Maintenance - Timberk AC TIM 18LC CF5 Instruction Manual

Electric air conditioner, split system
Table of Contents

Advertisement

8. MAINTENANCE

Before cleaning switch the conditioner off.
Cleaning of the indoor unit and remote control board:
Indoor unit and remote control board should be cleaned with a dry soft
cloth.
If the indoor unit is too unclean, moisten the cloth with cold water.
It is prohibited to clean the remote control board with moist cloth.
In order to avoid the damage of paint or details of the conditioner, do not
clean it with brushes and do not leave them on the surface of indoor unit.
In order to avoid the damage of surface or deformation of the conditioner
details, do not clean it with petrol, solvents, cleaning powders or other
chemically active substances.
Before a sustained interruption in the conditioner work:
Turn the conditioner on for several hours in the FAN mode. It will allow you
to dry its inner cavities
Switch the conditioner off.
Remove the batteries from the remote control board.
Checks before starting:
Make sure that an air filter is installed.
Make sure that air inlet and return air grillages of the outdoor unit are not
blocked by foreign objects.
Cleaning of air filter
Air filter cleans the air entering the conditioner from dust and foreign
particles. If the filter is contaminated, the conditioner capacity decreases
sharply. If the conditioner is operated permanently, the filter should be
cleaned once per two weeks.
If the conditioner is installed in a room with dusty atmosphere, then the air
filter should be cleaned more often.
To remove the filter, open the air inlet of the indoor unit panel. Press the
locks to the center and pull the grillages down. Remove the air inlet.
Remove the air filter. Clean the filter with a vacuum cleaner or rinse it in
clean water. If the filter is contaminated heavily, clean it with a soft brush
and wash in diluted washing solution, then dry it in a cool place.
While cleaning the filter with the vacuum cleaner, hold it with contaminated
surface up. While washing the filter in water, hold it with contaminated
surface down.
Do not dry the filter in the sun or near a fire.
Set the air filter to initial position and close an air inlet cover
9. TROUBLESHOOTING
Failures and their possible reasons:
Failure
Possible reason
Interruptions in power supply
Batteries in the remote control
The conditioner does
board are low
not work
Time of tuming on is set by
the timer
The set air temperature is too
high or too low
Insufficient cooling or
The air filter is clogged with dust
heating capacity
Foreign objects block the air intel
and retum air grillages of the
outdoor unit
A three-minute delay of
The conditioner works,
compressor tuming on
but does not cool or
The air temperature is set
heat the room
incorrectly
www.timberk.com • Electric air conditioner
Actions
Wait for restoration of power
supply
Replace the batteries
Wait till the conditooner turns
on by the timer or cancel the
timer setting
Set the air temperature
correctly
Clean the air filter
Remove foreign objects
Wait a little
Set the temperature correctly