Installation Instructions; Technical Specifications - Pima DPS Series Installation Instructions Manual

Standard/pet immune wireless pir motion detectors
Table of Contents

Advertisement

Installation Instructions

The DPS (Standard) and the DPP (Pet immune) are wireless PIR (Passive Infra-Red) motion detectors in FastLink technology, designed
for the FORCE Series and VISION intruder alarm systems. Using the DPS/DPP in FORCE requires the installation of a wireless receiver.
The two detectors are based on digital processing, and utilize an advanced movement detection algorithm. The DPS and the DPP can be
used in apartments, private houses and also in offices.
The DPP is immune to animals weighing up to 25 kilograms.
The DPS and the DPP have an elegant design. When detecting a movement the detectors transmit an alarm signal to the control panel.
The detectors have a tamper switch that alerts when their enclosure is opened or removed from the wall.
The DPS and the DPP transmit a supervision event when replacing the battery and also every 15 min. The two detectors alert on low
battery condition. For enrollment information, see the alarm system's Installation guide.
Cautions: the DPS and the DPP are based on wireless (RF) transmissions. Any wireless
transmission can be subject to RF interference and, although unlikely, this interference may
cause the DPS and the DPP to not operate as intended. RF transmissions will be attenuated by
tinted glass, in wall isolation with metal foils, metal objects, etc.

Technical specifications

Frequency
Models
(MHz)
One-Way
433.92
DPS/DPP143 DPS/DPP243
868.95
DPS/DPP187 DPS/DPP287
Content of the product package
 DPS/DPP detector
Mounting considerations
 Surface or corner mount the detectors at a height between 1.8m and 2.5m.
 Allow the widest possible angle for the detector's coverage pattern.
 Mount the detector where an intruder will most likely cross through the coverage pattern; the DPS and DPS detection range is 10m
at 90 degrees.
 Do not mount the detectors outdoors or where direct sunlight can reach it.
 Do not mount the detectors where there are extreme levels of heat and light from heaters and air conditioners, hot and cold drafts,
lightning, and moving headlights.
 Do not mount the DPP detector where pets can climb into the upper field of view.
How to install the DPS/DPP
1.
Release the screw at the bottom of the detector and remove the cover.
2.
Break the matching knock outs on the backplate for surface or corner mount; see the figures above.
3.
Fix the backplate onto a flat surface.
4.
Place the battery. Observe polarity!
5.
Set the jumpers; see below.
6.
Reassemble the detector: tilt it upwards, push it against the top part of the backplate first and then push the rest of it; see the
Cover placing
figure above.
7.
Fasten the detector's screw.
8.
Enroll the detector (refer to the FORCE's Installation guide).
9.
Test the detector using the
The LED
All models
Color and state
Description
Green 1 blink
Battery OK, tamper closed.
Red 1 blink
Battery OK, tamper open.
Red 2 blinks
Low battery
 Sizes: 11 X 5.5 X 5.5 cm
 Weight: 110gr
Two-Way
 CE Compliance
 Temperature: -10 to +50 °C
 Screws, mounting tapes
Test and Diagnostics
menu.
Color and state
Green 2 blinks
Green 3 blinks
Red 3 blinks
 Battery: 1X CR123A, 3VDC, Lithium
 Battery Life: Up to Five Years (Typical Usage)
 Humidity (Max.): up to 93% R.H.,
 This guide
Two-way ("Walk test")
Reception (RSSI)
Good
Excellent
Poor
-2-
Non-condensing

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dpp seriesDpp143Dpp187Dpp243Dpp287Dps143 ... Show all

Table of Contents