Data Logger Installation; Eq Lte Current And Volt Data Logger - Quincy EQ LTE 2014900479 Technical Manual

Table of Contents

Advertisement

Fast flash
Fast flash
Troubleshooting: Check installation
Time out:
5 minutes
LED diagnostics will remain ON for 5
minutes after the key is pressed

4.2.8 Data logger installation

Prior to installation make sure that data
loggers are configured using the Audit Wizard
feature at quincy.scadar.net.
Print and retain the audit configuration check
list before attending the audit location!
Download the audit configuration from
quincy.scadar.net to your EQ LTE™ base
station
Transfer the audit configuration from your EQ
LTE™ base station to each EQ LTE™ data
logger
Ensure that each data logger is installed to the
assigned audit location (e.g. air compressor
brand, model and or serial number or pressure
point)
4.2.9 EQ LTE™ current & volt data logger
4.2.9.1 Technical data:
Identification:
EQ LTE™ Logger, current & volts
Part number:
Product family:
Definition:
Function:
Data logger:
A / D resolution:
Battery life:
Bluetooth (slave):
Bluetooth range:
Configured,
sensing
current data,
sensing
voltage data
Current and
volt logger
only...
Configured,
not sensing
valid data
2014900356
EQ LTE™
EQ LTE™ current & volts
data logger
Precision data logging
16 bit
2 calendar years or more
(est.)
2.1 + EDR (enhanced data
rate)
10 meters (33 feet)
The effective range varies due to propagation
conditions, material coverage, production
Operating temp:
Power / batteries:
Four AA lithium primary cells,
Real time clock:
Maximum deviation:
Sample capacity:
More than 1.4 million samples
(16 days continuous logging)
Sample frequency:
Software:
Current sensor:
AC voltage:
AC current:
Accuracy:
Max nondestructive
current:
Ambient temperature
influence on accuracy:
+18°C and from 28°C to 50°C
Rise / fall time:
Burden resistance:
Operating temp:
Storage temp:
Safety rating:
Useable frequency:
216mm (8.5") x 111mm (4.4")
Dimensions:
Jaw capacity:
Weight
Conformity:
Drop test:
Mech and shock test:
Regulatory mark:
Volt measurement and test lead set:
Measuring device:
CAT IV 600V, CAT III 1000 V,
Test lead set:
shrouded, standard diameter
Right angle connector on one
end and straight connector on
CAT IV 600V, CAT III 1000 V,
Conformity:
Regulatory mark
sample variations, antenna configurations and
battery conditions
0°C ~ +55°C (+32°F ~
+131°F)
Li/SOCI2, 3.6V, 2700mAh
Precision real time clock
(temp compensated crystal)
0.4s / day
1 second (fixed resolution)
Pre-programmed application
software
Range: 100 V to 700 V
Accuracy: 1%
Range: 10 Amp ~ 800Amp
1%
2000 A
<0.1% per 1°C for
temperatures from -10°C to
< 400ms
≤1 ohm
-10°C ~ +50°C (+14°F ~
+122°F)
-40°C to +70°C (-40°F to
+160°F)
CAT III 600V
10Hz – 100 kHz
x 45mm (1.8")
52mm (2.05 inch)
0.65kg (1.4lb)
IEC61010-031: 2008
IEC61010-1: 2010
IEC 68-2-32 @ 1 meter
IEC 68-2-27 @ 100G
CE, UL
Alligator clip set (2)
Red & black pair of small,
insulated, nickel plate jaws
Blunt tip grabs round screw
heads up to 9.5mm
10A rating
Red & black with safety
banana plugs
the other
Reinforced strain relief
1.5metre silicone-insulated
wire resists heat & cold
10A rating
EN 61010-1-032
73/23/EEC, Low voltage
(amended 93/68/EEC)
CE, UL
Page 13