9
Connect the cables to the terminals as seen in the picture.
Note
Each wire is labeled with the corresponding terminal number.
Indoor unit
Outdoor unit
Outdoor unit
CAUTION
End of the wire must be circular.
After connecting the cables, make sure terminal numbers on
the indoor/outdoor unit matches.
Screws on terminal block must not be unscrewed with the
torque less than 12kgf•cm.
10
Connect the grounding conductor to the grounding terminals.
11
Close the terminal board cover by tightening the screw carefully.
12
Connect the power cable to the indoor unit.
In Russia and Europe, consult with the supply authority to
Note
determine the supply system impedance before installation.
WARNING
T he terminal is connected too firmly , the terminal may be damaged.
C onnect the wires firmly so that wires can not be pulled out easily.
(If they are loose, it could cause burn-out of the wires.)
C onnect the wires according to color codes, referring to the wiring
diagram.
Indoor unit
1(L)
2(N)
F1
F2
1 2
F1 F2
Earth
terminal
1 2
F1 F2
1(L) 2(N)
F1 F2
I
A
NSTALLING THE
IR CONDTIONER
9
E-