Calibration Procedure As Per Iec 61000-4-5 Ed3; General; Calibration Procedure For Cdns For Unsymmetrical Interconnection Lines - Ametek CDN 117A Series Operating Manual

Coupling network for surge and ring wave to signal and datalines
Table of Contents

Advertisement

AMETEK CTS
6.4.

Calibration procedure as per IEC 61000-4-5 Ed3

6.4.1.

General

It is recommended and sufficient to calibrate the CDNs for interconnection lines in the same configuration that
will be used for testing. The residual surge voltage measured between the surged lines and ground on the AE
side of the CDN, with the EUT and AE equipment disconnected, shall be measured and recorded so that users
of the CDN may determine if the protection is sufficient for use with a particular AE.
6.4.2.

Calibration procedure for CDNs for unsymmetrical interconnection lines

Measurements shall be performed with the impulse applied to one coupling path at a time.
The peak amplitude, the front time and impulse duration shall be measured for the CDN rated impulse voltage
and current at the EUT output port according to (Table 7 of IEC 61000-4-5 Ed3.0).
The inputs of the decoupling network at the AE side shall be short-circuited to PE for the impulse voltage and
impulse current measurement at the EUT output port.
The residual voltage value depends on the protection requirements of the AE. Therefore, no limits are given in
this standard.
Surge voltage
at EUT side
Surge current
at EUT side
Surge voltage
at EUT side
Surge current
at EUT side
Residual voltage
on AE side (with protec-
tion elements)
Table 7 IEC 61000-4-5 Ed3.0 Summary of calibration process for CDNs for unsymmetrical interconnection lines
Operation Manual
Coupling
Single line to PE
Single line
Peak voltage,
front time, duration
Single line to PE
Single line
Peak current,
front time, duration
Single line to line
Single line
Peak voltage,
front time, duration
Single line to line
Single line
Peak current,
front time, duration
Single line to PE
Line to PE at a time
peak voltage
Measuring
All lines shorted to PE
All lines shorted to PE
All lines shorted to PE
All lines shorted to PE
Open–circuit
V 1.00
CDN 117A series
AE side
EUT side
Open–circuit
Short-circuit
Open–circuit
Short-circuit
Open–circuit
20 / 30

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdn 117a-c4-4-1Cdn 117a-c6-4-1

Table of Contents