Download Print this page
Digi One IAP Quick Start Manual

Digi One IAP Quick Start Manual

Hide thumbs Also See for One IAP:

Advertisement

Quick Links

Quick Start Guide
Digi One™ IAP, Digi One™ IA, Digi
One™ IAP HAZ
1
Verify your components
Verify that you have all included equipment. If any item is missing or damaged, contact your supplier.
2
Set the DIP switch or screw-terminal pins
1. Set the serial DIP switch according to your serial device requirements (EIA-232/422/485). The pinouts are on the back of the device.
Switch settings
*If switch 4 is up, termination resister is connected.
If down, termination resistor is not connected.
© 2017 Digi International Inc.
Digi, Digi International, and the Digi logo are trademarks or registered trademarks in the United States and other countries worldwide. All other trademarks mentioned in this
document are the property of their respective owners.
Welcome to your Digi product
Get started: This guide helps you with initial product setup. Need more? Find additional
supporting material for this product at www.digi.com/products/serial-servers/digioneiapfamily.
Or connect to the online documentation by scanning this code:
Digi Technical Support: Digi offers multiple support plans to help you get the most out of your
product. For information on Technical Support plans and pricing, contact us at 877.912.3444 or
visit www.digi.com/support.
Documentation feedback: To provide feedback on this documentation, send your comments to
techcomm@digi.com.
Included equipment
DB-9
RS-232
RS-422/485
Full-duplex
2
RxD
RxD+
3
TxD
TxD+
7
RTS
RTS+
8
CTS
CTS+
5
GND
GND
6
DSR
RxD-
1
DCD
CTS-
4
DTR
RTS-
9
NA
TxD-
RS-485
Half_duplex
Screw term
RxD+
6
TxD+
3
Not used
1
Not used
8
GND
5
RxD-
7
Not used
9
Not used
2
TxD-
4

Advertisement

loading

Summary of Contents for Digi One IAP

  • Page 1 TxD- © 2017 Digi International Inc. Digi, Digi International, and the Digi logo are trademarks or registered trademarks in the United States and other countries worldwide. All other trademarks mentioned in this document are the property of their respective owners.
  • Page 2 Off = no link Note Wiring terminals should be tightened to 5 inches per pound. Use copper conductors only. What's next? Download the necessary drivers and utilities from the Product Support section at www.digi.com/products/serial-servers/digioneiapfamily. You can also find additional information at knowledge.digi.com.