Page 3
Software; (c) Used so as to circumvent any technological measure included therein or provided by Zhone from time to time to control access to or limit use of the Software; (d) sublicensed, rented, leased or lent to third parties; (e) imported or exported into any jurisdiction except in compliance with all applicable laws of the United States and such jurisdiction;...
C.F.R. 227.7202-1 to 227.7202-4, U.S. Government Users acquire the Software only with the rights set forth therein. Third Party Licensors. This Zhone End User License Agreement may be accompanied by differing or additional provisions applicable to portions of the Software provided by one or more Licensors ("Licensor Provisions").
If the equipment includes a ferrite choke or chokes, they must be installed per the installation instructions. 4929 DSLAM Installation and User’s Guide...
Page 6
Numbers of all the devices does not exceed five. CE Marking When the product is marked with the CE mark on the equipment label, a supporting Declaration of Conformity may be downloaded from www.zhone.com. Japan Class A ITE This is a Class A product based on the standard of the Voluntary Control Council for interference by Information Technology Equipment (VCCI).
BOUT UIDE Document Purpose and Intended Audience This document is written for technicians who install the 4929 DSLAM. Document Summary Section Description Chapter 1, Introduction Describes the 4929 DSLAM Chapter 2, Installation Describes the physical installation of the into a rack.
Describes how to install the MIM-4E1 Micro Interface Module. MIM-4T1 Installation Instructions Describes how to install the MIM-4T1 Micro Interface Module. ® GrandVIEW EMS User’s Guide Contains instructions for maintaining network services and resources using the GrandVIEW Element Management System (EMS). 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Contacting Global Service and Support Contacting Global Service and Support Contact Global Service and Support (GSS) if you have any questions about this or other Zhone products. Before contacting GSS, make sure you have the following information: Zhone product you are using...
Page 14
4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Small enough to fit in any remote terminal; ETSI standard form factor for 19” and 23” racks 24 ports of ADSL/ADSL2/ADSL2+ (ITU G.992.5), Annex A Modular, hot-swappable media independent backhaul using the following Micro Interface Modules: MIM-10/100, MIM-100FX, MIM-2E1, MIM-4E1, MIM-2T1, MIM-4T1, or MIM-2000F 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Page 16
Embedded web-based management system for easy, platform-independent remote management, and SNMP for remote monitoring IGMP snooping for multicast video support Available with integral 600 Ohm POTS splitters, 900 Ohm POTS, or ISDN splitters 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Different models can be mixed in a stack. Power – The DSLAM operates from a –48 VDC power supply to allow for standard power connections available in a CO. For AC voltage environments, an external AC-to-DC power converter is required. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Category 5 or better unshielded twisted pair (UTP) cable. Up to four required. DB9 to RJ45 adapter cable. The 4900 Series DSLAM to a terminal or a PC with a terminal emulation program. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Wall mount – see Installing the DSLAM on a Wall on page Shelf or desktop – see Installing the DSLAM on a Shelf or Desktop on page 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
23-inch (584 mm) Bay Networks or Nortel rack are shipped with the unit. To install the mounting brackets for rack mounting: 1 Identify eight flat-head screws provided with the mounting brackets. 2 Attach the brackets appropriate to your rack size. Tighten all screws firmly. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
DSLAM will be fastened. 02-17070 2 Place the unit so that the brackets rest against the front of the rails. Insert screws in the bottom screw positions and hand-tighten them. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
23-inch rack. Two screws are required for each bracket. 2 Lay the unit upside down on a flat surface. 3 Locate the pair of threaded holes on the right side of the unit. Attach a bracket using the flat-head screws. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Page 23
7 Install two wood screws (not provided) at the points you have marked. Do not completely tighten the screws. Leave them so their heads are about 1/4 inch (6 mm) from the wall. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
4 Turn the unit right side up and place it in position on a shelf or desktop. 5 If the installation includes more than one unit, one can be stacked atop another. Up to eight units can be stacked together. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Connecting the ADSL2+ and POTS Connectors on page 27 Connecting the SFP Connector or the 10/100/1000 Connector on page 28 Connecting the COM Port on page 30 Connecting to Power on page 31 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
3 Slide the MIM into the chassis until it is fully seated. 4 Secure the MIM by tightening the fastening screws on the MIM faceplate with a flat-head screwdriver. 5 Cable the MIM as described in the MIM installation instructions. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Attach the cable connector to the unit using the long captive screw. 4 Tighten the cable tie around the connector and trim the excess. 02-17084 5 If you are using an integrated POTS splitter, repeat Step 1 through Step substituting POTS for ADSL2+. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Interface (MDI) and an MDI Crossover (MDIX). Install the supplied small ferrite choke on the cable as close as possible to the jack. Use a cable tie to hold the choke in place. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
4900 DSLAM, or to the uplink interface. The connection to the downstream DSLAM must be specified. This is done using the web interface. See DSLAM Interconnect Configuration in Chapter 5, Configuration Using the NMS. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Appendix A, Connectors and Pin Assignments. 3 Connect the modular plug of your cable to the COM port socket. 4 Connect the other end of the cable to the serial port of your terminal or 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
8 Insert your positive DC power lead into the positive (+) terminal and then tighten the screw. 9 Repeat Step 6 through Step 8 if you have a redundant power source. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Page 32
Cabling 10 Turn on your power source and verify that the Power LED on the left side of the DSLAM is illuminated. See Chapter 4, LEDs. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
No link or no activity. Green Flashing Transmitting or receiving. 10/100/1000 Dup – Half-duplex or no link. Green Full-duplex link. DSL Ports 1–24 LK – No DSL link present. Green DSL link present. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Page 34
Meaning DSL Ports 1–24 ACT – No activity or no link. Amber Flashing Receiving data. Green Flashing Transmitting data. Green No power is applied to the DSLAM. Power is applied to the DSLAM. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
NMS screens to exceed the width or height of the screen. To verify screen resolution on a Windows system: — Right click on your desktop — Select Properties — Click the Settings tab — Adjust the Screen Resolution as needed 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
9 Start your web browser. Type 192.168.254.252 into the Address field and press Enter. The web server opening screen appears. 10 Click on >> Next >>. The login dialog box appears. Log in using: Username: superuser Password: Password 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Page 37
Configuring Your Windows PC to Communicate with NMS The NMS home page appears. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Check this box if you will use inband management through MIM ports or ADSL ports. VLAN Id Specify a VLAN identifier for inband management. Priority Specify a priority (0–7) for management traffic. 3 Click on Submit. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
DSLAM will be lost when you click on Submit. Communication Tools Click in the On or Off buttons to enable or disable TFTP and Telnet on this DSLAM. 3 Click on Submit. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Specify the current password for the General or Superuser login. The default setting is Password. New Password Specify the new password for the General or Superuser login. Confirm New Type the new password again. 3 Click on Submit. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Specify the IP addresses of hosts that are to receive trap notifications. SNMP Traps Click in the check boxes to enable or disable SNMP traps: snmpAuthentication snmpEnvironment snmpColdStart snmpModule/Port 3 Click on Submit. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Specify the current community name for Read or Read/Write operations. The default for both is Password. New Community Specify the new community name for Read or Read/Write operations. Confirm New Type the new community name again. 3 Click on Submit. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Ctrl key while clicking on your selections. 3 Select or enter the following parameters: Parameter Description Reset Port Statistics Click in this box to reset statistics when the Submit button is clicked on. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Page 44
DHCP Server to limit the number of IP addresses assigned per port. VPI and VCI Specify a default VPI and VCI if VPI/VCI Detect Setting (above) is Off. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
3 Select or enter the following parameters: Parameter Description Reset the DSCP Range Click in this box to reset DSCP Range rules rules to default when the Submit button is clicked on. parameters 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Page 46
Add VLAN to Ingress Specify whether the VLAN ID should be added Pkt. to ingress packets. Priority Specify the priority to be used when adding a configured VLAN ID to a packet. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Specify the egress limit in kbps for packets matching this rule. 4 Click on Submit. Global IP Rules To configure IP rules: 1 Click on the Global IP Rules tab. The Global IP Rules screen appears. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Page 48
Add VLAN to Ingress Specify whether the VLAN ID should be added Pkt. to ingress packets. Priority Specify the priority to be used when adding a configured VLAN ID to a packet. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Specify the egress limit in kbps for packets matching this rule. 4 Click on Submit. Global MAC Rules To configure MAC rules: 1 Click on the Global MAC Rules tab. The Global MAC Rules screen appears. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Page 50
Add VLAN to Ingress Specify whether the VLAN ID should be added Pkt. to ingress packets. Priority Specify the priority to be used when adding a configured VLAN ID to a packet. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Specify the egress limit in kbps for packets matching this rule. 4 Click on Submit. Global VLAN Rules To configure VLAN rules: 1 Click on the Global VLAN Rules tab. The Global VLAN Rules screen appears. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Page 52
Priority specified above, Max – The packet's original priority will be replaced with the configured Priority only if the packet's original priority is greater than the configured Priority. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Page 53
Global Set Parameter Description Ingress Limit Specify the ingress limit in kbps for packets matching this rule. Egress Limit Specify the egress limit in kbps for packets matching this rule. 4 Click on Submit. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Noise Ratio settings for the selected ports. Reed Solomon Error Specify the upstream and downstream Correction Settings: Reed-Solomon delay. Delay Reed Solomon Error Specify the upstream and downstream Correction Settings: Reed-Solomon correction. Correction 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
1 From the home screen, click on the Circuit Summary button. The Circuit Summary screen appears. 2 Click on Refresh to view current information. Click on a port number in the leftmost column to view the Circuit Configuration screen. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
DSLAM, the modem at the remote end, and the copper cable pair connecting the two. Fixed Adaptive – The ports will automatically train up to the best possible speed, subject to a user-specified maximum upstream and downstream bandwidth. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Page 57
Specify whether the ports use Logical Link Control (LLC) or Virtual Channel Multiplexing (VCM) bridged encapsulation. These are defined in RFC 1483. Standard Mode Specify the ports’ DSL mode. 3 Click on Submit. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
DSCP's upper six bits will be utilized in considering a packet's DSCP type. Default is FC, indicating that all of the DSCP's upper six bits will be used in calculating the packet's DS Value. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Page 59
Priority. Ingress Limit Specify the ingress limit in kbps for packets matching this rule. Egress Limit Specify the egress limit in kbps for packets matching this rule. 3 Click on Submit. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
VLAN tag will be dropped. Untag indicates that ingress packets already matched to the IP Rule cannot have a VLAN tag to be further considered; packets with a VLAN tag will be dropped. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Page 61
Priority. Ingress Limit Specify the ingress limit in kbps for packets matching this rule. Egress Limit Specify the egress limit in kbps for packets matching this rule. 3 Click on Submit. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
VLAN tag will be dropped. Untag indicates that ingress packets already matched to the MAC Rule cannot have a VLAN tag to be further considered; packets with a VLAN tag will be dropped. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Page 63
Priority. Ingress Limit Specify the ingress limit in kbps for packets matching this rule. Egress Limit Specify the egress limit in kbps for packets matching this rule. 3 Click on Submit. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
ID. If it finds one it will use that rule, and then the packet will be checked for all other criteria. If it does not find a rule to match the packet VLAN ID the packet is dropped. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Page 65
Priority. Ingress Limit Specify the ingress limit in kbps for packets matching this rule. Egress Limit Specify the egress limit in kbps for packets matching this rule. 3 Click on Submit. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Backbone-VLAN function. A Backbone-VLAN tag cannot be used independently; stardard VLAN tags must be set. Additionally, the DSLAM uplink connection must run through a router in order for a Backbone VLAN tag to function. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Page 67
VLAN range) in addition to the uplink interface ports. Ethertype Specify the Ethertype of the backbone tag added to traffic if the backbone VLAN ID is configured. Used only in conjunction with backbone VLANs. 3 Click on Submit. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Configuration Using the NMS Port Statistics To view port statistics: 1 Click on the Port Statistics tab. The Port Statistics screen appears. 2 Click on Reset Statistics to set all statistics to zero. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
1 Click on Port Copy. The Port Copy screen appears. 2 Select a source port, then one or more destination ports. 3 Click on Submit. The configuration of the source port is copied to the destination port or ports. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Specify the upstream and downstream Correction Settings: Reed-Solomon correction. Correction EC/FDM Specify the upstream and downstream Echo Cancellation or Frequency Division Multiplexing mode. Fast Buffer Setting Specify the buffer setting: Fast or Interleave. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
1 From the home screen, click on the MAC-IGMP button. The MAC Summary screen appears. 2 Click on a Port or MIM button to see specific entries in the MAC table, or click on MAC Summary to see all entries. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Page 72
Specify an IGMP age interval, in seconds. This should be twice the query rate of your router. 6 To search for MAC or IGMP table entries, click on the Search tab. The Search screen appears. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
4900 Series DSLAM. This information is used to configure internal traffic flows. The screen is accessed using the blue button above the Ethernet uplinks on the schematic representation of the faceplate on the home page. Downlink Button 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Page 74
SFP connectors. The DSLAM Interconnect Configuration screen appears. 2 Select Off or a port from the drop-down list. For example, if this DSLAM is connected to a downstream DSLAM over the first MIM port, select MIMp1. 3 Click on Submit. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
2 Connect one end of a straight-through RJ45 to RJ45 Ethernet cable into the adapter plugged into your PC, and the other end of the cable into the COM port on the face of the DSLAM. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
[ALL, IP_ADDRESS [IP address]] CLEAR_NVRAM Clears Non-Volatile Random Access Memory, restoring the DSLAM to factory defaults. DISABLE_TELNET Disables access to the DSLAM using Telnet. DISABLE_TFTP Disables access to the DSLAM using Trivial File Transfer Protocol. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Page 77
Set and Show Command Items and Values (Sheet 1 of 3) Items Values ADSL_ENCAPSULATION [RFC1483-LLC,RFC1483-VCMUX] ADSL_PORT_MODE [ON,OFF,ADAPTIVE,FIXED_ADAPTIVE] ADSL_SPEED [XXXX YYYY] Where: XXXX = downstream rate (in kbps) and YYYY = upstream rate (in kbps) 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Page 78
None. You will be prompted for values. IGMP [dump,stop,snoop 225.1.1.2 123,clear] INBAND_MANAGEMENT [ON,OFF] INBAND_MGMT_VLAN_ID [0–4085] IP_ADDRESS xxx.xxx.xxx.xxx Value for IP_ADDRESS is a valid IP address. IP_RANGE SET: [1–4] SHOW: [ALL,1–4] LAYER2_ENABLE [on,off] Enables or disables Layer 2 functionality. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Page 79
Sets static mac addresses. SUBNET_MASK xxx.xxx.xxx.xxx SUPERUSER_PASSWORD None. You will be prompted for values. SYSTEM_NAME [system_name] Changes the DSLAM System Name and CLI Prompt. VLAN_RANGE VLAN_RANGE: SHOW: [ALL,1–10] SET: [1–10] VLAN_ID: [0–4085]–[0–4085] 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
1 inband_management on The DSLAM in this example can now be managed with NMS by attaching a PC to the DSLAM’s 10/100/1000 port and opening the address 137.182.10.251 in a web browser. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
1 Launch your MIB browser and perform any necessary program configurations. Refer to your MIB browser user manual for further information. 2 Download the MIBs from the Zhone website. Refer to your MIB browser user manual for instructions on how to compile the OIDs into your MIB browser.
SNMP Interface SNMP Community Strings The following are the default community strings for MIB access. SNMP Community String ACCESS COMMUNITY STRING* read only Password read/write Password *Community strings are case sensitive. 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
SFP Connector on page 85 10/100/1000BaseT Connector on page 86 DB9 to RJ45 Adapter Pinouts on page 87 Figure 2: 4929 DSLAM Front Panel DSL Ports and POTS Splitter Connectors The 50-pin RJ21X Telco connector labeled DSL Ports 1–24 provides the 2-wire loop interface from each DSL port to the demarcation point.
The 10/100/1000 port is an 8-pin unkeyed modular jack for a 10/100/ 1000BaseT interface. Table 7: 10/100/1000 Pinouts Signal Pin 8 Pin 1 Transmitted Data + 97-15449 Transmitted Data – Received Data + Unused Unused Received Data – Unused Unused 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
→ Transmit Data Receive Data ← Data Set Ready Request to Send ← Receive Data Transmit Data ↔ Ground GND Ground → Data Terminal Clear to Send Ready Pins not shown are unused. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Page 88
Connectors and Pin Assignments 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Width: 16.9″ (430 mm) without mounting brackets Depth: 9.5″ (241 mm) without cables Power The unit operates from a standard CO –48 VDC power supply. Dual feeds are supported. The terminal block accepts 28 to 18 AWG bare wire. 4929-A2-ZN20-30 4929 DSLAM Installation and User’s Guide...
Page 92
Standards and Enterprise MIBs Chassis and Module Identification, Configuration, Protocols Supported Multimedia Traffic Management Flash Upgradeable IEEE 802.3 IEEE 802.1p CoS IEEE 802.1Q VLAN IGMP Snooping (IGMPv1 and IGMPv2) Weight 2.5 lb (1.1 kg) 4929 DSLAM Installation and User’s Guide 4929-A2-ZN20-30...
Need help?
Do you have a question about the 4929 DSLAM and is the answer not in the manual?
Questions and answers