Annex III
CABLE GLAND
Housing
certified II 2 GD
Ex db IIC / Ex tb IIC
A :
TYPE : Male Taper (conical) threaded joint: ¾'' NPT
•
Conform to NPT requirements of ANSI/ASME B1.20.1
•
A minimum of 5 threads provided on each part
MOUNTING RULE:
•
Thread cleaning with Loctite 7063 or equivalent product with
similar efficiency.
•
Cemented with Loctite 2700 (high-strength threadlocker) or
equivalent product with similar efficiency. This is mandatory to
meet an IP67.
•
Tightening torque (see Cable Gland instruction manual)
•
Check threads engagement (see Cable Gland instruction
manual)
B:
TYPE: Female Taper (conical) thread joints: ½" NPT or ¾" NPT
•
Conform to NPT requirements of ANSI/ASME B.1.20.1
•
A minimum of 5 threads provided on each part
TYPE: Female Cylindrical threaded joints: M20 x 1.5
•
Conform to ISO 965-1 and ISO 965-3 requirements
•
Minimum thread engaged: 5
•
Depth of engagement: ≥ 8 mm
MOUNTING RULE:
•
Thread cleaning with Loctite 7063 or equivalent product with
similar efficiency.
•
Cemented with Loctite 5400 (low strength thread sealant) or
equivalent product with similar efficiency. This is mandatory to
meet an IP67.
•
Tightening torque (see Cable Gland instruction manual)
•
Check threads engagement (see Cable Gland instruction
manual)
© 2020 Baker Hughes Company. All rights reserved.
Y237 ADAPTOR – MOUNTING RULES
Cable gland
certified II 2 GD
Ex db IIC / Ex tb IIC
PLUG
Housing
certified II 2 GD
Ex db IIC / Ex tb IIC
A :
TYPE : Male Taper (conical) threaded joint: ¾'' NPT
•
Conform to NPT requirements of ANSI/ASME B1.20.1
•
A minimum of 5 threads provided on each part
MOUNTING RULE:
•
Thread cleaning with Loctite 7063 or equivalent product with
similar efficiency.
•
Cemented with Loctite 2700 (high-strength threadlocker) or
equivalent product with similar efficiency. This is mandatory to
meet an IP67.
•
Tightening torque (see Cable Gland instruction manual)
•
Check threads engagement (see Cable Gland instruction
manual)
B:
TYPE: Female Taper (conical) thread joints: ½" NPT or ¾" NPT
•
Conform to NPT requirements of ANSI/ASME B.1.20.1
•
A minimum of 5 threads provided on each part
TYPE: Female Cylindrical threaded joints: M20 x 1.5
•
Conform to ISO 965-1 and ISO 965-3 requirements
•
Minimum thread engaged: 5
•
Depth of engagement: ≥ 8 mm
MOUNTING RULE:
•
Thread cleaning with Loctite 7063 or equivalent product with
similar efficiency.
•
Cemented with Loctite 2700 (high-strength threadlocker) or
equivalent product with similar efficiency. This is mandatory to
meet an IP67.
•
Tightening torque (see Cable Gland instruction manual)
•
Check threads engagement (see Cable Gland instruction
manual)
•
One plug only allowed or remove the Y237 (two plugs not
allowed)
Masoneilan 496 Series Position Transmitter ATEX Instruction Manual | 29
Plug
certified II 2 GD
Ex db IIC / Ex tb IIC