Equipment Technical Manual
Base Station

Advertisement

Table of Contents
loading

Summary of Contents for Quincy EQ LTE 2014900479

  • Page 1 Equipment Technical Manual Base Station...
  • Page 2 Complete Kit & Additional Loggers EQ LTE Recommended Kit 2014900479 2014900356 EQ LTE, Logger, Current & Volts (CS800) (10-800Amps) 2014900357 EQ LTE, Logger, pressure, 0-16 BAR (0-232 psi) 2014900359 EQ LTE, Base Station & Power Supply 2014900360 Logger carry bag, Blue EQ LTE, Base station &...
  • Page 3 Additional Loggers EQ LTE, Logger, Flow - complete case kit 2014900361 2014900361 Kit Contains Logger Case EQ LTE, Logger, flow - logger assembly EQ LTE, Sensor, flow EQ LTE, Power Supply (100 - 240vAC input / DC output power supply c/w plug assortment) EQ LTE, Logger, Temperature - complete case kit 2014900365 2014900365 Kit Contains...
  • Page 4: Table Of Contents

    Contents: Safety Warning Safety Warning Installation Operation Maintenance Batteries General description Version revision EQ LTE equipment EQ LTE base station 4.1.1 Physical 4.1.2 Preparing for first use 4.1.3 General operation 4.1.4 Technical data 4.1.5 Power supply 4.1.6 Keypad 4.1.7 Graphical user interface 4.1.8 Menu navigation 4.1.9...
  • Page 5 Trademarks: EQ LTE™, the EQ LTE logo are trademarks or registered trademarks of Quincy Compressor. All other trademarks are the property of their respective owners. Copyright © Quincy Compressor. All rights reserved. Page 2...
  • Page 6 IF YOU DO NOT AGREE TO ALL OF THE TERMS OF THIS AGREEMENT, RETURN THE PRODUCT TO THE PLACE OF PURCHASE. Quincy Compressor and its suppliers grant to Customer ("Customer") a nonexclusive and non- transferable single user license to use the Quincy Compressor software ("Software") in object code form solely on a single EQ LTE...
  • Page 7: Safety Warning

    Section 1: Safety Warning: When installing, commissioning, operating or carrying out service or maintenance on the Section 1.1: Safety warning device, personnel must use relevant safe working practice and observe all relevant local This ‘EQ LTE product wide’ safety warning health and safety requirements and should be read and understood.
  • Page 8: Operation

    check the circuit. Be aware that other nearby The device’s batteries are monitored, circuits can still be powered. replacing the batteries during operation is not necessary. Do not open access panels or approach electrical components while voltage is applied Do not operate the device in high humidity unless measurements are impossible environments or with wet hands otherwise.
  • Page 9: General Description

    When replacement batteries are required, turn, the base station transfers this data to our replace all four batteries inside the device quincy.scadar.net cloud computing platform. battery compartment with suitable new ones. Here, it is encrypted and stored so that is can...
  • Page 10: Version Revision

    3.0 Version revisions 4.1.2 Preparing for first use Use the base station graphical user interface and EQ LTE™ base station operating Each EQ LTE™ base station is supplied with a procedures to maintain software in both the power supply and a variety of ‘domestic’ power EQ LTE™...
  • Page 11: General Operation

    EQ LTE™ update as described in this manual. base station to the quincy.scadar.net cloud computing environment. Your EQ LTE™ base station is ready for use! Only one EQ LTE™ base station is required to Notes: EQ LTE™...
  • Page 12: Keypad

    4.1.7 Graphical user interface The graphical user interface of the Base to cloud: Used to EQ LTE™ base station is designed to transfer data files from complement the quincy.scadar.net base station to the cloud computing environment. quincy.scadar.net cloud computing environment...
  • Page 13: Eq Lte Data Loggers

    Settings/Download logger update: Used to download logger software updates from quincy.scadar.net. to logger(s) using Bluetooth Settings/Update loggers: Used to initiate update of logger(s) via Bluetooth Note: Case contents vary. Each case features: • Settings/Update loggers: Durable polypropylene material Screen prompt indicating •...
  • Page 14: Preparing For First Use

    using internal lithium batteries. Some EQ LTE™ data loggers also feature an external power supply input. This is used to Side elevation power the data logger sensor. Note: The use of an external power supply unit does not eliminate the use of or need for the data logger’s internal lithium batteries! Side elevation...
  • Page 15: Bluetooth Key And Led

    Paired screwdriver to unscrew and access the battery Time out: 1 minute compartment by removing the battery compartment door. If a data logger has not found a discoverable base station within one When required to do so, change all batteries! minute, the search will end.
  • Page 16: Data Logger Installation

    -10°C ~ +50°C (+14°F ~ Operating temp: +122°F) -40°C to +70°C (-40°F to Storage temp: Download the audit configuration from +160°F) quincy.scadar.net to your EQ LTE™ base Safety rating: CAT III 600V Useable frequency: 10Hz – 100 kHz station 216mm (8.5”) x 111mm (4.4”) Dimensions: x 45mm (1.8”)
  • Page 17 Note: The use of alternative volt (current clamp) around a conductor carrying measuring devices to the more than 1000 Vac alligator clip set provided with each EQ LTE™ current and Do not attempt to close the jaws of the sensor volt data logger is permissible.
  • Page 18: Technical Data

    Note: Software: Pre-programmed application software • Where possible, we recommend that Sensor: installers use an accessible multi- Type: Ceramic AI (96%) meter to verify the voltage reading. Output: 10 ~ 90% ratio metric, 5VDC +/-5% When verifying the voltage reading Pressure Conn: G¼...
  • Page 19: Technical Data

    work integrity has been checked, remove the Sensor: gas isolation from the pressure sensor. 16bar, depending on medium & Working pressure: temperature For common system pressure, mount the Measuring range: -50° ~ +200°C pressure sensor at a location where the Sensor material: Steel, corrosion protected sensor is exposed to the ‘common’...
  • Page 20: Technical Data

    4.2.12 EQ LTE™ moisture data logger 4.2.12.2 Sensor installation Warning risk high pressure. Isolate gas connection from the compressed air system (e.g. gate or ball valve) before attempting to locate the . Read and moisture sensor understand all safety instructions for both EQ LTE™...
  • Page 21: Technical Data

    4.2.13 EQ LTE™ flow logger positioning the sensor! The safety ring at the sensor head must always remain undamaged and rest correctly in its installed position. The screwed fixture must be pressure tight. The adapter sleeve must be tightened with a torque of 20 to 30 Nm.
  • Page 22: Sensor Installation

    Sensor: Accuracy: ±3% of measured value Fitting: G½” Max Flow: 185 m/sec (607 ft/sec) 50 bar g Max working (750 psi g) press: DIN 1945, ISO 1217 at 20°C and Measurement: 1000mbar a • See air flow measuring range table Measurement L: Length of pipe section range:...
  • Page 23 The angular deviation should not be greater 170.1 558.07 than ± 2° in relation to the ideal position otherwise the measuring accuracy will Argon 289.2 948.81 decrease. Carbon dioxide CO² 183.1 600.72 Nitrogen 164.5 539.69 Air flow measuring range data: Oxygen 176.4 578.74...
  • Page 24: Eq Lte 4 - 20Ma Data Logger

    4.2.13 EQ LTE™ 4 – 20mA logger Self-powered sensor: Note: When using self-powered sensors observe the maximum power rating for the circuit: 24V, 600mA max or 14.4W 4.2.13.1 Technical data Self-powered sensor with alternative source of supply power: Identification: EQ LTE™ Logger, 4 – 20mA Part number: 2014900363 Product family:...