Advertisement

Quick Links

DECLARATION OF CONFORMITY
Manufacturer:
CID Bio Science, Inc.
Felix Instruments – Applied Food Science
1554 NE 3
Camas, WA 98607
Declares that the CE-marked Product:
Product Models (s):
Complies With:
89/336/EEC Electromagnetic Compatibility
Directive
73/23/EEC Low Voltage Directive
Compliance Standards:
EN 55027
EN 50082-1
EN 60950
February 11, 2015
rd
Ave
Model F-750
RF Emissions Information
Technology Equipment
EMC Immunity Standard
Safety of Information
Technology Equipment
Including Electrical
Business Equipment
Leonard Felix
President

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F-750 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CID Bio-Science F-750

  • Page 1 CID Bio Science, Inc. Felix Instruments – Applied Food Science 1554 NE 3 Camas, WA 98607 Declares that the CE-marked Product: Product Models (s): Model F-750 Complies With: 89/336/EEC Electromagnetic Compatibility Directive 73/23/EEC Low Voltage Directive Compliance Standards: EN 55027...
  • Page 2: Table Of Contents

    Table of Contents Introduction ............1 F-750 Produce Quality Meter ......3 ................3 Features............... 4 Specifications ............5 Theory of Operation ..........6 Operating Instructions ..........8 Unpacking the F-750 ........... 8 Loading the Battery ..........8 ................9 Basic Operation ..........
  • Page 3 Step 3: Importing a Training Set and Reference Values into Model Builder......... 37 Step 4: Creating a Model ........41 Step 5: Saving a Model to F-750 ....... 53 Step 6: Validating the Model ......53 Additional Instructions: ........55 Exporting Data from Model Builder ....
  • Page 4 Frequently Asked Questions ......84 Warranty Information ........... 90 Appendix I: Mango Model Building Standard Operating Procedure (SOP) ........92 F-750 Production Test Check Sheet ....101 Warranty Registration Card ........ 104 This manual is updated for firmware version 1.2.6754...
  • Page 5: Introduction

    Judging fruit maturity by shape and color alone results in varying success. The F-750 delivers the stability, repeatability, and precision that is necessary...
  • Page 6 Analytica Chimica Acta, (150) 61-70. The principles of operation of the F-750 Produce Quality Meter allow it to predict ripeness indicators such as dry matter, soluble sugar content, degrees of brix, and many more.
  • Page 7: F-750 Produce Quality Meter

    F-750 Instruction Manual 5/10/2017 F-750 Produce Quality Meter 1554 NE 3 Ave, Camas, WA 98607, USA Phone: (360) 833-8835 sales@felixinstruments.com www.felixinstruments.com...
  • Page 8: Features

    F-750 Instruction Manual 5/10/2017 Features  Portable, lightweight and easy to operate. -One button operation for recording new measurements  Repeatable, precise, and non-destructive measurements. -Spectrometer standard deviation > 0.017%  True sunlight readable transflective display. -Contrast of this display actually increases under brighter sunlight ...
  • Page 9: Specifications

    F-750 Instruction Manual 5/10/2017 Specifications Spectrometer ZEISS MMS1 VIS-NIR Wavelength Range 310 – 1100 nm (+/- 10 nm) Spectral Sampling 3 nm Spectral Resolution 8-13 nm Accuracy Expected: +/- 0.5 Brix RMSEP (root mean square error of prediction) Battery Life...
  • Page 10: Theory Of Operation

    F-750 device and used to measure the parameters used to build the model. With a model loaded on the F-750 device, the user places a specimen on top of the scanner and presses the scan button to record a new measurement.
  • Page 11 A final intercept coefficient is added, resulting in the predicted value which the F-750 displays on screen, and saves to the instrument’s SD card along with other information such as GPS location, battery status, and temperature.
  • Page 12: Operating Instructions

    (one for the wall and a car charger), a white Teflon disc for standard or diagnostic scans, and a clip to attach the F-750 to a belt. In addition, an SD card is included along with a hand strap.
  • Page 13 F-750 Instruction Manual 5/10/2017 Warning: Do not drop batteries, this may cause them to crack and rupture. Top View: Front View: Scan Button Power Button 1554 NE 3 Ave, Camas, WA 98607, USA Phone: (360) 833-8835 sales@felixinstruments.com Directional Keys www.felixinstruments.com...
  • Page 14: Basic Operation

    The strap should be tightened so that the device has a snug and secure fit around the hand. To take a measurement, power on the F-750 Produce Quality Meter. The current model will be displayed. To change the model refer to the Select Model section of the manual.
  • Page 15 This will force the F-750 power to turn off. Then, the instrument can be restarted. When the F-750 device is powered on, it will make a single beeping sound if it is working smoothly. If not, the device will issue more than one beep. The number of beeps can be used to diagnose several errors that the instrument is able to detect during start-up.
  • Page 16: Navigating Menus

    F-750 Instruction Manual 5/10/2017 Navigating Menus Use the power button to turn on the F-750. After the instrument powers on, the display will show the current model loaded on the unit and the battery life at the top of the display. Instructions in the middle of the display...
  • Page 17: Menu Map

    F-750 Instruction Manual 5/10/2017 Menu Map 1554 NE 3 Ave, Camas, WA 98607, USA Phone: (360) 833-8835 sales@felixinstruments.com www.felixinstruments.com...
  • Page 18: Select Model

    F-750 Instruction Manual 5/10/2017 Select Model The device will come pre-loaded with demo models, use the up/down arrows to highlight the desired selection. To make modifications to the model, press the right arrow when the model is highlighted to get to the model sub- menu.
  • Page 19: Browse Measurements

    F-750 Instruction Manual 5/10/2017 arrows and then pressing the left arrow to return to the Main Menu. Scans to Average: This option allows the user to select the number of scans (measurements) that are averaged together before a value is shown on the display.
  • Page 20: Setup Instrument

    F-750 Instruction Manual 5/10/2017 highlighted, press the right arrow to access the measurement data. Each measurement has different parameters saved, depending on the model used when taking the measurement. For example, a mango model may include values for dry matter, color, and chlorophyll.
  • Page 21 F-750 Instruction Manual 5/10/2017 be assigned to each box and the sample number would be assigned to each apple in a box. The lot and sample numbers are included in the filename of a measurement and increment with each scan.
  • Page 22 Date & Time: The Date & Time option allows the timestamp on the F-750 to be adjusted. Training Sets: Creating a training set is the first step in creating a model. This menu is used when collecting spectra to use in the training set.
  • Page 23 F-750 Instruction Manual 5/10/2017 -Create New Training Set: First, enter the name to use for this new training set. Next, enter the number of specimens that will be used to build this model. The minimum number of specimens required is 10 and the maximum number allowed is 5,000.
  • Page 24 Notification Sounds: This option enables an amplified speaker and beeper to audibly verify when a scan has completed. Language: At this time the F-750 supports English only, but the firmware update installs a language pack that can allow and recognize different language characters.
  • Page 25 F-750 Instruction Manual 5/10/2017 -Lamp state: This option is used to turn the lamp on or lamp off. Press the down or up arrows to turn the lamp off or on. The shutter state works similar to the lamp state.
  • Page 26: Warnings

     Instrument will become warm with use, due to the lamp turning on.  Do not drop F-750 batteries on hard surface, such as cement floor.  Do not leave the lamp on for more than 30 seconds.
  • Page 27: F-750 Data

    SD card. In order to view the files on a computer, the F-750 Data Viewer software should be installed. This software can be found on the Felix Instruments webpage located at: http://felixinstruments.com/support/f-750-...
  • Page 28 F-750 Instruction Manual 5/10/2017 Once a file or files have been opened in DataViewer, data can be exported to be viewed. The File>Export menu gives four different options to export: Measurements, Measurements & Details, Raw Spectra, and Interpolated Spectra. To export the predicted values, select Measurements and choose to open the newly created .csv file.
  • Page 29: Wifi Sd Card Instructions

    F-750 Instruction Manual 5/10/2017 After exporting, the .csv file can be opened as a spreadsheet. This .csv can be used in other software programs. Data such as model results, which contains GPS coordinates, dry matter, TSS, battery life, and raw readings can be viewed in the .csv file.
  • Page 30 F-750 Instruction Manual 5/10/2017 Optional Settings The Wi-Fi card can be enabled in “internet pass thru mode”, outlined in the following documentation provided within the FlashAirTool software: • Go to Network Settings on the main menu Check Internet pass thru mode This function is available for FlashAir™...
  • Page 31 F-750 Instruction Manual 5/10/2017 services, as there is no need to change the Wi-Fi device network settings on your smartphone. * CAUTION: If you want to connect to the internet without using the internet pass thru mode, the wireless LAN setting connection on...
  • Page 32 F-750 Instruction Manual 5/10/2017 o In your browser, enter http://flashair to view or stream your files (it has been verified it works on Chrome browser) For more information on the Toshiba FlashAir™ W-03 Wireless SD Memory Card, contact the application vendor https://www.toshiba.co.jp/p-...
  • Page 33: Instructions For Creating A Model

    Collecting Reference Values Step 3: Importing a Training Set and Reference Values into Model Builder Step 4: Creating a Model Step 5: Saving a Model to F-750 Step 6: Validating the Model Additional Instructions: • Merging Training Sets in Model Builder •...
  • Page 34 F-750 will be used on fruit which does not always remain a constant temperature, a training set will need to be created to accommodate for this potential temperature range.
  • Page 35 F-750 Instruction Manual 5/10/2017 2. Label each piece of fruit with a specimen number. 3. Mark the area to be scanned on each fruit. Two sides of the same fruit are often scanned depending on the variability of the fruit (sun side and shade side).
  • Page 36 (generally about one hour), it is now time to begin taking measurements for the training set. 7. Turn on the F-750 and navigate to the Setup Menu > Training Sets > Create New Training Set. 8. Enter a name to use for the new training set.
  • Page 37 F-750 Instruction Manual 5/10/2017 pre-labeled specimen. Be careful not to remove too many specimens at a time from the temperature controlled environment, as you want the set temperature to remain constant across specimens. 11. Place the first specimen on the lens, and with...
  • Page 38 Always scan the same area of the fruit. 16. If you had turned the F-750 off while waiting for the specimen to reach their next temperature, navigate to the Setup menu >...
  • Page 39 Maximum. 20. Wait for the specimen to reach their next temperature, then continue to next step. 21. See step 16 if you have turned the F-750 off while waiting for the specimens to reach the next temperature.
  • Page 40: Step 2: Collecting Reference Values

    F-750 Instruction Manual 5/10/2017 Step 2: Collecting Reference Values To collect Reference Values, the same fruit specimens used in training set creation will be measured. The Reference Values are those values determined by your reference method (i.e. a destructive measurement of TSS or DM).
  • Page 41: Step 3: Importing A Training Set And Reference Values Into Model Builder

    It is important to save your Model Builder file so that you can return to it at a later time and add additional data if desired. 1. Open the F-750 Model Builder Software program. If you have not already downloaded this program onto your computer, please download at: https://felixinstruments.com/support/F-...
  • Page 42 F-750 Instruction Manual 5/10/2017 2. Remove the SD card from the F-750 and insert it into your computer. 3. First, we will import our training set. Which is the set of scans recorded on the F-750 as .f750ts file extensions. In Model Builder, navigate to the Import button on the right side of the software window.
  • Page 43 F-750 Instruction Manual 5/10/2017 7. Model Builder will automatically populate the training set and the spectra should now be displayed on screen. Specimen number, Spectra Name (Min, Mid, Max temp), and the pixel values can be found under the Training Set tab at the bottom of the screen.
  • Page 44 10. Next, we will import our Reference Values, which are the values independently gathered and not by using the F-750. For example, for Brix one may use a reference method of reading Brix values on a refractometer, or titratable acids on a titrator.
  • Page 45: Step 4: Creating A Model

    F-750 Instruction Manual 5/10/2017 programs as a column with no header. Specimen numbers are auto-populated starting at 1. 11. Be sure that all specimens included in the training set also have corresponding and matching Reference Values. To change the column headers, double-click to rename them (e.g.
  • Page 46 F-750 Instruction Manual 5/10/2017 To manually select a spectral region, enter the desired range under the Model Spectra tab located at the bottom of the window. b. Seeing a neatly layered rainbow effect with the colors (green-orange-red) in the selected range is optimal and indicates agreement of spectra and known results.
  • Page 47 F-750 Instruction Manual 5/10/2017 regression used by the F-750. The various graphs in the drop down menu allow for analysis of different aspects of the multivariate data, including principle components (explained variance), root mean square error (RMSE), model linearity, prediction error, regression coefficients, error/deviation ratio, and scores plot.
  • Page 48 F-750 Instruction Manual 5/10/2017 After the model is successfully built, the F-750 Model Builder Software will show the Model Performance Analysis tab. Click on the tab and the first screen shown is the explained variance. The explained variance graph is useful for understanding how well the variation in the known value is spanned by the regression model.
  • Page 49 RMSECV is the average error and is considered to be the error within the first standard deviation or 68% of all readings. The F-750 Model Builder Software determines the optimum number of principle components by looking for a minimum decrease of at least 5%. In the example below, 8 principle components have an RMSECV of 0.61, a...
  • Page 50 F-750 Instruction Manual 5/10/2017 The Prediction Error graph displays the reference value vs. the predicted value for both the complete regression and the cross validation. This graph is useful for determining outliers or specimen that do not fit well within the regression.
  • Page 51 F-750 Instruction Manual 5/10/2017 Navigate to the Scores Plot graph, which is used to identify clusters or groupings in data. In the example below, the red table grapes form a small cluster below the green grapes. The figure below has a red and green circle indicating the red and green grape clusters.
  • Page 52 F-750 Instruction Manual 5/10/2017 spread of data at a particular wavelength in comparison to the rest of the spectra. Wavelengths with high prediction power and a large range are weighted more heavily than those where one or both of the parameters are small.
  • Page 53 F-750 Instruction Manual 5/10/2017 on the “wavelength influence” regression coefficient multiplied by the degree of deviation from the established range. Thus, a sample scan that fits perfectly within the training set range will yield a model fit number equal to 0, while subsequent deviations will scale according to the wavelength influence and magnitude of deviation.
  • Page 54 F-750 Instruction Manual 5/10/2017 Optimizing the Grape Demo Model: Now we will go back and optimize the grape demo model. To begin, navigate back to the Scores Plot and hover over the Potential Outlier scan in the lower right quadrant. We can see that this is specimen number 239 with the spectra name of r39.
  • Page 55 F-750 Instruction Manual 5/10/2017 change, it can be concluded that specimen 239 is not an outlier and should be included in the training set. Go back to the training set, include #239 and build the model again. Next, look at the Prediction Error graph. Here, you can see that specimen 260 is poorly predicted by the model.
  • Page 56 F-750 Instruction Manual 5/10/2017 Additional Information from Scores Plot: The following shows the effect of temperature on the O-H peak (spectra) of a cherry. The upper curve in pink is room temperature and the lower blue curve is cold storage (min temp).
  • Page 57: Step 5: Saving A Model To F-750

    2. To save the model to an F-750 SD card, locate the SD card and save your new model (verify that your ‘save as type’ corresponds to your F-750 firmware version) in the Models folder.
  • Page 58 F-750 Instruction Manual 5/10/2017 3. Press the right arrow and then select Set As Current Model. 4. Place a specimen on top of the F-750 and press the scan button. 5. Scan several specimens and measure to gauge the variance of the model.
  • Page 59: Additional Instructions

    F-750 Instruction Manual 5/10/2017 The procedure for Brix is shorter, with day 1 consisting of the training set, reference values and creating the model. Day 2 consists of on device prediction and reference values. Notes: • The model’s margin of error is based on the...
  • Page 60: Merging Training Sets In Model Builder

    F-750 Instruction Manual 5/10/2017 Clipboard’. Paste this data into Excel or other third party analysis software for easy manipulation. Merging Training Sets in Model Builder Data can be added to an existing Model Builder file at any time to increase the accuracy of the model or increase the range of values.
  • Page 61 F-750 Instruction Manual 5/10/2017 whether the training set is from the same population. See the following examples A and B: a. If the training set #2 is of the same specimens, click “No”. Example training set #1 has only the minimum...
  • Page 62: Alternate Method For Training Set Creation: Manual Data Collection And Entry

    This alternative method gives more flexibility in importing data, but extra care must be taken in data organization, and data entry into the F-750 Model Builder Software. First we will collect the data using the manual method: 1554 NE 3...
  • Page 63 F-750 Instruction Manual 5/10/2017 1. Follow steps from Part 1: Creating a Training Set, #1-6. 2. Turn on the F-750 and navigate to the Select Model menu. Select any model. For the purposes of this method of data collection, the model used does not make a difference in the spectra collected.
  • Page 64 Next, collect your Reference Values 1. Follow steps from part 2: Collecting Reference Values (See Step 2 above). Next, extract the F-750 specimen spectra data using Data Viewer software and import into Model Builder. 1. Open the Data Viewer software program. This...
  • Page 65 F-750 Instruction Manual 5/10/2017 2. Remove the SD card from the F-750 and insert it into your computer. Locate the specimen measurements have taken for the training set. 3. Choose files to open in Data Viewer. 4. Go to the File>Export>Interpolated Spectra. Click on the menu and select 2 Derivative.
  • Page 66 285-1200 nm). Then paste into ModelBuilder under the training set tab. 9. Open the F-750 Model Builder Software program. Note that under the training set tab, the spectra begins at the same pixel; 285 nm. This is where we will paste our data.
  • Page 67 F-750 Instruction Manual 5/10/2017 13. Next, we will import our Reference Values. If they are in CSV format, navigate to the Import button on the right side of the Model Builder screen. If the reference values are not in CSV format, they can be manually entered or copied and pasted from Excel.
  • Page 68: Building A Model To Measure Two Traits

    F-750 Instruction Manual 5/10/2017 Building a Model to Measure Two Traits Building a model to measure more than one trait (such as dry matter, brix, or chlorophyll), is often a very useful and timesaving method. To do this, we will slightly alter our reference collection method to accommodate the collection of more than one parameter.
  • Page 69 When building a training set with two scans per piece of fruit (left cheek and right cheek), care must be taken as to how the data is arranged in F-750 Model Builder Software. When put into model builder with a single training set,...
  • Page 70: Using The Small Fruit Adaptor Accessories

    For very small fruit there is a limited amount of light on the fruit and the reflector cone can change the angle and provide more light. For example, a blueberry looks brighter when placed on the F-750 with proper reflector cone, and looks very dark without it. 1554 NE 3...
  • Page 71 F-750 Instruction Manual 5/10/2017 Selecting a Small Fruit Adaptor Accessory: It is important to be consistent when taking scans for training sets and predictions: the accessory should be used for all samples or for none. If the fruit does not fit in...
  • Page 72 F-750 Instruction Manual 5/10/2017 To use the reflector cones, one quick changeover must first be made to the F-750 by installing the small fruit adaptor (black ring with central circle and 3 spokes). Using a #1 Phillips head screwdriver, swap this adaptor with the plain one currently on the F-750.
  • Page 73: Cleaning And Maintenance

    F-750 Instruction Manual 5/10/2017 Cleaning and Maintenance Keep the lens of the F-750 clean and protected from dirt and scratches. If the lens is dirty, unscrew the cover plate and gently wipe the lens in a smooth straight motion with rubbing alcohol and a clean nonabrasive cloth.
  • Page 74: Firmware Update Procedure

    F-750 Instruction Manual 5/10/2017 Firmware Update Procedure The firmware of the F-750 is updated by connecting the instrument to a computer using a USB cable and running the Firmware Update tool. The firmware update tool includes step-by-step instructions for updating the firmware.
  • Page 75: Supporting Science

    F-750 Instruction Manual 5/10/2017 Supporting Science Fish Fat and Moisture Content Downey, G. (1996). Non-invasive and non-destructive percutaneous analysis of farmed salmon flesh by near infra-red spectroscopy. Food Chem. 55:305–311. • NIR interactance range 700-1100 nm • 6 sites on dorsal and ventral side of each fish (measurement through skin and scales).
  • Page 76: Wine Grape Anthocyanin Content

    F-750 Instruction Manual 5/10/2017 and varied with measurement locations on the fish body. Wold, J. P. and Isaksoon, T. (1997), Non-Destructive Determination of Fat and Moisture in Whole Atlantic Salmon by Near-Infrared Diffuse Spectroscopy. Journal of Food Science, 62: 734–736.
  • Page 77: Mango Model Optimal Wavelengths

    F-750 Instruction Manual 5/10/2017 • Demonstrates extraction of these phenolic pigments from grape skins into the wine during fermentation. Mango Model Optimal Wavelengths Subedi, P., Walsh, K., Owens, G. (2007) Prediction of mango eating quality at harvest using short-wave near infrared spectrometry.
  • Page 78: Kiwifruit

    F-750 Instruction Manual 5/10/2017 Kiwifruit McGlone, V.A. (1998). Firmness, dry-matter and soluble- solids assessment of postharvest kiwifruit by NIR spectroscopy. Postharvest biology and technology (0925- 5214), 13 (2), 131. • NIR interactance range for Dry Matter and TSS 800-1100 nm.
  • Page 79: Publications

    F-750 Instruction Manual 5/10/2017 Publications Cozzolino, D., Parker, M., Dambergs, R. G., Herderich, M. and Gishen, M. (2006), Chemometrics and visible-near infrared spectroscopic monitoring wine fermentation in a pilot scale. Biotechnol. Bioeng., 95: 1101–1107. Downey, G. (1996). Non-invasive and non-destructive percutanous analysis of farmed salmon flesh by near infra- red spectroscopy.
  • Page 80 F-750 Instruction Manual 5/10/2017 Savitzky, Golay, (1964) Smoothing Differentiation of Data by Simplified Least Squares Procedures. Analytical Chemistry, 36(8) 1627–1639. Sjostrom, M., Wold, S. (1983) A multivariate calibration problem in analytical chemistry solved by partial least- square models in latent variables. Analytica Chimica Acta, (150) 61-70.
  • Page 81 F-750 Instruction Manual 5/10/2017 Subedi, P., Walsh, K., Owens, G. (2007) Prediction of mango eating quality at harvest using short-wave near infrared spectrometry. Postharvest Biology Technology, 43: 326–334. Subedi, P., Walsh, K., Purdy, P. (2010) Determination of Optimum Maturity Stages of Mangoes Using Fruit Spectral Signatures, China Int Mango Conf 1-12.
  • Page 82: F-750 Vocabulary Definitions

    F-750 Instruction Manual 5/10/2017 F-750 Vocabulary Definitions Aroma: Comes from volatiles given off by the fruit as they are detected by olfactory receptors when fruit is chewed and swallowed. Dry Matter (DM): The ratio of the water content to the dry weight of the fruit.
  • Page 83 F-750 Instruction Manual 5/10/2017 Theory of Operation section page 6). Model Builder File: The type of file used by the F-750 Model Builder Software which includes the Training Set, Reference Values and ranges of spectra to build the model used by the device.
  • Page 84 F-750 Instruction Manual 5/10/2017 make predictions. Regression coefficients are a series of weighted values generated by PLS. When these are applied to a scan of an unknown sample, a prediction of concentration is made. These values are the core of the mathematical model.
  • Page 85 F-750 Instruction Manual 5/10/2017 Root Mean Squared Error Prediction (RMSEP): A measure of true prediction, measured on real fruit and compared to reference values of an independent data set. Savitzky–Golay Coefficients: A mathematical tool used to smooth spectra and to generate first or second derivatives.
  • Page 86: Technical Support

    F-750 Instruction Manual 5/10/2017 Technical Support If you have a question about the F-750, first look in the F- 750 Instruction Manual. There is also online support available F-750 http://felixinstruments.com/support. If you cannot find the answer, you can contact a Technical Support Representative located in your country.
  • Page 87: Customer Service

    F-750 Instruction Manual 5/10/2017 Customer Service Customer Service Representatives answer questions about specifications and pricing. Customers sometimes find that they need Felix Instruments to upgrade, recalibrate or repair their system. In order for Felix Instruments to offer these services, the customer must first contact us and obtain a Return Merchandise Authorization (RMA) number.
  • Page 88: Frequently Asked Questions

    2. How do I recharge the batteries of the F-750? To recharge the batteries, peel off the rubber bumper from the F-750. Then twist to remove the battery compartment cap (located on the bottom of the F-750).
  • Page 89 F-750 Instruction Manual 5/10/2017 4. What do I do if the F-750 SD card becomes corrupted? If your F-750 keeps indicating that it is "checking SD card" or is creating 0 byte length files, this is likely an indicator of a corrupt SD card. Remove the SD card and insert it into a computer.
  • Page 90 F-750 Instruction Manual 5/10/2017 the option to press the left arrow to abort or the right arrow to continue taking continuous scans. 6. I am having trouble updating the firmware on my device, what can I do? If you experience any issues with the firmware updating process, “Bootloader Assist”...
  • Page 91 F-750 Instruction Manual 5/10/2017 The F750 and F-750 Model Builder Software were designed to be compatible with the original NIRvana. As such, the coefficients are identical to unscrambler V8 and below. 10. What is Model Fit? The Model Fit Parameter is a numerical indicator of usefulness of the current model.
  • Page 92 FAQ’s and I still don’t know what to do. What do I do now? If you have a question about the F-750, first look in the F-750 Instruction Manual. There is also online support available for the F-750 at http://felixinstruments.com/support.
  • Page 93 F-750 Instruction Manual 5/10/2017 When prompted to choose the download you want: Select "VSU_4/vcredist_x86.exe" Press Next, Select Uninstall Repeat the above steps, then select to install. Once the setup is complete, open Model Builder and try to rebuild your old model again.
  • Page 94: Warranty Information

    F-750 Instruction Manual 5/10/2017 Warranty Information Seller's Warranty and Liability: Felix Instruments- Applied Food Science warrants new equipment of its own manufacturing against defective workmanship and materials for a period of one year from date of sale. The results of ordinary...
  • Page 95 F-750 Instruction Manual 5/10/2017 implied warranties of merchantability and fitness for a particular purpose), not expressly set forth herein. All instrument repairs or replacement covered under warranty require a Returned Material Authorization (RMA) number. Please contact Felix Instruments technical support department at support@felixinstruments.com to obtain an RMA...
  • Page 96: Appendix I: Mango Model Building Standard Operating Procedure (Sop)

    Appendix I: Mango Model Building Standard Operating Procedure (SOP) The following procedure outlines the process of creating a model on the F-750 device for dry matter and TSS (brix) with mangos. This SOP is also available at https://felixinstruments.com/support/F-750/ I. Getting prepared for model building Equipment needed: ...
  • Page 97 II. Preparing the F-750 Equipment needed:  F-750 1. Turn on the F-750 and navigate to the Setup Menu > Training Sets > Create New Training Set. 2. Enter a name to use for the new training set using the up and down arrows to select...
  • Page 98 1. Place the first specimen on the fruit adaptor of the F-750 and use a permanent marker to mark the area to be scanned. 2. On the F-750 with Specimen 1 highlighted on the list, press the right arrow to collect the training spectra. The instrument will indicate “Processing”.
  • Page 99 6. After specimens have reached the desire Mid temperature, the next set of temperature data is ready to be collected. 7. If you have turned off the F-750 while waiting for the specimens to reach their next temperature, navigate to the Setup Menu > Training Sets >...
  • Page 100  Food dehydrator(s) 1. Remove the fruit skin from the area which was marked and scanned with the F-750 with a sharp knife being careful to fully remove the skin ONLY, taking care to remove as little tissue under the skin as possible.
  • Page 101 F-750 Instruction Manual 5/10/2017 4. Trim the mango core on the seed side, so the total height of the cylinder is 2cm. 5. Weigh the sample in a microbalance as soon as is possible and record the weight to the nearest .001 grams.
  • Page 102 2. Remove the fruit skin from the area which was marked and scanned with the F-750 with a sharp knife being careful to fully remove the skin ONLY, taking care to remove as little tissue under the skin as possible.
  • Page 103 F-750 Instruction Manual 5/10/2017 12. It is useful to occasionally check the zero of the refractometer with DI water. 1554 NE 3 Ave, Camas, WA 98607, USA Phone: (360) 833-8835 sales@felixinstruments.com www.felixinstruments.com...
  • Page 104 F-750 Instruction Manual 5/10/2017 1554 NE 3 Ave, Camas, WA 98607, USA Phone: (360) 833-8835 sales@felixinstruments.com www.felixinstruments.com...
  • Page 105: F-750 Production Test Check Sheet

    F-750 Instruction Manual 5/10/2017 F-750 Production Test Check Sheet Date: ___________________ Technician Initials: ___________________ Serial #: ___________________ Spectrometer #: ___________________ Firmware Version: ___________________ Spectrometer Pixel Coefficients Spectrometer DAC Offset: Reference Voltage: 1554 NE 3 Ave, Camas, WA 98607, USA Phone: (360) 833-8835 sales@felixinstruments.com...
  • Page 106 F-750 Instruction Manual 5/10/2017 1554 NE 3 Ave, Camas, WA 98607, USA Phone: (360) 833-8835 sales@felixinstruments.com www.felixinstruments.com...
  • Page 107 F-750 Instruction Manual 5/10/2017 1554 NE 3 Ave, Camas, WA 98607, USA Phone: (360) 833-8835 sales@felixinstruments.com www.felixinstruments.com...
  • Page 108: Warranty Registration Card

    F-750 Instruction Manual 5/10/2017 Warranty Registration Card 1554 NE 3 Ave, Camas, WA 98607, USA Phone: (360) 833-8835 Fax: (360) 833-1914 e-mail: sales@felixinstruments.com Web: www.felixinstruments.com PRODUCT REGISTRATION CARD Please complete and return this form to Felix Instruments within 30 days to validate your Warranty on Parts &...

Table of Contents