PM cHEcKlISt
cbt bowl & frame PM checklist
1:
Check/drain filter/regulator - Quarterly
2:
Clean area under bowl - Weekly
3:
Inspect atomizer belt - Weekly
4:
Inspect bowl gearbox for oil leaks - Weekly
5:
Inspect bowl gearbox oil level - Quarterly
6:
Replace bowl gearbox oil - 25,000 hrs
7:
Clean bowl / wrap gap - Weekly
8:
Clean inside of bowl /wrap / lid - per Shift
9:
Inspect air filter for under bowl blower - Monthly
Atomizer
Use 7/16 socket head to remove the 1/4 bolt, washer and lock washer
that connects the atomizer to the drive shaft. Remove the atomizer
and clean residual chemical. Wipe down the bowl and inside the
bowl cover. Replace the atomizer on the drive shaft and securely
tighten in place.
Move the bowl cover / Swing arm over the mixing bowl and latch each
hold down clamp securely. Replace the chemical inlet plate on the
mixing bowl cover. Tighten the four (4) wing nuts on the chemical inlet
plate.
blower filter
Use the quarter turn key to unlock and remove the left panel door from
the bowl support frame. Loosen and remove the wing nut holding
the filter housing. Check the filter element and replace if needed
(P000544). Replace the filter housing and tighten the wing nut in
place.
MIXINg boWl
15