAY LED will flash slowly. Zones
programmed as Part 2 will be removed)
If Part Set 3 -is required Press 3
(The DAY LED will flash slowly. Zones
programmed as Part 1 and Part 2 will
be removed).
Leave the premises via the authorised exit route (or retire to an unprotected
area).
Note:
If any of the above part sets have been programmed as silent by your
engineer the setting will be silent with a single beep as the system final-
ly sets.
Page 2
1
·I
GARDTEC
350
UNSETTING THE SYSTEM
Users Manual
To Unset the system proceed as follows:-
1)
2)
3)
Enter the premises via an authorised entry point (the entry tone will sound).
Proceed directly to the Control Panel and enter a valid User code (the entry
tone wifl stop and the DAY LED will illuminate).
If the alarm has been activated during the set period all the LEDs will flash
press NO to view the cause of alarm.
RESETTING AFTER AN ALARM
If the system is set, unset it as shown above and proceed as follows:-
1)
2)
After an alarm all the LEDs will be flashing. If you wish to view the cause of
alarm press
NO.
To Reset the system enter the Master code and start to set
the system.
Before the entry time expires enter a valid code to abort the setting
.
The
system is now reset.
USER PROGRAMMING MODE
To enhance the flexibility of the Gardtec 350 Control Panel there are five user pro-
grammable options available. When programming the User options the display is via
the five Zone L.E.Ds and the White legend is
used.
This is shown in Fig 2. below. It
should be noted the the user programming mode is only available to the Master user
(User 1 ).
Fig 2.
POWER □
DAY □
Z1
D
f]T:fWi'i=I
Z2D
Z3 D
l~~
Z4D
zs
f:1:rim
,m,
TAMPER
D
Page 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gardtec 350

Table of Contents