VISLINK
Abort calibration procedure
Command:
Response:
The calibration responses and final results are output using the QUD responses. (C100
compass calibration only.)
Reset Pitch Angle (HMR3300 only)
Command:
Response:
Sets the HMR3300 pitch angle to 0°.
Reset Roll Angle (HMR3300 only)
Command:
Response:
Sets the HMR3300 roll angle to 0°.
.
Read compass magnetic offset values (HMR3300 only)
Command:
Response:
±xxxxx
±yyyyy
±zzzzz
Values are only read from compass on link initialisation at power up or compass
serial link reset.
Reset compass magnetic offset axis value (HMR3300 only)
Command:
Response:
a
Newswift 90-180 Motorised Antenna
WCSCA
WCSCA
WCRPA
WCRPA
WCRRA
WCRRA
RCMOF
RCMOF±xxxxx±yyyyy±zzzzz
Current X axis magnetic offset value.
Current Y axis magnetic offset value.
Current Z axis magnetic offset value.
WCMOVa
WCMOVa
: Axis Control.
'X' : Resets X-axis magnetic offset to zero.
'Y' : Resets Y-axis magnetic offset to zero.
'Z' : Resets Z-axis magnetic offset to zero.
'A' : Resets all magnetic offset axis values to zero.