WARNINGS AND SAFETY PRECAUTIONS

WARNING! To minimise the risk of fire, electric shocks or
1.
The product must only be used for its intended purpose as described in this manual.
The product may not be combined, assembled or repaired with other parts (e.g.
pump and mattress), accessories or spare parts other than those described in this
manual or other documentation from Care of Sweden.
2.
Do not use the pump in wet rooms or where there is a risk of the pump coming into
contact with water or another liquid. Never handle a pump that has come into
contact with water/liquid. Pull the plug out of the electrical socket immediately and
send the product to an authorised service technician for servicing.
3.
DO NOT USE in the vicinity of or in contact with fire sources/hot surfaces, such as
fire, burning cigarettes or hot lamps. Although the product has undergone fire
testing, it could become damaged if it comes into contact with fire sources.
4.
Position and use the product in a manner that prevents it from becoming trapped or
damaged. NOTE: Be particularly aware of trapping damage when using bed rails.
5.
Never use the product if the pump power cable or plug is defective, the pump casing
is damaged, or it is not functioning properly. Contact a service technician for
examination and repair.
6.
Regularly check product functionality through a hand check (see section 3.4). Also
check that the comfort setting is correct as indicated in the table on the pump.
7.
Continual monitoring is required when the product is used for individuals needing
special supervision, such as children.
8.
The mattress is protected by a hygiene cover; avoid using multiple hygiene covers as
this can affect the vapor permeability of the mattress.
9.
The hygiene cover does not allow liquid or air to penetrate but is vapour permeable.
Make sure that the user is positioned correctly to avoid the risk of suffocation.
10. Prevent damage to the hygiene cover from sharp objects.
11. If the cover is supplied with handles on the long sides, theses handles are only to be
used for lifting and moving the mattress itself. All other use will be at your own
responsibility and is not covered by the product warranty.
12. In order to minimize the risk of wounds occurring on the feet, make sure that the
user doesn't come into contact with the hangers of the pump.
Read all instructions prior to use