mundoclima MUVR-C9 Installation & Owner's Manual

mundoclima MUVR-C9 Installation & Owner's Manual

Window air conditioner, cooling only

Advertisement

Quick Links

WINDOW AIR CONDITIONER
Installation & Owner's manual
MUVR-C9 COOLING ONLY
R32
CL20382 to CL20383
English
www.mundoclima.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MUVR-C9 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for mundoclima MUVR-C9

  • Page 1 WINDOW AIR CONDITIONER Installation & Owner's manual MUVR-C9 COOLING ONLY CL20382 to CL20383 English www.mundoclima.com...
  • Page 2: Table Of Contents

    CONTENTS Thank you for choosing air conditoner.Our design is based on the best eff- iciency and the lowest noise operation and it can keep the room comfortable. Please read this operating manual carefully before operating the unit and keep it for consultation.
  • Page 3: The Refrigerant

    3OHDVH UHDG WKLV RSHUDWLQJ PDQXDO FDUHIXOO\ EHIRUH RSHUDWLQJ WKH XQLW WR WKH PDWHULDO REMHFWV IRU UHIHUHQFH The Refrigerant To realize the function of the air conditioner unit, a special refrigerant circulates leads to explosion . It can &RPSDUHG WR FRPPRQ UHIULJHUDQWV 5 LV D QRQSROOXWLQJ UHIULJHUDQW ZLWK QR ORZHr 5 KDV JRW YHU\ JRRG WKHUPRG\QDPLF IHDWXUHV ZKLFK OHDG WR D UHDOO\ KLJK WARNING: 'R QRW XVH PHDQV WR DFFHOHUDWH WKH GHIURVWLQJ SURFHVV RU WR FOHDQ RWKHU WKDQ...
  • Page 4: Precautions

    Precautions Warning 7his appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 5: Installation

    Installation Installation precaution: Window type conditioner is so valuable and the improper installation of it will cause a lot of da- mage! Please associate the professional tech- nician to install the unit and don’t install it by yourself. Otherwise, we are not responsible for the damage like this.
  • Page 6 Installation procedure: 1) Remove the sticker from the front panel. 2) Put the unit into the installation hole. :KHQ LQVWDOOLQJ WKH XQLW LW VKRXOG EH VO Horizontal line DQWHG GRZQ WR WKH EDFN WR DYRLG WKH HQ largement of noise or vibration. (Slant 6~10mm between 6-10mm.) (Shown at right 7KH LQVWDOODWLRQ SODFH VKRXOG EH VWURQJ...
  • Page 7 Dimensions: Unit: mm > Drain water : Drain pan and drain hose need to be installed before using. Drain hose is not included in the products, you need to purchase it locally to satisfy your particular needs. Use the following procedure to install drain pan and drain hose.
  • Page 8: Notes For Installation

    Notes for installation Remove Before removing air conditioner to the other place, you Then it must be done under the direction of the profe- ssional technician. In addition, the charge of this must be paid. Noise enlargement of noise and vibration. 'RQ¶W SXW DQ\WKLQJ LQ IURQW RI WKH RXWOHW RI WKH XQLW to avoid increasing noise.
  • Page 9: Function

    Function Introduction Window type room air conditioners can Autumn Spring regulate the room temperature and dry the Summer Winter Room temp. room. It is convenient for your work, study and life. It can be widely used in residence, Wind direction so on.
  • Page 10: Power Requirement

    Power requirement Rated voltage : 220-240V~ 50Hz The electric components will be damaged when the voltage is too high. If the voltage is too low, the compressor will vibrate violently to damage the refrigerant system and easily cause the compressor and electric components not work. The ground must be connected.
  • Page 11: Part Identification

    Part identification Panel outlook picture, just for reference, please take the real unit as standard. Cabinet Air inlet (behind the louver front intake grille) Front intake Remote grille control panel Air direction adjustment positioning the vane to discharge the air upwards, downwards or straight out.
  • Page 12: Remote Control Operation Procedure

    Remote control operation procedure Buttons on remote controller ON/OFF button MODE button +/- button FAN button SWING button SLEEP button TIMER button Introduction for icons on display screen Timer on Timer off Sending signal auto operation swing operation cool operation sleep operation dry operation lock...
  • Page 13: Introduction For Buttons On Remote Controller

    Introduction for buttons on remote controller Note: 7KLV LV D JHQHUDO XVH UHPRWH FRQWUROOHU LW FRXOG EH XVHG IRU WKH DLU FRQGLWLRQHUV with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
  • Page 14 Introduction for buttons on remote controller FAN button Pressing this button can select fan speed circularly as: AUTO, SPEED 1 ( SPEED 2 ( ) , SPEED 3 ( ), SPEED 4 ( ) (unavailable in this air conditioner. Speed 4 is the same with speed 3.). AUTO SPEED 1 (equals to low fan speed) SPEED 2 (equals to mid fan speed)
  • Page 15 Introduction for buttons on remote controller Note: 5DQJH RI WLPH VHWWLQJ LV aK 7KH LQWHUYDO EHWZHHQ WZR PRWLRQV FDQ W H[FHHG V RWKHUZLVH WKH UHPRWH FRQ WUROOHU ZLOO H[LW VHWWLQJ VWDWXV Function introduction for combination buttons Child lock function 3UHVV ³´ DQG ³´ EXWWRQV VLPXOWDQHRXVO\ FDQ WXUQ RQ RU WXUQ RII FKLOG ORFN IXQFWLRQ :KHQ FKLOG ORFN IXQFWLRQ LV VWDUWHG XS /2&.
  • Page 16 Replacement of batteries in remote controller 1. Press the mark “ ” on back cover of batteries box cover for remote controller with fingers as shown in the fig, and then remove the batteries box cover along the arrow direction. Battery 2.
  • Page 17: Remote Control Panel

    Remote control panel Note: If wireless remote controller is lost, open the surface panel and operate manually. POWER BUTTON SIGNAL RECEIVER Operation starts when pressing this button, and stops when pressing this button again. MODE BUTTON SWING BUTTON Select the operation mode, AUTO, HEAT, COOL, FAN, Activate the automatic air swing function.
  • Page 18: Operation Tips

    Operation Tips Operation for comfort and economy Do not overcool the room te- Keep blind or curtains closed. Keep the room temp. uniform. mperature. This is not good Do not let sunshine enter the Adjust the vertical and horizo- for health and wastes electr- room directly when the air co- icity.
  • Page 19: Caution

    Caution Operations for safety and health 1) The plug must be accessible after the appliance is positioned. 2) Do not use this appliance in the laundry. 3) If the power cord is damaged, it must be replaced by the manufacture or its service agent in void of hazard.
  • Page 20 Always wait at Always wait at least 3 minutes before least 3 minutes. switching the air conditioner on again after you have switched it off during cooling or heating. Inappropriate treatment of the unit involves the risk of severe damages of people and material. Details to this refrigerant are found in chapter “refrigerant”.
  • Page 21: Care And Maintenance

    Care and maintenance Always turn off the air conditioner and main power supply before cleaning to ensure safety. Cleaning unit 1. Cut power of f before cleaning. Plug out only washed at least once every two weeks or as after air con- often as it needs cleaning.
  • Page 22: Troubleshooting Guide

    Troubleshooting guide Please check the following items before asking for repair, it saves your time andmoney. Fault phenomenon Trouble-shooting ,V WKHUH D SRZHU IDLOXUH" Air conditioner ,V WKH SOXJ RXW" dose not oper- ,V SRZHU IXVH RU VZLWFK RII " ate at all.
  • Page 23 WZKD h > & & & & & & & > & & &, > W, s W> ,K Z W& > > >W > & 1RWH ,I WKHUH UH RWKHU PDOIXQFWLRQ FRGHV SOHDVH FRQWDFW TXDOLILHG SURIHVVLRQDOV IRU VHUYLFH...
  • Page 24: After Service

    Immediately stop all operations and plug out, please contact your dealer in the following situations. 2SHUDWLRQ VWDUWV RU VWRSV DEQRUPDOOy. 3RZHU IXVH RU VZLWFK RIWHQ EUHDNV &DUHOHVVOy VSODVK ZDWHU RU VRPHWKLQg LQWR DLU FRQdLWLRQHU. (OHFWULFDO OLQHV DUH PXFK KRW RU OLQHV FRYHU EUHDNV 2WKHU VWUDQJH VLWXDWLRQV After service ,I \RXU DLU FRQGLWLRQHU KDV WKH TXHVWLRQV RI TXDOLW\ RU DQ\WKLQJ HOVH SOHDVH FRQWDFW...
  • Page 25: Safety Operation Of Flammable Refrigerant

    Safety operation of flammable refrigerant Qualification requirement for installation and maintenance man 1. All the work men who are engaging in the refrigeration system should bear the for dealing with the refrigeration system recognized by this industry. If it needs other technician to maintain and repair the appliance, they should be supervised 2.
  • Page 26 WHOGLQJ 1. If you should cut or weld the refrigerant system pipes in the process of maintain- ing, please follow the steps as below a. Shut down the unit and cut power supply b. eliminate the refrigerant c. vacuuming d. clean it with N e.
  • Page 27 Notes...
  • Page 28 C/ NÁPOLES 249 P1 08013 BARCELONA ESPAÑA / SPAIN (+34) 93 446 27 80 SAT: (+34) 93 652 53 57 66129932725 www.mundoclima.com...

Table of Contents