INTRODUCTION
:
 This LED light is designed for illumination of industrial locations. It uses the latest in solid state
lighting technology for long life, low maintenance, and high efficiency.
 The unique optical design focuses light downward to where it is needed, giving improved
efficiency over a conventional HID luminaire.
 An internal, universal input, power-factor-corrected switch-mode supply allows it to be used
from any nominal 100V-277V supply without any variation in light output.
WARNINGS:
To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected and
maintained by a qualified electrician only, in accordance with all applicable electrical codes.
DO NOT let power cord touch hot surfaces.
DO NOT mount near gas or electric heaters.
Equipment should be mounted in locations and at heights where it will not be subjected to
tampering by unauthorized personnel.
The use of accessory equipment not recommended by the manufacture may cause an unsafe
condition.
DO NOT use this equipment for other than intended use.
To avoid electric shock:
Be certain electrical power is OFF before and during installation and maintenance.
Luminaire must be connected to a wiring system with an equipment-grounding conductor.
To avoid explosion:
Make sure the supply voltage is within the luminaires' voltage rating.
Ensure the marked T Rating is less than the ignition temperature of the Hazardous Atmosphere.
Do not operate in ambient temperatures above those indicated on the nameplate.
Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.
WARNING – Explosion Hazard – Substitution of components may impair suitability for Class I
Division 2 and Class II Division 1
Explosion Hazard – Do not disconnect equipment unless power has been switched off or the
area is known to be non-hazardous.
www.LarsonElectronics.com
EPLC2-24-50LED
sales@larsonelectronics.com

Advertisement

loading

Summary of Contents for Larson Electronics EPLC2-24-50LED

  • Page 1 9419 E US HWY 175, Kemp, TX 75143 - P: (800) 369-6671 - F: (903) 498-3364 EPLC2-24-50LED NOTICE: These instructions contain important safety information, read and follow them carefully. Larson Electronics will not accept any responsibility for injury, damage or loss which may occur due to incorrect installation, operation or maintenance. INTRODUCTION ...
  • Page 2 Larson Electronics LLC www.LarsonElectronics.com sales@larsonelectronics.com 9419 E US HWY 175, Kemp, TX 75143 - P: (800) 369-6671 - F: (903) 498-3364 INSTALLATION WARNING: The technical data indicated on the luminaire are to be observed.  Changes to the design and modifications of the luminaire are not permitted.
  • Page 3 Larson Electronics LLC www.LarsonElectronics.com sales@larsonelectronics.com 9419 E US HWY 175, Kemp, TX 75143 - P: (800) 369-6671 - F: (903) 498-3364 o The fixture is threaded for ¾” NPT, at the center and each end of the power supply housing, in order to be assembled to conduit.