Endress+Hauser Deltabar FMD71 Installation Instruction

Endress+Hauser Deltabar FMD71 Installation Instruction

Sensor cover and sensor electronics
Hide thumbs Also See for Deltabar FMD71:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Installation Instruction
Sensor cover and sensor electronics
Deltabar FMD71, FMD72
EA00064P/00/A2/02.13
71235700
Instruction is valid for the following spare part sets:
Order number
Device component
71186144
Cover Alu, sensor housing FMD71/72 , O-ring
71186147
Cover 316L, sensor housing FMD71/72, O-ring
71186142
Electronics sensor module FMD71/72
We recommend that the Installation Instructions be kept with the packaging at all times.
Confirmation whether the spare part is permitted to be used with the measuring device
The spare parts set and Installation Instructions are used to replace a faulty unit with a functioning unit of the same type. 
Use genuine parts from Endress+Hauser only.
Only original spare parts supplied by Endress+Hauser shall be used with the measuring device. Therefore, before use, check whether the spare
part set is compatible with the measuring device.
A spare parts overview label is located in the connection compartment cover of the measuring device. If there is no label or the spare part is not
listed the appropriate spare part can also be identified via W@M Device Viewer.
How carrying out such a check via the W@M Device Viewer is described below:
i
Choose the Endress+Hauser Device Viewer via web browser: www.endress.com/deviceviewer
Enter the serial number (Ser. No.) of the device into the W@M Device Viewer, then click on "Spare parts".
The list of the available spare parts for the device is displayed.
Check the order number on the packaging label of the spare part set.
Check whether the order number of the spare part set is specified in the list displayed by the device viewer:
= YES, the spare part can be used.
= NO, the spare part may not be used.
Ser. No.:12345
Ser.No.:1234567890
i
www.endress.com/deviceviewer
Device Viewer
Ser. No.: 12345
71235700
=
?

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Deltabar FMD71 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Endress+Hauser Deltabar FMD71

  • Page 1 The spare parts set and Installation Instructions are used to replace a faulty unit with a functioning unit of the same type.  Use genuine parts from Endress+Hauser only. Only original spare parts supplied by Endress+Hauser shall be used with the measuring device. Therefore, before use, check whether the spare part set is compatible with the measuring device.
  • Page 2: Overview Of The Personnel Authorized To Carry Out Repairs

    1, 2, 3 1 Trained customer technician 2 Service technician authorized by Endress+Hauser 3 Endress+Hauser (send measuring device back to manufacturer) Safety instructions • Check whether the spare part matches the identification label on the • Risk of damaging electronic components! Ensure you have a working measuring device, as explained on the first page.
  • Page 3 Sensor cover and sensor electronics Remove the Cover of sensor LP/HP Cover1 Cover2 Cover3 Re-assembly Re-assembly is carried out in reverse order, unless otherwise instructed.  The following must be noted: Cover4 Endress + Hauser...
  • Page 4: Tool List

    Sensor cover and sensor electronics Tool List Size 1, 2 20, 24, 26 mm Replacing the sensor electronics 24 mm 20 mm Cover1 Cover2 Electronics1 Electronics2 24 mm 24 mm 6.25 Nm 6.25 Nm 26 mm 24 mm 24 mm 3.75 Nm 3.25 Nm Electronics3...
  • Page 5: Die Einbauanleitung Ist Für Folgende Ersatzteilsets Gültig

    Analyse Einbauanleitung Sensor FMD71, FMD72 und Kabel Deltabar FMD71, FMD72 EA00066P/00/A2/03.13 71235704 Die Einbauanleitung ist für folgende Ersatzteilsets gültig: Bestellnummer Original-Ersatzteilset Verbindung von Verwendung XPP0008-######## Sensor FMD71 Deltabar FMD71 XPP0007-######## Sensor FMD72 Deltabar FMD72 71186132 Verbindungskabel L=6 ft; 1,82 m...
  • Page 6: Überprüfung, Ob Die Verwendung Des Ersatzteils Für Das Messgerät Erlaubt Ist

    Ersatzteilset und Einbauanleitung dienen dazu, eine defekte Einheit gegen eine funktionierende Einheit des gleichen Typs zu ersetzen.  Es dürfen nur Originalteile von Endress+Hauser verwendet werden. Grundsätzlich dürfen nur Ersatzteilsets verwendet werden, die von Endress+Hauser für das Messgerät vorgesehen sind. Vor der Verwendung ist deshalb zu überprüfen, ob das Ersatzteilset zum Messgerät passt.
  • Page 7 • Die in der Betriebsanleitung aufgeführten Hinweise zum Transport – Mit den jeweiligen Einsatzbedingungen der Geräte vertraut. und zur Rücksendung beachten. – Bei Ex-zertifizierten Messgeräten zusätzlich im Explosionsschutz • Bei Fragen kontaktieren Sie bitte Ihre zuständige Endress+Hauser ausgebildet. Serviceorganisation. Endress + Hauser...
  • Page 8 Sensor FMD71, FMD72 und Kabel Werkzeugliste Size 1, 2 20, 24, 26 mm Einsatz eines Sensors FMD71, FMD72 als Sensor LP oder Sensor HP Die Sensoren FMD71, FMD72 können sowohl als Sensor LP als auch Sensor HP eingesetzt werden, deshalb sollte die Bezeichnung LP oder HP mit der Inbetriebnahme auf das Typenschild aufgeklebt werden.
  • Page 9 Sensor FMD71, FMD72 und Kabel Verbindung zwischen Sensor LP und Sensor HP A Sensor LP (M20 / NPT1/2) 20 mm NPT1/2 24 mm Cable1 Cable2 Cable3 Cable4 B Sensor HP (M20 / NPT 1/2) 24 mm 24 mm 26 mm Cable5 Cable6 C Elektrischer Anschluss...
  • Page 10 Sensor FMD71, FMD72 und Kabel Verbindung zwischen Sensor HP und Transmitter Warnung! Verbindungskabel 100 ft; 30,48 m und 150 ft; 42,72 m nicht für die Verbindung zwischen Senor HP und Transmitter verwenden! A Sensor HP (M20 / NPT 1/2) 20 mm NPT1/2 24 mm Cable7...

This manual is also suitable for:

Deltabar fmd72

Table of Contents