Ambiance Fireplaces Intrigue UF0100 Installation And Operating Manual

Direct vent gas fireplace
Table of Contents

Advertisement

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mo-
bile home where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING:
If the information in these instructions is not followed exactly, a fire or explosion may result,
causing property damage, personal injury or loss of life.

WHAT TO DO IF YOU SMELL GAS:

Do not light any appliance
Do not touch any electrical switch: do not use any phone in your building.
Immediately call your gas supplier from a neighbors phone.
Follow the gas suppliers instructions.
If you can not reach your gas supplier, call the fire department.
Do not store or use gasoline or other flammable
vapors or liquids in the vicinity of this or any
other appliance.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier
ARCHGARD FIREPLACE PRODUCTS
7116 BEATTY DRIVE
MISSION , BC V2V 6B4 CANADA
#UF0100
www.archgard.com
www.archgard.com
200-U100
Effective August 20 2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Intrigue UF0100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ambiance Fireplaces Intrigue UF0100

  • Page 1: What To Do If You Smell Gas

    #UF0100 www.archgard.com www.archgard.com INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mo- bile home where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.
  • Page 3 Burner Burner Removal Burner Installation...
  • Page 4 This fireplace has been listed by LABTEST Certification Inc to the following USA and Canada gas appliance standards ANSI Z21.88-2014/CSA 2.33-2014 “Standard for Vented Gas Fireplace Heaters.” CAN 2.17-M19 (R2009), “Gas-Fired for Use at High Altitudes.” CAN/CSA P.4.1-09, “Testing Method for measuring Annual Efficiency The glass assembly, shall only be replaced as a complete unit, as supplied by Archgard Industries Ltd.
  • Page 6 30-7/8 19-3/8 8-1/8 9” 229mm 173mm...
  • Page 7 UF0100...
  • Page 10 FRAMING WALL ENCLOSER ROUGH OPENING Framing dimensions should allow for wall covering thickness and fireplace facing materials. If using a hearth, adjust rough opening size as necessary to maintain at least minimum clearance requirements. TANT IMPOR Non –combustible facing material may be applied over (but not directly to) fireplace face. This will prevent facing material from falling off due to heat expansion.
  • Page 11 FRAMING Determine exact position of your fireplace, including hearth height, width, and depth (if applicable). If possible, place fireplace in such a manner that vent termination will be between two studs, eliminating the need for additional framing. If masonry is to be used (optional), prepare the necessary foundation for the masonry load. When masonry construction is used, a lintel must be used over top of fireplace to support the added weight.
  • Page 12 12 10...
  • Page 13 SNOKEL TERMINATION 13 11...
  • Page 14 11” WC (2.74 kPa) 7" WC (1.74 kPa) 10” WC (2.49 kPa) #56 & #33 #62 & #49...
  • Page 15 VENTING Consult the local and international codes to assure adequate combustion and ventilation air is available. Flame height and appearance will very depending upon venting configuration and type of fuel used. WARNING Venting requirements apply to both Natural and LP gas. Refer to the vent manufacturer’s installation manual for complete installation instructions.
  • Page 16 3ft. Pipe 90º Elbow Snorkel 1ft. Pipe Termination Minimum 6” (152mm) Maximum 24” (609mm) 45º Elbow Snorkel Termination 3ft. (915mm) 3ft. (915mm) 16 14...
  • Page 17 10 12 18 20 22 24 26 28 30 Note: Horizontal venting 3ft and under, must use a snorkel style termination 1’...
  • Page 18 18 16...
  • Page 19 19 17...
  • Page 20 UF0100 LOG SET INSTALLATION Black Embers should be placed in open areas and as not to completely block burner ports.
  • Page 21 BUNRER REMOVAL...
  • Page 22 BUNRER INSTALLATION Place burner in firebox, aligning holes in burner to holes in fire- box bottom. Make sure gasket is in place on firebox bottom. Secure with screws previously removed. 22 20...
  • Page 24 24 22...
  • Page 26 26 24...
  • Page 29 29 27...
  • Page 30 30 28...
  • Page 32 Pressure check taps for manifold (outgoing) and inlet (incoming) pressure have been incorporated into the valve. The pressure tap marked OUT measures outgoing pressure and the pressure tap marked IN measures incoming pressure. Follow instructions below for proper testing procedures. Refer to page 14 for proper NAT and LP manifold pressures.
  • Page 33 33 31...
  • Page 36 36 34...
  • Page 38 Part # UA2000: NG - LP Conversion Kit UA2100: LP - NG Conversion Kit Kit includes: (1) Gas Conversion Label (2) Burner Orifices LP #49 & 62 / NG #33 & #56 (301-0068) (1) Step Motor Pressure Regulator ( 308-6018 (LP) & 308-6010 (NG) ) Remove existing orifice caps.
  • Page 40 REPLACEMENT PARTS LIST (UF0100) Item # Item Description Unit 200-0100 Owner’s Manual 314-0009 Glass Gasket (125 inches required) 308-6011 SIT Pro Flame II Electronic Control Module 308-6014 SIT Pro Flame II Handheld Transmitter 308-6027 SIT 885 Gas Valve c/w Step Motor (0.885.009) 305-6002 Module Main Wiring Harness (5 wire) 305-6003...
  • Page 41 This limited 10 Year Warranty will not become effective until the Warranty Registration Form has been completed and mailed to Archgard Fireplace Products 7116 Beatty Drive, Mission, BC V2V 6B4 Canada. This registration form must be received within 30 days of installation. Failure to do so may result in delayed warranty coverage and submission of proof of purchase will be required.
  • Page 43 LIFTIME WARRANTY COVERAGE LIFTIME WARRANTY IS EXTENDED AS FOLLOWS: Archgard Fireplace Products warranties the original purchaser that the firebox, heat exchanger, fiber logs, burner tube and glass panel of this Ambiance Fireplace will not be defective in material or workmanship under normal use and service for as long as you own this product.

Table of Contents

Save PDF