General data
Version
Housing material
Weight approx.
Electrical characteristics
Operating voltage/Signal
Ʋ B63-48
Ʋ B63-32
Leakage current at nominal voltage
Max. permissible current
Internal resistance
Response voltage (1 kV/µs)
Response time
Discharge current
Band width
Electromechanical data
Screw terminals for cable cross-section
Number of wires
Wire cross-section
Cable length
Ambient conditions
Ambient temperature
Storage and transport temperature
Moisture
Electrical protective measures
Protection in assembled and connected
state
Approvals
Instruments with approvals can have different technical specifications depending on the version.
Reference temperature 25 °C (77 °F).
3)
14
The device can be screwed into the sensor housing
instead of the cable gland
316Ti
175 g (0.385 lbs)
3)
9 ... 48 V DC/4 ... 20 mA/HART
9 ... 32 V DC/Profibus PA, Foundation Fieldbus
< 10 µA
1 A
1 Ω
< 76 V
< 1 µs
< 10 kA (8/20 µs)
1 MHz
< 1 mm
two signal cables, one ground cable
1.5 mm
250 mm (9.843 in)
-40 ... +85 °C (-40 ... +185 °F)
-40 ... +85 °C (-40 ... +185 °F)
5 ... +95 °% (non-condensing)
IP 66/67
B63-48, B63-32 • For 4 ... 20 mA/HART, Profibus PA and Foundation Fieldbus circuits
(AWG 18)
2
(AWG 14)
2

Advertisement