  • Page 1 Stationary unit with self-cleaning filter Installation and user manual www.plymovent.com...
  • Page 2: Table Of Contents

    To improve comprehension for people whose first language is not English, we have written parts of this manual in Simplified Technical English (STE). STE is a controlled language originally developed for aerospace industry maintenance manuals. It offers a carefully limited and standardized subset of English, along with specific writing rules. 0507320010/150720/E SFS...
  • Page 3: Preface

    General description This manual is intended to be used as a work of reference for The SFS is a stationary welding fume filter for use with one professional, well trained and authorised users to be able to extraction arm and fan. The filter cartridge is provided with a safely install, use, maintain and repair the product mentioned precoat to extend the lifespan and efficiency of the filter.
  • Page 4: Product Description

    Dimensions Operation Refer to Fig. I on page 10. The SFS works in accordance with the recirculation principle. Welding fume is extracted through the hood of the connected Pressure drop extraction arm by a fan. The polluted air first passes the prefilter box that separates the larger particles and sparks, if Refer to Fig.
  • Page 5 In case of doubt it is the use which can be deduced from the construction, the model and the function of the technical product which is considered normal use. Operating the machine within the limits of its intended use also involves observing the instructions in the user manual. 0507320010/150720/E SFS...
  • Page 6: Installation

    Fig. 4.1 - Install the SFS (E) in such a way that the inlet opening (D) is horizontally in line with the outlet opening (B) of the fan (A). - In the standard set-up the SFS (E) is positioned on the right Inlet openings: side of the fan (A).
  • Page 7: Use

    If necessary, install a pressure reducing valve to prevent unwanted activation of the safety valve. • Connect the compressed air hose to the reducing nipple (1/4” internal) on the lef side of the SFS. 4.3.5 Electric connection The CB control box provides 24 VAC power to the cleaning RoboClean™...
  • Page 8: Maintenance

    5.3.1 Normal operation During normal operation the SFS functions fully Component Action Frequency: every X independently; the extraction fan blows the welding fume into months the filter unit.
  • Page 9: Troubleshooting

    (ref. Fig. 5.1A) is off. the facility ripped or cartridge or place it placed correctly You must empty the dust barrel: incorrectly - when it is full - (preferably) when you have replaced the filter cartridge 0507320010/150720/E SFS...
  • Page 10: Spare Parts

    - Replace the coil CE declaration of conformity for machinery - control PCB is - Replace the defective control PCB We, Plymovent Manufacturing B.V., Koraalstraat 9, 1812 RK Alkmaar, Netherlands, herewith declare, on - Pressure - Replace the difference pressure...
  • Page 11 B = Airflow (m3/h) A = Static pressure (Pa) 1 = Clogged filter 2 = Clean filter inch 28.3 26.4 26.0 14.2 Ø 160 Ø 6.30 36.2 20.3 Ø 160 Ø 6.30 1.77 5.12 Ø 330 Ø 13.0 0507320010/150720/E SFS...
  • Page 12 ANNEX Fig. III Installation measurements inch inch 2773 109¼ 1177 46¼ ™ 2670 >850 33½ 2599 102¼ 11½ 2789 109¾ 18½ 1889 74¼ 16¼ 0507320010/150720/E SFS...
  • Page 13 [not shown] 0000102274 Spark arrester 0046030010 Safety valve 6-10 bar for compressed air tank 0000102277 Control lamp 28V, yellow 0690150070 Lock 0000102283 PC board control MFS/SFS 0806010160 Handle barrel 0000102286 Reset/start button 0809040040 Cover Ø 160 mm 0000102291 Sealing ring 9822010010...
  • Page 14 0507320010/150720/E SFS www.plymovent.com...