Ambiance Fireplaces Intrigue 42 Installation, Operation And Maintenance Manual

Gas fired direct vent fireplace
Table of Contents

Advertisement

WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in
serious injury, death, or property damage.
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance
Do not touch any electrical switch; do not use any
phone in your building
Leave the building immediately
Immediately call your gas supplier from a neighbor's
phone. Follow the gas suppliers instructions
department
installer, service agency or the gas supplier.
English and French Installation Manuals available through your
local dealer or visit our website at: www.archgard.com
Les manuels d'installation en anglais et en français son
disponibles chez votre détaillant local ou en visitant notre site
web: www.archgard.com
INSTALLER:
LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER:
RETAIN THIS MANUAL FOR FUTURE REFERENCE.
ARCHGARD FIREPLACE PRODUCTS
7116 Beatty Drive
Mission, BC V2V 6B4 Canada
INSTALLATION, OPERATION, AND
MAINTENANCE MANUAL
MODEL:
GAS FIRED DIRECT VENT FIREPLACE
S/N 610072 AND UP
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA only) or
mobile home where not prohibited by local codes.
This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use
76.38%
Based on CSA P.4.1-15
UF0110
200-U110-13
January 20, 2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Intrigue 42 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ambiance Fireplaces Intrigue 42

  • Page 1 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL UF0110 MODEL: GAS FIRED DIRECT VENT FIREPLACE S/N 610072 AND UP This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Introduction LIGHT INSTALLATION Safety Information REFLECTIVE PANEL KIT Technical Information REFRACTORY PANEL KIT MEDIA INSTALLATION Installation Codes Glass Bead Installation Mississippi River Rock Installation High Altitude Installation WIRING SCHEMATICS Rating Plate Sample PRESSURE TESTING Installation Checklist SPECIFICATIONS CONTROL SYSTEM COMPONENTS FIREPLACE DIMENSIONS SYSTEM OPERATION...
  • Page 3: Introduction

    General Information Introduction The UF0110 Some of the many features of your UF0110 • • less expensive to operate. • • and heating needs. • • Solid Construction • Optional Accessories • Multiple Electronic Pilot Settings system (also known as a Pilot on Demand (POD)). CPI vs IPI: Continuous Pilot on Demand Ignition (CPI) Intermittent Pilot Ignition (IPI)
  • Page 4: Safety Information

    General Information Safety Information Caution FOR YOUR SAFETY - Do not install or operate your UF0100 without reading and understanding this manual. Any installation or operational deviation from this instruction manual voids the warranty and may prove hazardous. • • •...
  • Page 5: Technical Information

    General Information Technical Information A copy is shown on the following page. Commonwealth of Massachusetts Please contact Archgard Industries Ltd Installation Codes National Fireplace Institute® (NFI) as NFI Gas Specialists. Natural Gas (NG) Propane (LP) Manifold Pressure Min. Supply Pressure Max Supply Pressure Input Rating 76.38%...
  • Page 6: Rating Plate Sample

    General Information Rating Plate Sample DO NOT REMOVE THIS LABEL UF0110 LISTED VENTED GAS FIREPLACE HEATER and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES. Tested to: ANSI Z21.88-2014 / CSA 2.33-2014, CAN/CGA 2.17-M91 (R2009), CSA P.4.1-15, CSA C22.2 No.3 - M1998(R.2014). VENTED GAS FIREPLACE HEATER-NOT FOR USE WITH SOLID FUEL.
  • Page 7: Installation Checklist

    General Information Installation Checklist This standard installation checklist is to be used by the installer in conjunction with, not instead of, the instructions contained within this installation manual. Customer: Date Installed: Install Address: Location of Fireplace: Installer: Appliance Install: IF NO, WHY NOT? Fireplace is leveled and secured.
  • Page 8: Specifications

    Installation SPECIFICATIONS FIREPLACE DIMENSIONS DESCRIPTION Height Width Back Depth Opening Glass Front Floor Front to Width Width Frame Height to Vent to Vent Angled Height Center Center Back (Vert. (Hor. Term.) Term.) FIREPLACE INCHES 34-1/2 40-7/8 30-7/8 19-3/8 35-1/2 26-5/8 16-1/8 33-3/8 8-1/8...
  • Page 9: Uf0110 Components List

    Installation UF0110 COMPONENTS LIST DESCRIPTION Burner Media (purchased separately) Remote Control Light Kit Fan Kit INSTALLATION OVERVIEW NOTE NOTE the installation. or the Canadian Electrical Code CSA C22.1. place. Complete electrical hook-up. Install any standard or optional electrical components. Complete gas line installation. Complete venting installation.
  • Page 10: Prepare The Fireplace

    Installation PREPARE THE FIREPLACE WARNING Use only non-combustible material in Do not Other clearances apply. All clearances must...
  • Page 11 Installation IMPORTANT Bend horizontal heat shield at perforation to a 45° angle. Slide (3) slots on horizontal vent heat shield under loosened screws. Re-tighten screws. NOTE CAUTION...
  • Page 12: Framing

    Installation FRAMING Wall Enclosure Rough Opening IMPORTANT size as necessary to maintain at least minimum clearance requirements. Non –combustible facing material Min. Finished Opening Dimensions NOTE WARNING Provide adequate clearances around air openings into the creating a potentially hazardous situation.
  • Page 13: Optional Full Door Face Dimensions

    Installation Optional Full Door Face Dimensions NOTE Framing NOTE faces. WARNING FIRE HAZARD IMPORTANT WARNING DO NOT RECESS VENT CAP INTO WALL OR SIDING.
  • Page 14: Horizontal Terminations

    Installation Follow vent pipe manufacturer’s installation instructions for horizontal terminations. Include required vent manufacturer’s wall pass-thru clearances when determining framing dimensions. MINIMUM HORIZONTAL FRAMING DIMENSIONS VENT PIPE CENTER (A) FRAMED OPENING TOP (B) RIGID PIPE requirements FLEX PIPE requirements Vertical Terminations Follow vent pipe manufacturer’s installation instructions for vertical terminations.
  • Page 15: Typical Installation Options

    Installation TYPICAL INSTALLATION OPTIONS IMPORTANT Typical Corner Installation Typical Vertical Installation...
  • Page 16: Mantel Requirements

    Installation MANTEL REQUIREMENTS TOP STAND-OFF BRACKETS MUST BE ASSEMBLED AND ATTACHED TO FIREPLACE. DO NOT REMOVE. WARNING STAND-OFF BRACKETS ARE NOT LOAD BEARING Non-Combustible Zone: Rigid Pipe Flexible Venting HORIZONTAL VENT HEAT SHIELD...
  • Page 17: Grill Set

    Installation GRILL SET Installation face. Set down into position. Partially thread (2) screws (included in components packet) into nuts at each end of lower grill. Secure to controls. Removal clips. Lift upper louver up and out of slots. Remove screws securing lower grill at each end to...
  • Page 18: Glass Door Removal And Installation

    Installation Glass Door Removal and Installation WARNING: permanently. Inspect the door gasket to ensure no damage has occurred when installing the glass door. Remove Glass Frame Assembly FIREPLACE BOTTOM FIREPLACE TOP PULL OUT AND DOWN TO RELEASE PULL OUT AND UP TO RELEASE Install Glass Frame Assembly Installation is the reverse of removal.
  • Page 19: Uf0110 Safety Barrier

    Installation UF0110 SAFETY BARRIER • REMOVE TOP GRILL AND HOOD • OPEN BOTTOM GRILLS TO REINSTALL THE BARRIER SCREEN, REVERSE THE • STEPS FOR REMOVAL. • REMOVE SCREEN WARNING DO NOT INSTALL THE BARRIER SCREEN WITH THE GLASS DOOR REMOVED. UF0100/110-BS).
  • Page 20: Gas Line Connection

    Installation GAS LINE CONNECTION Gas Conversion separately). Note: Note: LP (propane) installations require removal of the restrictor under certain vent runs. See venting section for further information. CAUTION connect. NOTE any pressure testing of that system at pressures in excess of 1/2 psi (3.5 kPa). during any pressure testing of the gas line at test pressures equal to or less than 1/2 psi (3.5 kPa).
  • Page 21: Venting

    Installation VENTING WARNING Refer to the vent manufacturer’s installation manual for complete installation instructions. Installation must conform with the venting requirements and restrictions as outlined in this manual. Approved Venting • • • • • • • HORIZONTAL VENT SYSTEM CLEARANCES BOTTOM SIDES ALL APPROVED VENTING...
  • Page 22: Horizontal Terminations

    Installation NOTE CAUTION Vertical Terminations VERTICAL VENT SYSTEM CLEARANCES SIDES ALL APPROVED 1 inch (25 mm) VERTICAL VENTING VERTICAL MIN. / MAX. termination cap. RESTRICTOR SETTING IMPORTANT removal in Gas Conversion section. RECOMMENDED RESTRICTOR SETTINGS VENTING RESTRICTOR POSITION FULL OPEN Min.
  • Page 23 Installation ATTENTION Wall pass-thru required for all horizontal runs. Refer to vent manufacturer to determine which pass-thru will work IMPORTANT within shaded area...
  • Page 24: Termination Vent Cap Location

    Installation Termination Vent Cap Location Terminations against vinyl siding must use a vinyl siding protector. Follow instructions included. Location Clearances centerline of the regulator within a height of 15ft. (4.57 m). US*. mm). NOTE Denotes where installation not allowed...
  • Page 25: Vent Termination Clearances

    Installation Vent Termination Clearances Roof Pitch H (Min.) Ft. H (Min.) m Flat to 6/12 0.30 Over 6/12 to 7/12 1.25 0.38 Over 7/12 to 8/12 0.46 Over 8/12 to 9/12 0.61 Over 9/12 to 10/12 0.76 Over 10/12 to 11/12 3.25 0.99 Over 11/12 to 12/12...
  • Page 26: Light Installation

    Installation LIGHT INSTALLATION CAUTION NOTE cotton gloves when handling. • Remove Screen Barrier*. • • Remove Burner Media*. • Remove Burner Media Tray*. • *REFER TO CORRESPONDING PAGES IN THIS INSTALLATION MANUAL IF NECESSARY. JD Type Halogen MINI-CAN (E11) 35W 120V PILOT...
  • Page 27: Reflective Panel Kit

    Installation REFLECTIVE PANEL KIT CAUTION Glass Panels are fragile. Handle with care. NOTE WARNING to choose from. removing panels. Before you begin: • • • • 3. Place lower glass spacers on edge of 2. Loosen top panel clips / supports and er media.
  • Page 28 Installation 8. Install right side panel clip / support to 9. Slide top glass panel to rest on the rear 10. Continue holding the upper panel in secure side and rear panels. panel and right side panel. place. Slide the upper clips / supports secure.
  • Page 29: Refractory Panel Kit

    Installation REFRACTORY PANEL KIT NOTE instructions. Place right panel. Place the upper panel. secure.
  • Page 30 Installation 12. Place the left panel. white to white) Turn gas on.
  • Page 31: Media Installation

    Installation MEDIA INSTALLATION WARNING quality. Glass Bead Installation Step 1: coverage lighter around the pilot. DO NOT PLACE MEDIA OVER BURNER YET INITIAL MEDIA INSTALL Step 2: Lightly they cannot fall into the pilot opening. PLACE A SINGLE LAYER OVER BURNER AFTER INITIAL MEDIA IS INSTALLED DO NOT COVER...
  • Page 32 Installation Step 3: single layer of glass SINGLE LAYER ONLY ALONG SIDE CHANNELS CAUTION: Never take media from one media tray to add to the other. COMPLETE MEDIA INSTALL...
  • Page 33: Mississippi River Rock Installation

    Installation Mississippi River Rock Installation DO NOT PLACE GLASS BEADS IN THE PILOT OPENING stones. INITIAL MEDIA INSTALL...
  • Page 34 Installation Do not cover the pilot Bridge the Burner channel. DO NOT COVER PILOT OPENING. COMPLETE MEDIA INSTALL...
  • Page 35: Wiring Schematics

    Installation WIRING SCHEMATICS THIS SYSTEM REQUIRES ELECTRICITY (120V) AND / OR BATTERIES TO OPERATE. WARNING USING BATTERY BACK-UP WILL OPERATE BURNER ONLY. FAN AND LIGHT COMPONENTS WILL NOT FUNCTION ON BATTERY BACK-UP POWER.
  • Page 36: Pressure Testing

    Installation PRESSURE TESTING The pressure tap marked OUT measures outgoing pressure and the pressure tap marked IN measures incoming IMPORTANT pressures. NOTE supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa). Inlet Pressure Test: Loosen inlet (IN) pressure tap screw (counter-clockwise).
  • Page 37 Installation FINALIZING THE INSTALLATION Flame Appearance air shutter open too far Correct Pilot Flame air shatter closed too far WARNING technician. FACTORY SET BURNER TUBE AIR SHUTTER SETTINGS (ADJUST AS NECESSARY FOR YOUR INSTALLATION) NATURAL GAS LP (PROPANE) GAS BURNER AIR SHUTTER FULLY OPEN BURNER TUBE AIR SHUTTER ADJUSTMENT GUIDELINES POSITION...
  • Page 38 Installation To Adjust Air Shutter: WARNING AIR SHUTTER 3/16" OPEN (NG) AIR SHUTTER FULLY OPEN (LP)
  • Page 39: Control System Components

    Operation CONTROL SYSTEM COMPONENTS REMOTE CONTROL Continuous Pilot On Demand Ignition (CPI) GAS VALVE PILOT ASSEMBLY...
  • Page 40: System Operation

    Operation SYSTEM OPERATION for the First Time Set ON/OFF rocker switch to OFF position. grill). Connect IFC Control Module to AC power supply NOTE: Performing the next step will initiate Pilot Start-up in Manual • Pilot igniter will spark repeatedly. •...
  • Page 41: Room Thermostat

    Operation Room Thermostat (Remote Control Operation) change to show the room thermostat is ON and set temperature is now desired set temperature is displayed on the LCD screen. Smart Thermostat (Remote Control Operation) and actual room temperature. As room temperature gets closer to set point Press Thermostat key until word SMART appears on right side of temperature is displayed on LCD screen.
  • Page 42: Low Battery Detection

    Operation Low Battery Detection REMOTE CONTROL: BACKUP BATTERY PACK (used when electrical power is interrupted): it receives an ON/OFF command from the remote control. This is an alert powered/ Continuous Pilot On Demand Ignition / Intermittent Pilot Ignition (CPI/IPI) mode icon. Pressing the UP Arrow Key will activate the Continuous Pilot on Demand Ignition mode (CPI).
  • Page 43 Operation Ignition Sequence module will start the spark. First ignition try will last approximately sixty (60) seconds. three (3) times in intervals until the system is reset. LED Indicator Location: LOCK OUT = LED blinks three (3) time in intervals until the system is reset. In Summary: The IFC control module will try two (2) times for ignition.
  • Page 44: Lighting And Shutdown

    Operation LIGHTING AND SHUTDOWN FOR YOUR SAFETY - READ BEFORE OPERATING IF YOU DO NOT WARNING This appliance is equipped with an ignition device which automatically lights the pilot. DO NOT WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance •...
  • Page 45 Operation Operating Instructions Read safety information on the previous STOP! continuing. This appliance is equipped with an ignition ATTENTION device which automatically lights the pilot. DO STOP! proceed to the next step. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance •...
  • Page 46: Maintenance

    Maintenance Maintenance CAUTION: Do not conduct maintenance on the appliance while it is operating or while it is still hot. Always verify proper operation after servicing. Cleaning and Routine Maintenance permanently. Regularly: • HOT. Never use common household cleaners to clean the glass. •...
  • Page 47: Pressure Testing

    Maintenance Pressure Testing Servicing of this appliance WARNING The pressure tap marked OUT measures outgoing pressure and the pressure tap marked IN measures incoming IMPORTANT pressures. NOTE supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa). Inlet Pressure Test: Loosen inlet (IN) pressure tap screw (counter-clockwise).
  • Page 48: 18.3 Flame Appearance

    Maintenance 18.3 Flame Appearance...
  • Page 49 Maintenance NOTE Remove 3 screws securing left side panel retainer. We recommend using a manual screwdriver to avoid damage to components. Remove left side panel. Remove upper left retainer clip. forward to facilitate removal of the upper panel. TOP OF FIREBOX Hold the rear panel and remove the right side panel.
  • Page 50 Maintenance Remove rear panel. Remove upper right retainer clip from right side panel. Remove heat insulation shield.
  • Page 51: Refractory Panel Kit Removal

    Maintenance Refractory Panel Kit Removal NOTE Remove 3 screws securing left side panel retainer. We recommend using a manual screwdriver to avoid damage to components. Remove left side panel. forward to facilitate removal of the upper panel. Remove the upper panel. TOP OF FIREBOX Remove 3 screws securing the right panel retainer.
  • Page 52: Burner Removal

    Maintenance Burner Removal CAUTION wiring harnesses attached to gas valve. media.
  • Page 53: Burner Installation

    Maintenance Burner Installation Secure with screws previously removed. Reinstall media tray using screws previously removed. white to white) 11. Turn gas on.
  • Page 54 Maintenance Issue Solution 1. Ensure the ON/OFF switch is in the ON position. 5. Make sure remote is not in smart or thermostat mode. 2. Check all connections to the gas valve. 5. Check that the pilot is set to the correct fuel. 1.
  • Page 55: Conversion Kit Instructions

    Maintenance CONVERSION KIT INSTRUCTIONS instructions and all applicable codes and requirements of the authority having jurisdiction. If the WARNING agency is responsible for proper installation of this kit. The installation is not proper and complete until • • • CAUTION THE GAS SUPPLY SHALL BE SHUT OFF PRIOR TO DISCONNECTING THE ELECTRICAL POWER, BEFORE PROCEEDING WITH THE CONVERSION.
  • Page 56 Maintenance CONVERT THE GAS CONTROL VALVE: Follow stepper motor pressure regulator instruction sheet included with conversion kit to convert gas valve. (LP or NAT marked on stepper motor pressure regulator). Verify that the following items are present in the package. •...
  • Page 57 Maintenance COMPLETE THE CONVERSION: LP: fully open. Turn on gas and electrical supplies. Test inlet pressure*. *REFER TO CORRESPONDING PAGES IN THIS INSTALLATION MANUAL IF NECESSARY.
  • Page 58 Maintenance Removing Vent Restrictor (LP ONLY): Remove screw securing vent restrictor. Turn the cover over and remove the vent restrictor. *REFER TO CORRESPONDING PAGES IN THIS INSTALLATION MANUAL IF NECESSARY.
  • Page 59: Replacement Parts List

    Maintenance REPLACEMENT PARTS LIST (UF0110) Item # Item Description Unit 200-U110-13 Owner’s Manual 200-U110F-12 314-0009 Glass Gasket (125 inches required) 308-6070 SIT Pro Flame II Electronic Control Module with Continuous Pilot on Demand 308-6022 SIT Pro Flame II Hand held Transmitter 308-6027 SIT 885 Gas Valve c/w Step Motor (0.885.009) 308-6012...
  • Page 60: Limited Warranty

    Warranty Warranty Information 10 Year Limited Warranty manufacture. YEAR 1: YEAR 2-10: transportation or other indirect costs. LIMITATION OF LIABILITY components will make this warranty null and void. the unit. particular purpose. This warranty replaces all previous warranty policies. state to state. Archgard Industries reserves the right to discontinue models and products.
  • Page 61: Lifetime Warranty

    Warranty Lifetime Warranty THIS LIFETIME WARRANTY COVERAGE WILL BE EXTENDED AS DESCRIBED BELOW PROVIDED ALL WARRANTY CONDITIONS AND REQUIREMENTS ARE MET AS OUTLINED IN THE 10 YEAR LIMITED WARRANTY POLICY. LIFETIME WARRANTY COVERAGE tation or other indirect costs arising from defective components. LIMITATION OF LIABILITY connected to this unit.
  • Page 62 NOTES...
  • Page 63 POSTAGE WARRANTY REGISTRATION ARCHGARD INDUSTRIES LTD. 7116 BEATTY DRIVE V2V 6B4 FOLD DOWN AT LINE Why did you choose this product?

This manual is also suitable for:

Uf0110

Table of Contents