F10

Installation

Mounting Angle

Incline the Head by 15° and mount the Head so that no regular reflection light affects the Sensor.
Use the provided Mounting Bracket to mount the Head.
F10-S30R: 100±10 mm
F10-S15R: 50±5 mm
F10-S05R: 33±1.5 mm
Note: Position the sensor perpendicular to the direction of motion of the target object.
Connection with Peripherals (F10-C50/C55 Only)
You can input the measurement trigger and output the measurement results via an RS-232C port. You can also back up the settings in an IBM
PC/AT or compatible. Refer to the Operation Manual for the Unit for details on communications commands.
1:1 Connection
Use F10 products for items marked with an asterisk.
F10-C50/C55
F10-S50R
F10-S30R
F10-S15R
F10-S05R
15°
Line direction
System configuration
*F10-VR2
RS-232C Cable
Simulation
Sensor direction
15° 15°
IBM PC/AT or
compatible
F10
Production
line direction