Standalone Power Connection; Ac/Dc Transformer Power Connection; Shelf Power Connection - ADTRAN NIU3 Installation And Maintenance Manual

Ds3 network interface unit

Advertisement

RETURN
SUPPLY
Figure 3. Standalone Power Connection
In this case the (red) power wire is connected to the
48V(+)/GND terminal and the (black) return wire to
the 48V(-) terminal. The green wire connects to the
Frame Ground terminal (see Figure 4).
CAUTION
Terminate grounds to an approved ground
location. Check metal to metal contact on all
ground connections, ensure ground circuit
continuity.
48V
200mA
GRN
RED
BLK
Figure 4. AC/DC Transformer Power
Connection
61212075L1-5C
TB1
48V(+)/GND
48V(-)
TB1
48V(+)/GND
48V(—)
Section 61212075L1-5, Issue 3
Standalone Ground Option
Optionally, frame ground is provided by a ground lug
on the standalone motherboard (J1). J1 and TB1 are
electrically connected. A ground wire portal on the
rear panel of the housing provides access for this
ground wire. J1 is a screw compression terminal
requiring a solid copper wire connection.
Shelf Power
The 12-slot shelf backplane has a dual power terminal
(TB1) with connections for -48V A, -48V RET A,
-48V B, and -48V RET B, plus a common Frame
Ground connection (see Figure 5). A backplane diode
arrangement allows both DC supplies to load-share
with one side picking up the entire load should the
other side fail.
A SUPPLY
A RETURN
B SUPPLY
B RETURN
FRAME
GROUND
Figure 5. Shelf Power Connection
Fuse
The -48 VDC is fused on each NIU3 card.
Options
Line Build Out
A 2-position DIP switch (SW2) on the NIU3 enables
signal attenuation towards both the network and the
customer. DIP switch option selection must be made
prior to inserting the NIU3 into the host circuit board.
If network equipment (e.g. ADM) is within 225 line
feet of the NIU3, enable LBO on SW2-1.
• SW2 Position 1 – ON, LBO toward network
enabled
• SW2 Position 1 – OFF, LBO toward network
disabled
TB1
-48V A
-48V RET A
-48V B
-48V RET B
3