Download Print this page

Technical Specifications; Ordering Information - Zhone IPD 12000E Datasheet

Broadband loop carrier

Advertisement

Technical Specifications

Dimensions
Nine (9) Rack-Units high
15.75" H x 17" W x 18" D
40cm H x 43.2cm W x 46cm D
Weight
47 lbs (21.4 kg) (chassis only)

Ordering Information

SYSTEM CHASSIS
IPD12000E-19
IPD12000E-19EF
IPD12000E-23
IPD12000E-23EF
MCM4E
MCM6
UPLINK & INTERFACE MODULES
BSX8000-5
BSX8000-5R
MIM
ACCESS MODULES
AEM100-16
AIM24000-48
AIM29000-48
EIM2000-24
ESIM5700-48
SIM2000-24
TIM1500-24
MODULAR POWER CONVERTER
MPC
IPD 12000E Broadband Loop Carrier (BLC)
Power
AC - Requires External AC to -48 Volt DC Power
Converter
DC - Redundant -48 VDC Terminal Blocks
30 A maximum; 15 A typical*
*actual power consumption dependent upon
chassis configuration
Interfaces
14 slot chassis:
- 12 Access Module slots (front)
- 2 Broadband Services Switch (BSX) slots (front)
- 24 RJ-21 (50-pin) Telco Connectors (rear)
IPD12000E Chassis with Legacy Fan Tray and 19" rack mounting brackets
IPD12000E Chassis with Enhanced Fan Tray and 19" rack mounting brackets
IPD12000E Chassis with Legacy Fan Tray and 23" rack mounting brackets
IPD12000E Chassis with Enhanced Fan Tray and 23" rack mounting brackets
Spare / Replacement Fan Tray (Legacy with four (4) fans)
Spare / Replacement Fan Tray (Enhanced with six (6) fans and Fault Tolerant Controller)
Broadband Services Switch 8000 for IPD 12000E/4000E (with EAPS support)
Broadband Services Switch 8000 w/Redundant Messaging (for use in pairs and IPD12000E chassis)
Micro Interface Modules (MIM) for the BSX8000-5 and BSX8000-5R cards
16-port Active Ethernet Module for the IPD
48-port ADSL2+ Line Card (Conexant chipset)
48-port ADSL2+ Line Card (Broadcom chipset)
24-port E1 Inverse Multiplexer Module
48-port Ethernet SHDSL.bis Inverse Multiplexer Module
24-port SHDSL Inverse Multiplexer Module
24-port T1 Inverse Multiplexer Module
Modular AC-to-DC Power Converters
Regulatory Compliance
NEBS: GR-63-CORE, GR-1089-CORE
EMC: FCC Part 15, CSA C108.8, EN55022,
EN55024, CE Marking
Safety: UL1950, CSA C22.2 No. 950, EN60950,
CE Marking
Operating Requirements
Temperature: 32ºF to 122ºF (0ºC to 50ºC)
Non-operating temperature: -40ºF to 158º F
(-40ºC to 70ºC)
Humidity: 5% to 95%, non-condensing
Altitude: -200ft to 16,500ft (-60m to 5,000m)
17 December 2010 11:38:30

Advertisement

loading
Need help?

Need help?

Do you have a question about the IPD 12000E and is the answer not in the manual?