Checking that the system is operating correctly
9
8
10
12
Check every day that the DSES system is working correctly. To do this :
1- Put the conductive glove no. 8 on as shown above.
2- Switch on your pruning shear by pressing the button no. 10.
3- Check that pruning shears is not indicating a fault (If the led no. 9 is red and that the Data base
indicates a fault D07, see the "DSES fault indication" box below).
4- With the glove no. 8, flat down without the hand inside, come in contact with the pruning shear
hook. The blade must open or not close when the trigger no. 12 is operated.
DO NOT FOR ANY REASONS, TEST THE GLOVE WITH THE HAND INSIDE
If the DSES system is working correctly, the pruning shear should not close in any circumstances
As well as carrying out daily checks, you should also carry out visual checks to ensure that the
conductive glove is in good overall condition. It is also necessary to machine-wash the conductive glove
(max. 30°) once a week in order to maintain optimum conductivity. Replace the glove(s) if worn.
INFACO may not be held liable for any faults caused by the poor condition of the gloves.
DSES fault indications
9
11
10
Indication on LED no. 10 on the pruning shears :
permanent red LED and the pruning shear works.
Indication reading pruning shear : Fault D07 (only by your dealer via the « interface »).
The permanent red LED on the pruning shear and the fault D-07 displayed in the Data base
show the user that there is a fault in the DSES system.
The secateurs will still operate when the permanent red LED and fault D-07 are showing BUT
the user is no longer protected by the system
In the event of a fault :
1- Press the button no. 10 until the LEDS turn off and disconnect the secateurs at socket no. 11.
2- Check that tongue no. 2 is correctly fixed to the Velcro of the conductive glove no. 8. Check the condition
of the DSES wire.
3- Follow the procedure set out above to check that the DSES is operating correctly.
Special case: the DSES system may still be operating even if the LED on the pruning shear is red.
If the pruning shears and the DATA base are still indicating an DSES fault, contact the retailer
who sold you the appliance.