Installing and Connecting the Drain Hose of the Indoor Unit

When installing the drain hose for the indoor unit, check if condensation
draining is adequate. When passing the drain hose through the 65-mm hole
drilled in the wall, check the followings:
Wall
Indoor unit
Drain hose
The drain hose must not be
bent.
Drain hose installation:
1
If necessary, connect the 2-meter extension drain hose to the drain hose.
2
If you use the extension drain hose, insulate the inside of the extension drain
hose with a shield.
3
Fit the drain hose into 1 of 2 drain hose holes, then fix the end of the drain
hose tightly with a clamp.
Note
If you do not use the other drain hose hole, block it with a rubber
stopper.
4
Pass the drain hose under the refrigerant pipe, keeping the drain hose tight.
5
Pass the drain hose through the hole in the wall. Check if it slants downwards
as seen in the picture.
CAUTION
 M ake sure the installed direction of the drain hose is correct.
Inadequate installation may cause condensate water leakage.
 I f the drain hose is routed inside the room, insulate the hose so that
dripping condensation does not damage the furniture or floors.
 D O NOT WALL UP THE DRAIN HOSE CONNECTION !
Drain hose connection must be easy accessible and serviceable
The drain hose must
The end of the drain hose
NOT slant upwards.
must NOT be placed under
water.
5cm
less
Keep a clearance of at least
Do NOT place the end of the
5cm between the end of the
drain hose in a hollow.
drain hose and the ground.