VISLINK
Waveguide Switch Position
Command:
Response:
x
A: Position A. [= X(H)]
B: Position B. [= Y(V)]
M: Moving
E: Error
State
Command:
Response:
A
System mode
B
System Monitoring
C
System State
D
Azimuth State.
E
Elevation State.
F
Polarisation State.
G
Axis 4 state.
H
Axis 5 state.
Axis states as system states, excluding measuring and halted.
Limit States
Command:
Response:
A
Azimuth limits
B
Elevation limits
C
Polarisation limits
D
Axis 4 limits
E
Axis 5 limits
Limit coding
Newswift 90-180 Motorised Antenna
QUW
UWx
QUS
USABCBEFGH
O: Operational
T: Test
U: DUT
1:
On
0:
Off
a: STOWED.
b: STOWING.
c: DEPLOYED.
d: DEPLOYING.
e: CALIBRATING.
f: HALTED.
g: MEASURING. (Test Mode Only)
QUL
ULABCDE
a: OK.
b: Clockwise softlimit.
c: Anti-Clockwise softlimit.
d: Clockwise freewheel.
e: Anti-Clockwise freewheel.
f: Clockwise travel limit.
g: Anti-Clockwise travel limit.
h: Clockwise Stall.
38