6. Position Transmitter 496-8../. Electrical data
• Power supply:
Voltage Supply U (V)
Flameproof
Intrinsic Safety
• Lightning protection (in standard): 1500W 10/1000µs
• Output current 4-20mA (two wires)
• Zero range adjustment: ±0.5mA
• Span range adjustment: ±2.5mA
• Protected against polarity inversion
(Ω)
• Maximum load Zc
This means for 20mA:
Zc = 950 Ohm max with for an intrinsically safe loop
and
Zc = 1350 Ohm for Flameproof.
© 2020 Baker Hughes Company. All rights reserved.
Mini
Maxi
9.0V
36V
9.0V
28V
– 9.0
(
)
Supply Voltage
V
=
(
)
Imaxi
A
Supply
Voltage
(
)
V
Masoneilan 496 Series Position Transmitter ATEX Instruction Manual | 11
Zc