Object 6148H: Ai Span Start; Object 6149H: Ai Span End - GE BAKER HUGHES DPS 5000 Series Instruction Manual

Can bus pressure transducer
Hide thumbs Also See for BAKER HUGHES DPS 5000 Series:
Table of Contents

Advertisement

Appendix A. CANopen Object Dictionary
A.3.11 Object 6148h: AI Span Start
This value specifies the lower limit where process values are expected. Process values, lower
than this limit, are marked as negative overloaded.
OBJECT DESCRIPTION
INDEX
Name
Object Code
Data Type
ENTRY DESCRIPTION
Sub-Index
Description
Access
PDO Mapping
Default Value
Sub-Index
Description
Data Type
Access
PDO Mapping
Default Value
Sub-Index
Description
Data Type
Access
PDO Mapping
Default Value
A.3.12 Object 6149h: AI Span End
This value specifies the upper limit where process values are expected. Process values
exceeding this limit are marked as positive overloaded.
OBJECT DESCRIPTION
INDEX
Name
Object Code
Data Type
50 | DPS 5000 Series Instruction Manual-English
6148
AI Span start
Array
REAL32
000
number of entries
RO
No
0.0
001
AI Span start 1
REAL32
RW
No
0.0
002
AI Span start 2
REAL32
RW
No
0.0
6149
AI Span end
Array
REAL32
© 2018 Baker Hughes, a GE company – All rights reserved.