Water Connections - Bradford White DS140S Installation And Operating Instruction Manual

Bradford white installation & operating instruction manual direct vent gas water heater ds140s & ds150s
Table of Contents

Advertisement

Installation continued-

WATER CONNECTIONS

Note: BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE
MAIN WATER SUPPLY VALVE.
After shutting off the main water supply, open a faucet to relieve the water line
pressure to prevent any water from leaking out of the pipes while making the
water connections to the water heater. After the pressure has been relieved,
close the faucet. The COLD water inlet and HOT water outlet are identified on
the top of the water heater. The fittings at the cold water inlet and hot water
outlet are dielectric waterway fittings with 3/4" NPT male thread. Make the
proper plumbing connections between the water heater and the plumbing
system to the house. Install a shut-off valve in the cold water supply line.
If sweat fittings are to be used, DO NOT apply heat to the nipples on top of
the water heater. Sweat the tubing to the adapter before fitting the adapter
to the water connections. It is imperative that heat is not applied to the
nipples containing a plastic liner.
CAUTION
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds150s

Table of Contents