A
NSTALLING THE
IR CONDTIONER

Connecting the Assembly Cable

8
E-
Screw
Unfasten Torque
M4
M5
Connecting the cable
 When you install the unit, make first refrigerant connections and then elec-
trical connections. Connect the air conditioner to grounding system before
performing the electrical connection. If unit is uninstalled first disconnect
electrical cables, then refrigerant connections.
1
Extend the assembly cable if necessary.
CAUTION Do not connect two or more different cables to extend the
length. It may cause fire.
2
Open the front grille.
3
Remove the screw securing the connector cover.
4
Pass the assembly cable through the rear of the indoor unit and connect the
assembly cable to terminals. (Refer to the picture in page 9.)
Note
Each wire is labeled with the corresponding terminal number.
5
Pass the other end of the cable through the 65mm hole in the wall.
6
Close the connector cover by tightening the screw carefully.
7
Close the front grille.
8
Remove the terminal board cover on the side of the outdoor unit.
Torque(kgf . cm)
Tighten Torque
17~30
25~40
20~35
30~50