Annex III
CABLE GLAND – ADAPTOR - REDUCER MOUNTING RULES
CABLE GLAND
496 Housing
certified II 2 GD
Ex db IIC / Ex tb IIC
TYPE :
Male Taper (conical) threaded joint: ¾" NPT
•
Conform to NPT requirements of ANSI/ASME B1.20.1
•
A minimum of 5 threads provided on each part
MOUNTING RULE:
•
Thread cleaning with Loctite 7063 or equivalent
product with similar efficiency.
•
Cemented with Loctite 5400 (low strength thread
sealant) or equivalent product with similar efficiency.
This is mandatory to meet an IP67.
•
Tightening torque (see Cable Gland instruction
manual)
•
Check threads engagement (see Cable
Gland instruction manual)
28
|
Baker Hughes
with similar efficiency.
•
Cemented with Loctite 5400 (low strength thread sealant)
or equivalent product with similar efficiency. This is
mandatory to meet an IP67.
•
Tightening torque (see Cable Gland instruction manual)
•
Check threads engagement (see Cable Gland instruction
manual)
Cable gland
certified II 2 GD
Ex db IIC / Ex tb IIC
ADAPTOR - REDUCER
Housing
certified II 2 GD
Ex db IIC / Ex tb IIC
A :
TYPE : Male Taper (conical) threaded joint: ¾" NPT
•
Conform to NPT requirements of ANSI/ASME B1.20.1
•
A minimum of 5 threads provided on each part
MOUNTING RULE:
•
Thread cleaning with Loctite 7063 or equivalent product with
similar efficiency.
•
Cemented with Loctite 2700 (high-strength threadlocker) or
equivalent product with similar efficiency. This is mandatory
to meet an IP67.
•
Tightening torque (see Adaptor-Reducer instruction manual)
•
Check threads engagement (see Adaptor-Reducer
instruction manual)
B:
TYPE:
Female Taper (conical) thread joints: ½" NPT or other NPT size
•
Conform to NPT requirements of ANSI/ASME B.1.20.1
•
A minimum of 5 threads provided on each part
TYPE:
Female Cylindrical threaded joints: M20 x 1.5 or other sizes
•
Conform to ISO 965-1 and ISO 965-3 requirements
•
Minimum thread engaged: 5
•
Depth of engagement: ≥ 8 mm
MOUNTING RULE:
•
Thread cleaning with Loctite 7063 or equivalent product with
similar efficiency.
•
Cemented with Loctite 5400 (low strength thread sealant) or
equivalent product with similar efficiency. This is mandatory
to meet an IP67.
•
Tightening torque (see Cable Gland instruction manual)
•
Check threads engagement (see Cable Gland instruction
manual)
© 2020 Baker Hughes Company. All rights reserved.
Adaptor-Reducer
certified II 2 GD
Ex db IIC / Ex tb IIC
B
A