Replacement Main Body for EPL-HB-50LED-RT Light Fixture
Thank you for your purchase of the Larson Electronics EPL-HB-50LED-RT-SP0122.
WARNING:
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
CRITICAL SAFETY INSTRUCTIONS:
INSTALLATION SHOULD ONLY BE CONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY
RELEVANT LOCAL BUILDING CODES.
RISK OF FIRE OR ELECTRIC SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF FIXTURE'S ELECTRICAL
SYSTEMS. IF NOT QUALIFIED, CONTACT A QUALIFIED ELECTRICIAN.
BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.
MAKE SURE THE SUPPLY VOLTAGE IS THE SAME AS THE FIXTURE'S RATED VOLTAGE.
TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP
OBJECTS. SUITABLE FOR DAMP LOCATIONS.
Replacement Main Body for EPL-LB-50LED-RT Light Fixture - No Mount Included.
This explosion proof light is designed for illumination of industrial locations. It uses the latest in solid state lighting technology for long
life, low maintenance and high efficiency.
The unique design focuses the light where it is needed, giving improved efficiency over a conventional HID luminaire.
An internal, universal input, power-factor-corrected switch-mode supply allows it to be used from any nominal 100-277V AC supply
without any variation in light output.
WARNING
To avoid the risk of fire, explosion or electric shock, this product should be installed, inspected
and maintained by a qualified electrician only, in accordance with all applicable electrical codes.
To avoid electric shock:
Be certain electrical power is OFF before and during installation and maintenance.
Luminaire must be connected to a wiring system with an equipment-grounding conductor.
To avoid explosion:
Make sure the supply voltage is within the luminaires' voltage rating.
Ensure the marked T rating is less than the ignition temperature of the Hazardous Atmosphere.
Do not operate in ambient temperatures above those indicated on the luminaire nameplate.
Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.
For supply connections, use wire rated for at least 110°C Recommended
mounting height is 25-40 feet.
Larson Electronics, LLC
No Mount Included
Instruction Manual
Phone: (800) 369-6671
Fax: (903) 498-3364
EPL-HB-50LED-RT-SP0122
www.larsonelectronics.com
2 of 2

Advertisement

loading

Summary of Contents for Larson Electronics EPL-HB-50LED-RT-SP0122

  • Page 1 EPL-HB-50LED-RT-SP0122 Replacement Main Body for EPL-HB-50LED-RT Light Fixture No Mount Included Instruction Manual Thank you for your purchase of the Larson Electronics EPL-HB-50LED-RT-SP0122. WARNING: READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. CRITICAL SAFETY INSTRUCTIONS: INSTALLATION SHOULD ONLY BE CONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY •...
  • Page 2 Larson Electronics. THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT SALES@LARSONELECTRONICS.COM OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE.