5.
When the command has been executed, turn the
unit off and then turn it on again.
The MRS-1266 will operate in normal mode.
Test/restore integrity of data on inter-
nal hard disk (ScanDisk)
This action serves to test the disk and perform restorative
action if necessary. Try this command when the unit operates
unstably.
N
OTE
ScanDisk may not be able in all cases to restore damaged
files. To guard against data loss, it is recommended to
regularly back up data from the hard disk onto CD-R/RW
discs.
1.
Refer to steps 1 - 3 of "Basic maintenance
procedure" to bring up the indication "ScanDisk"
on the display. Then press the [ENTER] key.
The ScanDisk menu appears.
AutoRepr
AutoRepr
å
å ENT
2.
Use the cursor left/right keys to select the
ScanDisk function.
● AutoRepr (Auto Repair)
This function tests all files on the hard disk and
automatically repairs damaged files.
● ChekFile (Check File)
This function only tests all files, but does not automatically
repair them. If a problem is found, a message is displayed on
the screen.
3.
To execute the selected function, press the
[ENTER] key.
ScanDisk starts.
N
OTE
Once ScanDisk has started, it cannot be interrupted by the
user. Never turn power to the unit off while ScanDisk is
158
ENT
running. Otherwise the hard disk may be destroyed.
4.
When ScanDisk is completed, press the [EXIT] key.
The unit returns to the condition of step 1.
Overwriting the system file data
(Factory Initialize)
This action overwrites the operating files such as system file.
Projects created by the user are not affected by this
operation. Try this command when the unit operates
unstably after the above ScanDisk operation.
1.
Refer to steps 1 - 3 of "Basic maintenance
procedure" to bring up the indication "Init Fac" on
the display. Then press the [ENTER] key.
The indication "Init Fac SURE?" appears on the display to
confirm the operation.
Init Fac
Init Fac
SURE?
SURE?
2.
To carry out the initialization process, press the
[ENTER] key once more.
The factory initialize process starts. When it is complete, the
unit returns to the condition of step 1

Formatting the hard disk

This action formats the hard disk and writes the operating
files. All existing projects containing the demo song will be
erased.
N
OTE
Once erased, user-created projects cannot be restored. Use
this function with extreme care. If you want to preserve
projects, back them up to CD-R/RW disc first (
1.
Refer to steps 1 - 3 of "Basic maintenance
procedure" to bring up the indication "Init ALL" on
the display. Then press the [ENTER] key.
The indication "Init ALL SURE?" appears on the display to
confirm the operation.
p. 142).