Alarms; F1: Dcu Power Supply Voltage Low - Advent VISLINK Newswift 90 Technical Operation Handbook

Table of Contents

Advertisement

VISLINK
4.17

ALARMS

The following table lists all the alarms for the DCU4000. If the alarm is latched, the alarm is
cleared by using the clear alarm command. These are coded into the remote command set
as described in section 4.36.
DCU power supply voltage low.
DCU motor supply failure.
Motor drive module inhibit.
Inclinometer failure.
Inclinometer suspect.
Drive stall detected.
Drive freewheel detected.
Drive end of travel detected.
Waveguide polarisation switch failure.
Azimuth sensor failure.
Elevation sensor failure.
Polarisation sensor failure.
DCU FPGA programming failure.
Manual brake override on.
Azimuth stowing failure.
Elevation stowing failure.
Polarisation stowing failure.
Power up state suspect.
Stow sensor power supply error.
MRD power supply error.
Inclinometer power supply error.
FPGA watchdog triggered.
Hand held controller active.
Fin 1, 2, 3, 4, 5 over temperature.
WGS power supply error.
Brake power supply error.
Fan power supply error.
Azimuth, elevation brake disconnected.
E2PROM checksum error.
Softlimit data error.
Wooded area data error.
Calibration area data error.
FPGA compatibility warning.
External flash erasing/writing error.
4.18

F1: DCU POWER SUPPLY VOLTAGE LOW

The antenna DCU has measured a voltage below 9.5V at the antenna electronics. The
voltage supplied from the 12V nominal supply is approaching the minimum required to drive
the antenna. Action should be taken to boost the 12V supply to the DCU.
Newswift 90-180 Motorised Antenna
B rief Description
U
A larm Latched