Powder Feeder - Bayer HealthCare SeedGrowth CBT Series Maintenance Manual

Table of Contents

Advertisement

PoWDEr fEEDEr

8
PoWDEr fEEDEr
Step 1:
At the end of each treating session or whenever the operator
needs to change powder product, run all of the powder out of
the powder hopper. Since powder absorbs ambient air moisture
and solidifies if left over time, cleaning helps prevent "caking up".
Release the powder tube assembly clamps to remove it from the
powder feeder and the mixing bowl cover. Clean thoroughly.
Connected to
Bowl Cover
Step 2:
Use 1/2" wrench to remove the four nuts that hold the auger
tube and gasket onto the backside of the powder base. Slide the
auger tube and gasket from the powder body. Clean thoroughly.
Step 3:
the machine.
Connected to
Auger Tube
See assembled
images Step 6
on page 9.
Always use a vacuum (not compressed air) to safely clean