Baker Hughes Masoneilan 496 Series Instruction Manual page 28

Position transmitter and limit switch, atex
Table of Contents

Advertisement

Annex III
CABLE GLAND – ADAPTOR - REDUCER MOUNTING RULES
CABLE GLAND
496 Housing
certified II 2 GD
Ex db IIC / Ex tb IIC
TYPE :
Male Taper (conical) threaded joint: ¾" NPT
Conform to NPT requirements of ANSI/ASME B1.20.1
A minimum of 5 threads provided on each part
MOUNTING RULE:
Thread cleaning with Loctite 7063 or equivalent
product with similar efficiency.
Cemented with Loctite 5400 (low strength thread
sealant) or equivalent product with similar efficiency.
This is mandatory to meet an IP67.
Tightening torque (see Cable Gland instruction
manual)
Check threads engagement (see Cable
Gland instruction manual)
28
|
Baker Hughes
with similar efficiency.
Cemented with Loctite 5400 (low strength thread sealant)
or equivalent product with similar efficiency. This is
mandatory to meet an IP67.
Tightening torque (see Cable Gland instruction manual)
Check threads engagement (see Cable Gland instruction
manual)
Cable gland
certified II 2 GD
Ex db IIC / Ex tb IIC
ADAPTOR - REDUCER
Housing
certified II 2 GD
Ex db IIC / Ex tb IIC
A :
TYPE : Male Taper (conical) threaded joint: ¾" NPT
Conform to NPT requirements of ANSI/ASME B1.20.1
A minimum of 5 threads provided on each part
MOUNTING RULE:
Thread cleaning with Loctite 7063 or equivalent product with
similar efficiency.
Cemented with Loctite 2700 (high-strength threadlocker) or
equivalent product with similar efficiency. This is mandatory
to meet an IP67.
Tightening torque (see Adaptor-Reducer instruction manual)
Check threads engagement (see Adaptor-Reducer
instruction manual)
B:
TYPE:
Female Taper (conical) thread joints: ½" NPT or other NPT size
Conform to NPT requirements of ANSI/ASME B.1.20.1
A minimum of 5 threads provided on each part
TYPE:
Female Cylindrical threaded joints: M20 x 1.5 or other sizes
Conform to ISO 965-1 and ISO 965-3 requirements
Minimum thread engaged: 5
Depth of engagement: ≥ 8 mm
MOUNTING RULE:
Thread cleaning with Loctite 7063 or equivalent product with
similar efficiency.
Cemented with Loctite 5400 (low strength thread sealant) or
equivalent product with similar efficiency. This is mandatory
to meet an IP67.
Tightening torque (see Cable Gland instruction manual)
Check threads engagement (see Cable Gland instruction
manual)
© 2020 Baker Hughes Company. All rights reserved.
Adaptor-Reducer
certified II 2 GD
Ex db IIC / Ex tb IIC
B
A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Masoneilan 496-857Masoneilan 496-858

Table of Contents