9.

Maintenance

– Before carrying out any work on the
device, power off the instrument or make
sure the local conditions are free of
potentially explosive atmosphere for safe
opening of the cover.
– These operations must be done in
conformance with EN 60079-17 and / or
national and local regulations applicable
for explosible atmospheres.
– Before power up or after doing any work
on the device always check the cover (12)
is fully screwed, O-ring (10) is free of any
damage and security screw (9) is well
locked.

10. Special Conditions of Work

Based on 2014/34/EU directive, a training session
must be followed by person usually recognized to
use apparatus in explosible atmospheres.
© 2020 Baker Hughes Company. All rights reserved.
• Check that no part of the 496 is damaged.
In the event of damage replace the defective
parts with genuine manufacturer's replacement
part.
• Pay particular attention to the following:
Check device, mechanical link and general aspect.
Check the cable gland and the electrical
connections.
Check the condition of the O-ring (10) of cover (12)
and O-ring (7) of the shaft (11).
Make sure that shaft (11) is not worn out or
damaged.
If the shaft (11) must be removed, make sure the
original circlips (8) is put back in place. Check that
neither the housing nor the shaft are damaged.
• Instruments installed in zones 20, 21 and 22 must
be cleaned to prevent any dust build up on the
walls. See instruction §11.1 b&c for safe cleaning.
This training session is not supported by Dresser
Produits Industriels S.A.S.
Masoneilan 496 Series Position Transmitter ATEX Instruction Manual | 21