Annex III
CABLE GLAND
Housing
certified II 2 GD
Ex db IIC / Ex tb IIC
A :
TYPE : Male Taper (conical) threaded joint: ¾'' NPT
Conform to NPT requirements of ANSI/ASME B1.20.1
A minimum of 5 threads provided on each part
MOUNTING RULE:
Thread cleaning with Loctite 7063 or equivalent product with
similar efficiency.
Cemented with Loctite 2700 (high-strength threadlocker) or
equivalent product with similar efficiency. This is mandatory to
meet an IP67.
Tightening torque (see Cable Gland instruction manual)
Check threads engagement (see Cable Gland instruction
manual)
B:
TYPE: Female Taper (conical) thread joints: ½" NPT or ¾" NPT
Conform to NPT requirements of ANSI/ASME B.1.20.1
A minimum of 5 threads provided on each part
TYPE: Female Cylindrical threaded joints: M20 x 1.5
Conform to ISO 965-1 and ISO 965-3 requirements
Minimum thread engaged: 5
Depth of engagement: ≥ 8 mm
MOUNTING RULE:
Thread cleaning with Loctite 7063 or equivalent product with
similar efficiency.
Cemented with Loctite 5400 (low strength thread sealant) or
equivalent product with similar efficiency. This is mandatory to
meet an IP67.
Tightening torque (see Cable Gland instruction manual)
Check threads engagement (see Cable Gland instruction
manual)
© 2020 Baker Hughes Company. All rights reserved.
Y237 ADAPTOR – MOUNTING RULES
Cable gland
certified II 2 GD
Ex db IIC / Ex tb IIC
PLUG
Housing
certified II 2 GD
Ex db IIC / Ex tb IIC
A :
TYPE : Male Taper (conical) threaded joint: ¾'' NPT
Conform to NPT requirements of ANSI/ASME B1.20.1
A minimum of 5 threads provided on each part
MOUNTING RULE:
Thread cleaning with Loctite 7063 or equivalent product with
similar efficiency.
Cemented with Loctite 2700 (high-strength threadlocker) or
equivalent product with similar efficiency. This is mandatory to
meet an IP67.
Tightening torque (see Cable Gland instruction manual)
Check threads engagement (see Cable Gland instruction
manual)
B:
TYPE: Female Taper (conical) thread joints: ½" NPT or ¾" NPT
Conform to NPT requirements of ANSI/ASME B.1.20.1
A minimum of 5 threads provided on each part
TYPE: Female Cylindrical threaded joints: M20 x 1.5
Conform to ISO 965-1 and ISO 965-3 requirements
Minimum thread engaged: 5
Depth of engagement: ≥ 8 mm
MOUNTING RULE:
Thread cleaning with Loctite 7063 or equivalent product with
similar efficiency.
Cemented with Loctite 2700 (high-strength threadlocker) or
equivalent product with similar efficiency. This is mandatory to
meet an IP67.
Tightening torque (see Cable Gland instruction manual)
Check threads engagement (see Cable Gland instruction
manual)
One plug only allowed or remove the Y237 (two plugs not
allowed)
Masoneilan 496 Series Position Transmitter ATEX Instruction Manual | 29
Plug
certified II 2 GD
Ex db IIC / Ex tb IIC