Installation Instructions; Safety Warnings For The Electrician; Air Inlet - AEG Electrolux DD8692-M Instruction Manual

Canopy hood
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 35
Instructions for use

Installation Instructions

Safety warnings for the electrician

Electrical connection
Voltage 230 V ~ Connect using:
a fixed power cable with a Schuko plug (European type) or
a fixed connection (by an authorised electrician).
Fixed connection
Where a fixed connection is necessary, an authorised electrician, registered with the
competent electrical authority, must carry out the work.
For the installation, a single-pole switch with a minimum distance between the contacts
of 3 mm must be used, to enable the appliance to be isolated from the mains.
This function can be carried out, for example, by using automatic circuit breaker switches,
fuses (the fuses should be removed from the fuse box), and contact breaker switches.
Safety Warnings for the kitchen fitter
Minimum Distance from the hob
When fitting the hood the following minimum distances from the upper edge of the cooking
hob to the lower edge of the hood must be respected:
-
electric hobs:
-
gas hobs:
-
coal /gas-oil cookers:
Air outlet
For the air outlet the following regulations must be observed:
The discharged air should not be directed into flues or outlet ducts for combustion gases.
It is not permitted to direct the discharged air into a duct that is used for ventilation of
areas in which combustion apparatus is installed.
In case of the discharged air being emitted into a flue or outlet duct for combustion
gases which is no longer used, it is recommended that you consult a competent heating
engineer first.
The hood can only operate at optimum efficiency if the following rules are respected:
-
use short straight sections for the outlet duct.
-
keep bends in the discharge ducting to a minimum.
-
do not use ducts with sharp curves, use slightly curved sections.
-
use large diameter ducts of large diameters where possible.
Non adherence to these basic rules will compromise hood performance and increase
the noise levels produced.

Air Inlet

A sufficiently large ventilation hole must be provided, of dimensions approximately equal
to the outlet hole.
40
650 mm
650 mm
700 mm